Inspection of Pitting Corrosions on Weld Overlay Cladding Using Uniform and Rotating Eddy Current Testing

被引:6
|
作者
Ge, Jiuhao [1 ,2 ,3 ]
Yu, Fanwei [3 ]
Tomizawa, Takuma [3 ]
Song, Haicheng [3 ]
Yusa, Noritaka [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Key Lab, Nondestruct Detect & Monitoring Technol High Spee, Minist Ind & Informat Technol, Nanjing 211106, Jiangsu, Peoples R China
[2] Tohoku Univ, Grad Sch Engn, JSPS Int Res, Sendai, Miyagi 9808579, Japan
[3] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Sendai, Miyagi 9808579, Japan
基金
中国国家自然科学基金;
关键词
Artificial pit; corrosion evaluation; reactor pressure vessel; rotating eddy current testing (RECT); CRACK DETECTION; SIGNALS; PROBE;
D O I
10.1109/TIM.2021.3108521
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study investigated the applicability of detecting pitting corrosions on stainless steel weld overlay cladding using uniform eddy current testing, which is insensitive to surface undulation, and rotating eddy current testing (RECT), which can be considered a superposition of uniform eddy current testing in orthogonal directions. The performance of the two techniques in detecting artificial pitting corrosions on and next to weld beads was compared. The signal distributions revealed that only RECT was capable of describing the surface profiles of pitting corrosions. The results of uniform eddy current testing could not distinguish between pitting corrosions and cracks. The probability of detection curves drawn to quantitatively indicate the detection capabilities of the two techniques revealed that uniform eddy current testing with induced eddy currents parallel and perpendicular to weld beads was better than RECT in detecting pitting corrosions on and next to weld beads, respectively. Scanning twice by uniform eddy current testing at orthogonal orientations may be a better process for detecting pitting corrosion on weld overlay cladding compared with using RECT. The measured signals of the two techniques in normal direction were located around the edges of the pitting corrosions, which only indicated the depth around edges. The results suggested that uniform eddy current testing and RECT with normal direction magnetic field signals may be inadequate for evaluating the maximum depth of pitting corrosions or large corrosions.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Rotating field eddy current (RoFEC)-probe for steam generator inspection
    Lei, Naiguang
    Udpa, Lalita
    Udpa, Satish
    Zeng, Zhiwei
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2010, 33 (3-4) : 1279 - 1285
  • [32] AUTOMATIC INSPECTION OF TUBES SCANNED BY A ROTATING EDDY-CURRENT PROBE
    MACLEOD, JES
    SIGNAL PROCESSING, 1983, 5 (05) : 445 - 450
  • [33] An optimization technique for the evaluation of eddy current inspection data to determine weld quality
    Hench, KW
    Christensen, W
    Lopez, AA
    Martin, C
    Phillips, TT
    INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOL 1-4, PROCEEDINGS, 2005, : 1535 - 1539
  • [34] Surface Profile Reconstruction of Complex Cracks Using the Signals of Rotating Eddy Current Testing Through the Eddy Current Imaging Method
    Ge, Jiuhao
    Hu, Baowang
    Yang, Chenkai
    Yu, Fanwei
    Yusa, Noritaka
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (09) : 9632 - 9641
  • [35] Hot wire inspection using eddy current
    Bae, JS
    Kim, SY
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 962 - 965
  • [36] Inspection of printed circuit by eddy-current testing techniques
    Yamada, S
    Iwahara, M
    Fujii, H
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION, 1997, 12 : 193 - 198
  • [37] Measurement of wall thinning through insulation with ferromagnetic cladding using pulsed eddy current testing
    Xu, Zhiyuan
    Wu, Xinjun
    Huang, Chen
    Kang, Yihua
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 426 - 429
  • [38] The potential for friction stir weld inspection using transient eddy currents
    Smith, RA
    INSIGHT, 2005, 47 (03) : 133 - 143
  • [39] The use of eddy current for ferritic weld testing in nuclear power plants
    Goldberg, L
    MATERIALS EVALUATION, 2003, 61 (12) : 1274 - 1278
  • [40] Recognition of INCONEL weld conductivity variation by means of eddy current testing
    Janousek, L
    Yusa, N
    Chen, Z
    Miya, K
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (VIII), 2004, 24 : 286 - 293