Multicatheter breast implant during breast conservative surgery: Novel approach to deliver accelerated partial breast irradiation

被引:13
|
作者
Cambeiro, Mauricio [1 ]
Martinez-Regueira, Fernando [2 ]
Rodriguez-Spiteri, Natalia [2 ]
Olartecoechea, Begona [3 ]
Pina Insausti, Luis [4 ]
Elizalde, Arlette [4 ]
Idoate Gastearena, Miguel [5 ]
Sola Gallego, Jesus [6 ]
Santisteban Eslava, Marta [1 ]
Manuel Aramendia, Jose [1 ]
Javier Aristu, Jose [1 ]
Arbea Moreno, Leire [1 ]
Moreno-Jimenez, Marta [1 ]
Valtuena, German [1 ]
Martinez-Monge, Rafael [1 ]
机构
[1] Univ Navarra, Dept Oncol, Pamplona, Spain
[2] Univ Navarra, Dept Gen Surg, Pamplona, Spain
[3] Univ Navarra, Dept Gynaecol, Pamplona, Spain
[4] Univ Navarra, Dept Radiol, Pamplona, Spain
[5] Univ Navarra, Dept Pathol, Pamplona, Spain
[6] Serv Riojano Salud, Dept Pathol, Logrono, Spain
关键词
Early breast cancer; Accelerated partial breast irradiation; Multicatheter breast implant; Intraoperative procedure; INTENSITY-MODULATED RADIOTHERAPY; EARLY POSTOPERATIVE OUTCOMES; DOSE-RATE BRACHYTHERAPY; PHASE-II TRIAL; TERM-FOLLOW-UP; RADIATION-THERAPY; INTRAOPERATIVE RADIOTHERAPY; CONSERVING SURGERY; UK STANDARDIZATION; SIMPLE MASTECTOMY;
D O I
10.1016/j.brachy.2016.03.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To assess the safety, feasibility, and efficacy of free-hand intraoperative multicatheter breast implant (FHIOMBI) and perioperative high-dose-rate brachytherapy (PHDRBT) in early breast cancer. METHODS AND MATERIALS: Patients with early breast cancer candidates for breast conservative surgery (BCS) were prospectively enrolled. Patients suitable for accelerated partial breast irradiation (APBI) (low or intermediate risk according GEC-ESTRO criteria) received PHDRBT (3.4 Gy BID x 10 in 5 days). Patients not suitable for APBI (high risk patients according GEC-ESTRO criteria) received PHDRBT boost (3.4 Gy BID x 4 in 2 days) followed by whole breast irradiation. RESULTS: From June 2007 to November 2014, 119 patients were treated and 122 FHIOMBI procedures were performed. Median duration of FHIOMBI was 25 minutes. A median of eight catheters (range, 4-14) were used. No severe intraoperative complications were observed. Severe early postoperative complications (bleeding) were documented in 2 patients (1.6%), wound healing complications in 3 (2.4%), and infection (mastitis or abscess) in 2 (1.6%). PHDRBT was delivered as APBI in 88 cases (72.1%) and as a boost in 34 (27.8%). The median clinical target volume T was 40.8 cc (range, 12.3-160.5); median D-90 was 3.32 Gy (range, 3.11-3.85); median dose homogeneity index was 0.72 (range, 0.48-0.82). With a median followup of 38.4 months (range, 8.7-98.7) no local, elsewhere, or regional relapses were observed; there was only one distant failure in PHDRBT boost. No major (acute or late) RTOG grade 3 or higher were documented in any of the 119 patients treated with PHDRBT. Cosmetic outcome in APBI patients was excellent or good in (87.0%) and fair or poor in (11.9%) while in boost patients was excellent or good in (76.4%) and fair in (23.5%). CONCLUSION: The FHIOMBI-PHDRBT program does not add complications to conservative surgery. It allows precise selection of APBI patients and offers excellent results in disease control and cosmetics. It also offers logistic advantages because it dramatically shortens the time of local treatment and avoids further invasive procedures. (C) 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:485 / 494
页数:10
相关论文
共 50 条
  • [31] Accelerated partial breast irradiation (apbi) with multicatheter brachytherapy (mcb): experience of a single institution
    Loessl, K.
    Cihoric, N.
    Isaak, B.
    Terribilini, D.
    Aebersold, D. M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (01) : 83 - 83
  • [32] Potential applicability of balloon catheter-based accelerated partial breast irradiation after conservative surgery for breast carcinoma
    Pawlik, TM
    Perry, A
    Strom, EA
    Babiera, GV
    Buchholz, TA
    Singletary, E
    Perkins, GH
    Ross, MI
    Schecter, NR
    Meric-Bernstam, F
    Ames, FC
    Hunt, KK
    Kuerer, HM
    CANCER, 2004, 100 (03) : 490 - 498
  • [33] Accelerated partial breast irradiation
    Chronowski, Gregory M.
    Buchholz, Thomas A.
    CURRENT PROBLEMS IN CANCER, 2007, 31 (01) : 7 - 25
  • [34] Accelerated Partial Breast Irradiation
    Alvarez, Carlos
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 209 (06) : 795 - 796
  • [35] Accelerated Partial Breast Irradiation
    Beitsch, Peter D.
    Shaitelman, Simona F.
    Vicini, Frank A.
    JOURNAL OF SURGICAL ONCOLOGY, 2011, 103 (04) : 362 - 368
  • [36] Accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy-A feasibility study
    Pohankova, Denisa
    Sirak, Igor
    Jandik, Pavel
    Kasaova, Linda
    Grepl, Jakub
    Motycka, Petr
    Asqar, Ahmed
    Paluska, Petr
    Ninger, Vladimir
    Bydzovska, Ivana
    Kopecky, Viliam
    Petera, Jiri
    BRACHYTHERAPY, 2018, 17 (06) : 949 - 955
  • [37] Accelerated partial breast irradiation
    David E.Wazer
    中国医学物理学杂志, 2002, (04) : 193 - 193
  • [38] Accelerated partial breast irradiation
    Yadav, Budhi Singh
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 161 - 161
  • [39] Correction to: Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
    Veronika Novotná
    Igor Sirák
    Denisa Pohanková
    Pavel Jandík
    Linda Kašaová
    Jakub Grepl
    Petr Paluska
    Petr Motyčka
    Ahmed Asqar
    Lucie Kretzler
    Jiří Petera
    Strahlentherapie und Onkologie, 2021, 197 : 461 - 462
  • [40] Toxicity and cosmetic outcome from multicatheter accelerated partial breast irradiation in early stage breast cancer patients.
    Bovi, J. A.
    Rownd, J.
    Lim, H. J.
    White, J.
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S203 - S203