Navigation for placement of scaphoid screws.: A new indication for intraoperative 3D navigation -: a cadaver study

被引:0
|
作者
Kendoff, D.
Citak, M.
Gaulke, R.
Gardner, M. J.
Geerling, J.
Krettek, C.
Huefner, T.
机构
[1] Hannover Med Sch, Unfallchirurg Klin, D-30625 Hannover, Germany
[2] Hosp Special Surg, Dept Orthopaed, New York, NY 10021 USA
来源
UNFALLCHIRURG | 2007年 / 110卷 / 09期
关键词
scaphoid screw; 3D navigation; computer-assisted surgery; reference tracker;
D O I
10.1007/s00113-007-1280-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Up to now, the use of navigation systems for the placement of scaphoid screws has been impossible, mainly because there have been no ways of fixing the reference markers. Faulty placement rates in internal fixation of the scaphoid show there is a current need for a 3D image-based navigation system and intraoperative monitoring of how successful the procedure will be. For this reason, we have developed a new radiotransparent hand fixation device (Scaph-Splint (R)), which allows reliable and accurate drilling of the scaphoid using 3D navigation. Tests of this device and the simultaneous precise placement of screws securing an internal fixation device are described in this paper. Material and Methods Relative movements between the wrist and fixation device were measured with a 3-D ultrasound motion analyser system. Five cadaveric upper extremity specimens were then used for further navigated test applications. Each specimen was placed in the fixation device, and both the forearm and hand were secured to the two surfaces, with the wrist in approximately 80 degrees of extension. A reference marker was then securely fixed to the fixation device. A commercial navigation system and 3-D fluoroscopic imaging were used for each trial. Under navigation, the scaphoid was drilled in retrograde fashion, and a screw was placed into the drilled hole. Following screw placement, a 3D scan was performed to evaluate its position. The screw placement was analysed blindly to optimal placement and drill or screw perforation, and the image quality was rated on a visual analog scale (VAS). Results There were few artefacts, and the image quality of the 3-D scan was judged as as good (VAS 7-9). Deviations of >= N0.2 mm between planned trajectory and drilling tunnal were not found in any of the specimens; there were deviations of >= 1 mm in one case, and all other cases showed deviations of >= 1 mm. There were no registration failures of the navigation system, indicating that no loosening of the reference marker or movement of the hand occurred. There was one case of scaphoid perforation at the distal pole. Discussion We found that the Scaph-Split allowed complete immobilisation of the hand and carpus. This allowed for adequate reference tracker stability and subsequent successful 3D navigated fluoroscopic drilling and screw placement in the scaphoid. While further tests on fresh-frozen cadavers is warranted, this technique may prove clinically to be very useful for surgeons treating scaphoid fractures.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 50 条
  • [1] Navigation for placement of scaphoid screws. A new indication for intraoperative 3D navigation - A cadaver study [Die navigierte scaphoidschraube. Eine neue indikation zur intraoperativen 3D-navigation - Eine kadaverstudie]
    Kendoff D.
    Citak M.
    Gaulke R.
    Gardner M.J.
    Geerling J.
    Krettek C.
    Hüfner T.
    [J]. Der Unfallchirurg, 2007, 110 (9): : 745 - 750
  • [2] A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine
    Hahn, Patrick
    Oezdemir, Semih
    Komp, Martin
    Giannakopoulos, Athanasios
    Heikenfeld, Roderich
    Kasch, Richard
    Merk, Harry
    Godolias, Georgios
    Ruetten, Sebastian
    [J]. PLOS ONE, 2015, 10 (07):
  • [3] Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation
    Liverneaux, Philippe A.
    Gherissi, Anes
    Stefanelli, Matthieu Beustes
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (02): : 165 - 173
  • [4] Intraoperative navigation assisted placement of percutaneous pedicle screws
    Upadhyaya, Cheerag D.
    Fewel, Matthew E.
    [J]. NEUROSURGICAL FOCUS, 2013, 35
  • [5] An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
    Chen, Xuanhuang
    Zheng, Feng
    Zhang, Guodong
    Gao, Xiaoqiang
    Wang, Ya
    Huang, Wenhua
    Lin, Haibin
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (22)
  • [6] Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study
    Hahn, Patrick
    Oezdemir, Semih
    Komp, Martin
    Giannakopoulos, Athanasios
    Kasch, Richard
    Merk, Harry
    Liermann, Dieter
    Godolias, Georgios
    Ruetten, Sebastian
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [7] Accuracy of fluoroscopic navigation of pedicle screws. Assessment of screw placement by computed tomography
    Fritsch, E
    Duchow, J
    Seil, R
    Grunwald, I
    Reith, W
    [J]. ORTHOPADE, 2002, 31 (04): : 385 - 391
  • [8] Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study
    Mueller, Marcus Christian
    Belei, Peter
    Pennekamp, Peter H.
    Kabir, Koroush
    Wirtz, Dieter C.
    Burger, Christof
    Weber, Oliver
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (07) : 1463 - 1469
  • [9] Comparison of 2D and 3D navigation techniques for percutaneous screw insertion into the scaphoid: Results of an experimental cadaver study
    Catala-Lehnen, Philip
    Nuechtern, Jakob V.
    Briem, Daniel
    Klink, Thorsten
    Rueger, Johannes M.
    Lehmann, Wolfgang
    [J]. COMPUTER AIDED SURGERY, 2011, 16 (06) : 280 - 287
  • [10] Is intraoperative 3-D Imaging without Navigation sufficiently secure for the Placement of cervical Pedicle Screws?
    Barann, Bastian
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2018, 156 (06): : 630 - 630