Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study

被引:29
|
作者
Mueller, Marcus Christian [1 ]
Belei, Peter [2 ]
Pennekamp, Peter H. [1 ]
Kabir, Koroush [1 ]
Wirtz, Dieter C. [1 ]
Burger, Christof [1 ]
Weber, Oliver [1 ]
机构
[1] Univ Hosp Bonn, Dept Orthopaed & Trauma Surg, D-53105 Bonn, Germany
[2] Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
关键词
FEMORAL-NECK FRACTURES; FLUOROSCOPY; FIXATION; REDUCTION; EXPOSURE; QUALITY;
D O I
10.1007/s00264-012-1496-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Medial femoral neck fractures are common, and closed reduction and internal fixation by three cannulated screws is an accepted method for the surgical treatment. Computer navigation for screw placement may reduce fluoroscopy time, the number of guidewire passes and optimise screw placement. In the context of a sawbone study, a computer-assisted planning and navigation system based on 3D-imaging for guidewire placement in the femoral neck was tested to improve screw placement. Three screws were inserted into 12, intact, femoral sawbones using the conventional technique and into 12, intact, femoral sawbones guided by the computer-based navigation system. Guidewire and subsequent screw placement in the femoral neck were evaluated. Use of the navigation system resulted in a significant reduction of the number of drilling attempts (p a parts per thousand currency signaEuro parts per thousand 0.05) and achieved optimised accuracy of implant placement by attaining significantly better screw parallelism (p a parts per thousand currency signaEuro parts per thousand 0.05) and significantly enlarged neck-width coverage by the three screws (p a parts per thousand currency signaEuro parts per thousand 0.0001). Computer assistance significantly increased the number of fluoroscopic images (p a parts per thousand currency signaEuro parts per thousand 0.001) and the operation time (p a parts per thousand currency signaEuro parts per thousand 0.0001). Three-dimensional computer-assisted navigation improves accuracy of cannulated screw placement in femoral neck while increasing the number of fluoroscopic images and operation time. Additional studies including fractured sawbones and cadaver models with the goal of reducing operation time are indispensable before introduction of this navigation system into clinical practice.
引用
收藏
页码:1463 / 1469
页数:7
相关论文
共 50 条
  • [1] Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study
    Marcus Christian Müller
    Peter Belei
    Peter H. Pennekamp
    Koroush Kabir
    Dieter C. Wirtz
    Christof Burger
    Oliver Weber
    International Orthopaedics, 2012, 36 : 1463 - 1469
  • [2] Safety of computer-assisted surgery for cannulated hip screws
    Hamelinck, H. K. M.
    Haagmans, M.
    Snoeren, M. M.
    Biert, J.
    van Vugt, A. B.
    Frolke, J. P. M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (455) : 241 - 245
  • [3] Three-dimensional accuracy of implant placement in a computer-assisted navigation system
    Chiu, Wai-kuen
    Luk, Wai-kuen
    Cheung, Lim-kwong
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (03) : 465 - 470
  • [4] Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    Richter, M
    Cakir, B
    Schmidt, R
    SPINE, 2005, 30 (20) : 2280 - 2287
  • [5] Computer-assisted three-dimensional phonograms
    NeuschaeferRube, C
    Klajman, S
    HNO, 1996, 44 (10) : 585 - 589
  • [6] Accuracy of Fluoroscopy Versus Computer-Assisted Navigation for the Placement of Anterior Cervical Pedicle Screws
    Patton, Andrew G.
    Morris, Randal P.
    Kuo, Yong-Fang
    Lindsey, Ronald W.
    SPINE, 2015, 40 (07) : E404 - E410
  • [7] The Computer-assisted Implementation of Three-dimensional Animation
    Ma Jingfeng
    Dong Haibo
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTOMATION, MECHANICAL CONTROL AND COMPUTATIONAL ENGINEERING, 2015, 124 : 603 - 609
  • [8] Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial
    Wang Jun-qiang
    Zhao Chun-peng
    Su Yong-gang
    Zhou Li
    Hu Lei
    Wang Tian-miao
    Wang Man-yi
    CHINESE MEDICAL JOURNAL, 2011, 124 (23) : 3906 - 3911
  • [9] Computer-assisted planning and simulation of hip operations using virtual three-dimensional models
    Handels, H
    Ehrhardt, J
    Plötz, W
    Pöppl, SJ
    MEDICAL INFORMATICS EUROPE '99, 1999, 68 : 686 - 689
  • [10] Computer-assisted analysis of three-dimensional MR angiograms
    Hernández-Hoyos, M
    Orkisz, M
    Puech, P
    Mansard-Desbleds, C
    Douek, P
    Magnin, IE
    RADIOGRAPHICS, 2002, 22 (02) : 421 - 436