Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study

被引:29
|
作者
Mueller, Marcus Christian [1 ]
Belei, Peter [2 ]
Pennekamp, Peter H. [1 ]
Kabir, Koroush [1 ]
Wirtz, Dieter C. [1 ]
Burger, Christof [1 ]
Weber, Oliver [1 ]
机构
[1] Univ Hosp Bonn, Dept Orthopaed & Trauma Surg, D-53105 Bonn, Germany
[2] Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
关键词
FEMORAL-NECK FRACTURES; FLUOROSCOPY; FIXATION; REDUCTION; EXPOSURE; QUALITY;
D O I
10.1007/s00264-012-1496-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Medial femoral neck fractures are common, and closed reduction and internal fixation by three cannulated screws is an accepted method for the surgical treatment. Computer navigation for screw placement may reduce fluoroscopy time, the number of guidewire passes and optimise screw placement. In the context of a sawbone study, a computer-assisted planning and navigation system based on 3D-imaging for guidewire placement in the femoral neck was tested to improve screw placement. Three screws were inserted into 12, intact, femoral sawbones using the conventional technique and into 12, intact, femoral sawbones guided by the computer-based navigation system. Guidewire and subsequent screw placement in the femoral neck were evaluated. Use of the navigation system resulted in a significant reduction of the number of drilling attempts (p a parts per thousand currency signaEuro parts per thousand 0.05) and achieved optimised accuracy of implant placement by attaining significantly better screw parallelism (p a parts per thousand currency signaEuro parts per thousand 0.05) and significantly enlarged neck-width coverage by the three screws (p a parts per thousand currency signaEuro parts per thousand 0.0001). Computer assistance significantly increased the number of fluoroscopic images (p a parts per thousand currency signaEuro parts per thousand 0.001) and the operation time (p a parts per thousand currency signaEuro parts per thousand 0.0001). Three-dimensional computer-assisted navigation improves accuracy of cannulated screw placement in femoral neck while increasing the number of fluoroscopic images and operation time. Additional studies including fractured sawbones and cadaver models with the goal of reducing operation time are indispensable before introduction of this navigation system into clinical practice.
引用
收藏
页码:1463 / 1469
页数:7
相关论文
共 50 条
  • [41] Poor usability of computer-assisted navigation for hip fracture surgery
    Rasmus Abildtrup Hestehave
    Per Hviid Gundtoft
    Christian Lind Nielsen
    Ole Brink
    Jan Duedal Rölfing
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 251 - 257
  • [42] Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty
    Beaumont, Eric
    Beaumont, Pierre
    Odermat, Daniel
    Fontaine, Isabelle
    Jansen, Herbert
    Prince, Francois
    ADVANCES IN ORTHOPEDICS, 2011, 2011
  • [43] Poor usability of computer-assisted navigation for hip fracture surgery
    Hestehave, Rasmus Abildtrup
    Gundtoft, Per Hviid
    Nielsen, Christian Lind
    Brink, Ole
    Rolfing, Jan Duedal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 251 - 257
  • [44] Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty
    Pitto, R. P.
    Malak, S.
    Anderson, I. A.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 391 - 395
  • [46] Three-dimensional computer-assisted design of plastic reconstructive surgery procedures
    Department of Plastic and Reconstructive Surgery, IST, United States
    不详
    不详
    不详
    Stud. Health Technol. Informatics, (134-138):
  • [47] Three-dimensional Computer-assisted Modeling of Talus Morphology in Chinese Patients
    He, Jin-quan
    Ma, Xin-long
    Zhang, Xi
    Xin, Jing-yi
    Li, Nan
    ORTHOPAEDIC SURGERY, 2016, 8 (03) : 383 - 392
  • [48] Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty
    R. P. Pitto
    S. Malak
    I. A. Anderson
    International Orthopaedics, 2009, 33
  • [49] Limitations of Imageless Computer-Assisted Navigation for Total Hip Arthroplasty
    Lin, Fang
    Lim, Dohyung
    Wixson, Richard L.
    Milos, Steven
    Hendrix, Ronald W.
    Makhsous, Mohsen
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 596 - 605
  • [50] Computer-assisted navigation in Birmingham hip resurfacing: A case report
    Shah, Ritesh
    Benson, Jessica R.
    Muir, Jeffrey M.
    SAGE OPEN MEDICAL CASE REPORTS, 2018, 6