Experimental benchmark of the NINJA code for application to the Linac4 H-ion source plasma

被引:10
|
作者
Briefi, S. [1 ]
Mattei, S. [2 ,3 ]
Rauner, D. [1 ,4 ]
Lettry, J. [2 ]
Tran, M. Q. [3 ]
Fantz, U. [1 ,4 ]
机构
[1] Univ Augsburg, AG Expt Plasmaphys, D-86135 Augsburg, Germany
[2] CERN, CH-1211 Geneva 23, Switzerland
[3] Ecole Polytech Fed Lausanne, Swiss Plasma Ctr, Stn 13, CH-1015 Lausanne, Switzerland
[4] Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
来源
NEW JOURNAL OF PHYSICS | 2017年 / 19卷
关键词
negative hydrogen ion sources for accelerators; benchmark of PIC code; OES measurements; HYDROGEN MOLECULES; STATES; TEMPERATURE; POPULATION; EXCITATION; DISCHARGES; H-2;
D O I
10.1088/1367-2630/aa8679
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For a dedicated performance optimization of negative hydrogen ion sources applied at particle accelerators, a detailed assessment of the plasma processes is required. Due to the compact design of these sources, diagnostic access is typically limited to optical emission spectroscopy yielding only line-of-sight integrated results. In order to allow for a spatially resolved investigation, the electromagnetic particle-in-cell Monte Carlo collision code NINJA has been developed for the Linac4 ion source at CERN. This code considers the RF field generated by the ICP coil as well as the external static magnetic fields and calculates self-consistently the resulting discharge properties. NINJA is benchmarked at the diagnostically well accessible lab experiment CHARLIE Concept studies forHelicon Assisted RF Low pressure Ion sourcEs) at varying RF power and gas pressure. A good general agreement is observed between experiment and simulation although the simulated electron density trends for varying pressure and power as well as the absolute electron temperature values deviate slightly from the measured ones. This can be explained by the assumption of strong inductive coupling in NINJA, whereas the CHARLIE discharges show the characteristics of loosely coupled plasmas. For the Linac4 plasma, this assumption is valid. Accordingly, both the absolute values of the accessible plasma parameters and their trends for varying RF power agree well in measurement and simulation. At varying RF power, the H- current extracted from the Linac4 source peaks at 40. kW. For volume operation, this is perfectly reflected by assessing the processes in front of the extraction aperture based on the simulation results where the highest H- density is obtained for the same power level. In surface operation, the production of negative hydrogen ions at the converter surface can only be considered by specialized beam formation codes, which require plasma parameters as input. It has been demonstrated that this input can be provided reliably by the NINJA code.
引用
收藏
页数:16
相关论文
共 48 条
  • [41] Numerical Analysis of Electron Energy Distribution Function and Its Effects on the H- Production in Linac4 H- Source
    Mochizuki, Shintaro
    Mattei, Stefano
    Nishida, Kenjiro
    Hatayama, Akiyoshi
    Lettry, Jacques
    PLASMA AND FUSION RESEARCH, 2016, 11
  • [42] Application of Optical Emission Spectroscopy for the SNS H- Ion Source Plasma Studies
    Han, B. X.
    Stockli, M. P.
    Welton, R. F.
    Murray, S. N., Jr.
    Pennisi, T. R.
    Santana, M.
    FOURTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2014), 2015, 1655
  • [43] Laser ion source: A direct plasma injection scheme for two-beam type interdigital-H radio frequency quadrupole linac
    Ishibashi, T.
    Hayashizaki, N.
    Tamura, J.
    Oka, K.
    Shimaya, Y.
    Hattori, T.
    Kashiwagi, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [44] GENERATION OF H-, D- IONS ON COMPOSITE SURFACES WITH APPLICATION TO SURFACE PLASMA ION-SOURCE SYSTEMS
    HISKES, JR
    KARO, AM
    WIMMER, E
    FREEMAN, AJ
    CHUBB, SR
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1984, 2 (02): : 670 - 674
  • [45] A STUDY OF THE RELATIONSHIP BETWEEN WEAR RATE AND NITROGEN CONCENTRATION PROFILE AND APPLICATION TO PLASMA SOURCE ION-IMPLANTED TI-6AL-4V ALLOY
    CHEN, A
    BLANCHARD, J
    CONRAD, JR
    FETHERSTON, P
    QIU, X
    WEAR, 1993, 165 (01) : 97 - 101
  • [46] Investigation of diamond-like carbon formed on PET film by plasma-source ion implantation using C2H2 and CH4
    Yoshida, M
    Watanabe, S
    Tanaka, T
    Takagi, T
    Shinohara, M
    Lee, JW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 206 : 712 - 716
  • [47] Experimental and Theoretical Studies of the Pyrazoline Derivative 5-(4-methylphenyl)-3-(5-methylfuran-2-yl)-1-phenyl-4,5-dihydro-1H-Pyrazole and its Application for Selective Detection of Cd2+ ion as Fluorescent Sensor
    Promila Sharma
    Shikha Bhogal
    Asnake Lealam
    Sandeep Kumar
    Mohamad Yusuf
    Ashok Kumar Malik
    Journal of Fluorescence, 2022, 32 : 969 - 981
  • [48] Experimental and Theoretical Studies of the Pyrazoline Derivative 5-(4-methylphenyl)-3-(5-methylfuran-2-yl)-1-phenyl-4,5-dihydro-1H-Pyrazole and its Application for Selective Detection of Cd2+ ion as Fluorescent Sensor
    Sharma, Promila
    Bhogal, Shikha
    Lealam, Asnake
    Kumar, Sandeep
    Yusuf, Mohamad
    Malik, Ashok Kumar
    JOURNAL OF FLUORESCENCE, 2022, 32 (03) : 969 - 981