A microfluidic impedance biosensor based on immunomagnetic separation and urease catalysis for continuous-flow detection of E-coli O157:H7

被引:69
|
作者
Yao, Lan [1 ]
Wang, Lei [2 ]
Huang, Fengchun [2 ]
Cai, Gaozhe [2 ]
Xi, Xinge [3 ]
Lin, Jianhan [1 ,2 ]
机构
[1] China Agr Univ, Key Lab Agr Informat Acquisit Technol, Minist Agr, Beijing 100083, Peoples R China
[2] China Agr Univ, Key Lab Modern Precis Agr Syst Integrat Res, Minist Educ, Beijing 100083, Peoples R China
[3] Univ Arkansas, Dept Biol & Agr Engn, Fayetteville, AR 72701 USA
关键词
Impedance biosensor; Impedance normalization; Continuous-flow detection; Immunomagenatic separation; Urease catalysis; RAPID DETECTION; MAGNETIC NANOPARTICLES; SIGNAL AMPLIFICATION; SENSITIVE DETECTION; IMMUNOSENSOR; MICROELECTRODE; SAMPLES; SYSTEM;
D O I
10.1016/j.snb.2017.12.110
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Early screening of foodborne pathogens is a key to control the outbreaks of foodborne illnesses. In this study, a microfluidic impedance biosensor combined with the immune magnetic nanoparticles (MNPs) for bacteria separation, the urease for biological signal amplification and the microfluidic chip for impedance measurement was developed for rapid, sensitive and continuous-flow detection of E. coli O157:H7. After the streptavidin modified MNPs were conjugated with the biotinylated polyclonal antibodies (PAbs) to form the immune MNPs, the target bacteria was first separated by the MNPs from the background to form the MNP-bacteria complexes. Then, the gold nanoparticles (GNPs) modified with the urease and the aptamers against E. coli O157:H7 were conjugated with the MNP-bacteria to form the MNP-bacteria-GNP-urease complexes. Finally, the complexes were used to catalyze the hydrolysis of urea into ammonium carbonate, leading to the decrease in the impedance. The impedance was online measured by this proposed biosensor and analyzed using the impedance normalization to determine the concentration of E. coli O157:H7. A good linear relationship between the impedance relative change rate of the catalysate and the concentration of the bacteria was obtained with low detection limit of 12 CFU/mL. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1013 / 1021
页数:9
相关论文
共 50 条
  • [41] The biocontrol of E-coli O157:H7 at farm level
    McGee, P
    Sheridan, JJ
    Earley, B
    Leonard, N
    [J]. FOOD SAFETY ASSURANCE IN THE PRE-HARVEST PHASE, VOL 1: FOOD SAFETY ASSURANCE AND VETERINARY PUBLIC HEALTH, 2002, : 309 - 310
  • [42] Detection of E-coli O157:H7 DNA by a Novel QCM Biosensor coupled with Gold Nanoparticles Amplification
    Wang, Lijiang
    Wei, Qingshan
    Wu, Chunsheng
    Ji, Jian
    Liu, Qingjun
    Yang, Mo
    Wang, Ping
    [J]. 2007 7TH IEEE CONFERENCE ON NANOTECHNOLOGY, VOL 1-3, 2007, : 330 - +
  • [43] An anti E-coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E-coli)
    Zhang, J
    Ji, HF
    [J]. ANALYTICAL SCIENCES, 2004, 20 (04) : 585 - 587
  • [44] Direct detection of E-Coli O157:H7 in selected food systems by a surface plasmon resonance biosensor
    Waswa, John
    Irudayaraj, Joseph
    DebRoy, Chitrita
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2007, 40 (02) : 187 - 192
  • [45] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [46] Immunomagnetic-electrochemiluminescent detection of E.coli O157:H7 in ground beef
    Crawford, CG
    Wijey, C
    Fratamico, P
    Tu, SI
    Brewster, J
    [J]. JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2000, 8 (04): : 249 - 264
  • [47] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [48] Detection of Escherichia coli O157 in French food samples using an immunomagnetic separation method and the VIDAS™ E-coli O157
    Vernozy-Rozand, C
    Mazuy, C
    Ray-Gueniot, S
    Boutrand-Loei, S
    Meyrand, A
    Richard, Y
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1997, 25 (06) : 442 - 446
  • [49] Improvement of Immunomagnetic separation for Escherichia coli O157:H7 detection by the PickPen magnetic particle separation device
    Nou, Xiangwu
    Arthur, Terrance M.
    Bosilevac, Joseph M.
    Brichta-Harhay, Dayna M.
    Guerini, Michael N.
    Kalchayanand, Norasak
    Koohmaraie, Mohammad
    [J]. JOURNAL OF FOOD PROTECTION, 2006, 69 (12) : 2870 - 2874
  • [50] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (03): : 309 - 316