A comparison of accurate automatic hippocampal segmentation methods

被引:30
|
作者
Zandifar, Azar [1 ,2 ]
Fonov, Vladimir [1 ]
Coupe, Pierrick [3 ]
Pruessner, Jens [4 ]
Collins, D. Louis [1 ,2 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[3] Univ Bordeaux, LaBRI, UMR 5800, PICTURA, F-33400 Talence, France
[4] McGill Univ, Res Ctr Studies Aging, Montreal, PQ, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会; 加拿大创新基金会; 美国国家卫生研究院;
关键词
Hippocampal segmentation; Alzheimer's disease; Dice's kappa; Cohen's d; Area under receiver operating characteristic curve; MULTI-ATLAS SEGMENTATION; ALZHEIMERS-DISEASE; LABEL FUSION; MR-IMAGES; AMYGDALA; REGISTRATION; VALIDATION; ATROPHY; VOLUME; CLASSIFICATION;
D O I
10.1016/j.neuroimage.2017.04.018
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The hippocampus is one of the first brain structures affected by Alzheimer's disease (AD). While many automatic methods for hippocampal segmentation exist, few studies have compared them on the same data. In this study, we compare four fully automated hippocampal segmentation methods in terms of their conformity with manual segmentation and their ability to be used as an AD biomarker in clinical settings. We also apply error correction to the four automatic segmentation methods, and complete a comprehensive validation to investigate differences between the methods. The effect size and classification performance is measured for AD versus normal control (NC) groups and for stable mild cognitive impairment (sMCI) versus progressive mild cognitive impairment (pMCI) groups. Our study shows that the nonlinear patch-based segmentation method with error correction is the most accurate automatic segmentation method and yields the most conformity with manual segmentation (kappa = 0.894). The largest effect size between AD versus NC and sMCI versus pMCI is produced by FreeSurfer with error correction. We further show that, using only hippocampal volume, age, and sex as features, the area under the receiver operating characteristic curve reaches up to 0.8813 for AD versus NC and 0.6451 for sMCI versus pMCI. However, the automatic segmentation methods are not significantly different in their performance.
引用
收藏
页码:383 / 393
页数:11
相关论文
共 50 条
  • [1] COMPARISON OF MANUAL AND AUTOMATIC METHODS OF HIPPOCAMPUS SEGMENTATION
    Bartecek, R.
    van Haren, N. E. M.
    Koolschijn, P. C. M. P.
    Pol, H. E. Hulshoff
    Kahn, R. S.
    [J]. EUROPEAN PSYCHIATRY, 2011, 26
  • [2] Comparison of segmentation methods for automatic diagnosis of dermoscopy images
    Mendonca, Teresa
    Marcal, Andre R. S.
    Vieira, Angela
    Nascimento, Jacinto C.
    Silveira, Margarida
    Marques, Jorge S.
    Rozeira, Jorge
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 6573 - +
  • [3] Comparison of Automatic Blood Vessel Segmentation Methods in Retinal Images
    Maruthusivarani, M.
    Ramakrishnan, T.
    Santhi, D.
    Muthukkutti, K.
    [J]. 2013 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN VLSI, EMBEDDED SYSTEM, NANO ELECTRONICS AND TELECOMMUNICATION SYSTEM (ICEVENT 2013), 2013,
  • [4] Automatic moving object segmentation with accurate boundaries
    Wang, J
    Wang, HF
    Liu, QS
    Lu, HQ
    [J]. COMPUTER VISION - ACCV 2006, PT I, 2006, 3851 : 276 - 285
  • [5] Comparison of Automated and Manual Hippocampal Segmentation
    Chow, Nicole
    Green, Amity
    Hwang, Kristy
    Jack, Clifford
    Thompson, Paul
    Apostolova, Liana
    [J]. NEUROLOGY, 2012, 78
  • [6] Accuracy and bias of automatic hippocampal segmentation in children and adolescents
    Annika Herten
    Kerstin Konrad
    Helga Krinzinger
    Jochen Seitz
    Georg G. von Polier
    [J]. Brain Structure and Function, 2019, 224 : 795 - 810
  • [7] Accuracy and bias of automatic hippocampal segmentation in children and adolescents
    Herten, Annika
    Konrad, Kerstin
    Krinzinger, Helga
    Seitz, Jochen
    von Polier, Georg G.
    [J]. BRAIN STRUCTURE & FUNCTION, 2019, 224 (02): : 795 - 810
  • [8] Evaluation and Comparison of Automatic Brain Segmentation Methods Based On the Gold Standard Method
    Zamanpour S.A.
    Ganji Z.
    Bigham B.
    Zemorshidi F.
    Zare H.
    [J]. Iranian Journal of Medical Physics, 2023, 20 (04) : 233 - 245
  • [9] Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
    Queiroz, Polyane Mazucatto
    Rovaris, Karla
    Santaella, Gustavo Machado
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (06) : 674 - 679
  • [10] Comparison of automatic segmentation methods on multicenter PET images for tumor volume definition
    de Brouwer, Thomas
    Vanderlinden, Bruno
    Guiot, Thomas
    Garcia, Camilo
    Flamen, Patrick
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53