RADIATION DOSE AND IMAGE QUALITY FOR ADULT INTERVENTIONAL CARDIOLOGY IN CHILE: A NATIONAL SURVEY

被引:7
|
作者
Ubeda, C. [1 ,2 ]
Vano, E. [3 ,4 ]
Miranda, P. [5 ]
Leyton, F. [6 ,7 ]
Valenzuela, E. [8 ]
Oyarzun, C. [9 ]
机构
[1] Tarapaca Univ, Fac Hlth Sci, Dept Clin Sci, Arica, Chile
[2] Tarapaca Univ, CIHDE, Arica, Chile
[3] Univ Complutense, Dept Radiol, E-28040 Madrid, Spain
[4] San Carlos Hosp, Madrid 28040, Spain
[5] Hosp Ninos Luis Calvo Mackenna, Hemodynam Dept, Cardiovasc Serv, Santiago, Chile
[6] Diego Portales Univ, Inst Publ Hlth Chile, Santiago, Chile
[7] Diego Portales Univ, Fac Med, Santiago, Chile
[8] Catholic Univ Hosp Clin, Ctr Diag & Endovasc Therapy, Santiago, Chile
[9] Comis Chilena Energia Nucl, Santiago, Chile
关键词
CARDIAC-CATHETERIZATION;
D O I
10.1093/rpd/ncr276
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this work was to investigate the differences in dose settings and image quality among 10 X-ray systems used for interventional cardiology in Chile. Entrance surface air kerma (ESAK) was measured on a phantom of 20 cm thickness of polymethyl methacrylate slabs. Image quality was evaluated using DICOM images of a test object Leeds TOR 18-FG for cine mode acquisition, through the numerical parameters signal-to-noise ratio (SNR), high-contrast spatial resolution (HCSR) and figure of merit. ESAK rate values for fluoroscopy modes ranged between 7.1 and 121.7 mGy min(-1). For cine mode, ESAK values per frame ranged from 63 to 400 mu Gy fr(-1). SNR and HCSR parameters for cine mode varied from 4.8 to 8.6 and 0.4 to 10, respectively. FOM values resulted from 6.9 to 64.5 among the different X-ray systems. Results show important differences between systems and point out the need to launch an optimisation programme.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 50 条
  • [1] RADIATION DOSE AND IMAGE QUALITY FOR PAEDIATRIC INTERVENTIONAL CARDIOLOGY SYSTEMS. A NATIONAL SURVEY IN CHILE
    Ubeda, Carlos
    Vano, Eliseo
    Miranda, Patricia
    Leyton, Fernando
    Carlos Martinez, Luis
    Oyarzun, Carlos
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 429 - 438
  • [2] Radiation dose and image quality for paediatric interventional cardiology
    Vano, E.
    Ubeda, C.
    Leyton, F.
    Miranda, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15): : 4049 - 4062
  • [3] EVOLUTION OF RADIATION DOSE AND IMAGE QUALITY IN A PEDIATRIC INTERVENTIONAL CARDIOLOGY SYSTEM
    Ubeda, Carlos
    Miranda, Patricia
    Dalmazzo, Dandaro
    [J]. INTERCIENCIA, 2014, 39 (07) : 518 - 523
  • [4] National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan
    Lin, Chung-Jung
    Mok, Greta S. P.
    Tsai, Mang-Fen
    Tsai, Wei-Ta
    Yang, Bang-Hung
    Tu, Chun-Yuan
    Wu, Tung-Hsin
    [J]. PLOS ONE, 2015, 10 (06):
  • [5] OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE
    Ubeda, Carlos
    Morales, Claudio
    Gutierrez, Diego
    Oliveira, Marcus
    Manterola, Carlos
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 294 - 297
  • [6] Radiation dose to the heart in paediatric interventional cardiology
    Keiller, D. A.
    Martin, C. J.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (02) : 257 - 264
  • [7] Nationwide survey of fluoroscopy: Radiation dose and image quality
    Suleiman, OH
    Conway, BJ
    Quinn, P
    Antonsen, RG
    Rueter, FG
    Slayton, RJ
    Spelic, DC
    [J]. RADIOLOGY, 1997, 203 (02) : 471 - 476
  • [8] CT Image Quality and Radiation Dose Survey in Taiwan
    Tsai, H. Y.
    Liu, H. L.
    Chen, C. C.
    Hwang, Y. S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose
    Livingstone, Roshan S.
    Chase, David
    Varghese, Anna
    George, Paul V.
    George, Oommen K.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 24 - 28
  • [10] A NATIONAL PROGRAMME FOR PATIENT AND STAFF DOSE MONITORING IN INTERVENTIONAL CARDIOLOGY
    Sanchez, R.
    Vano, E.
    Fernandez, J. M.
    Sotil, J.
    Carrera, F.
    Armas, J.
    Rosales, F.
    Pifarre, X.
    Escaned, J.
    Angel, J.
    Diaz, J. F.
    Bosa, F.
    Saez, J. R.
    Goicolea, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 57 - 61