Basic Experiments on Measurement of Salinity using a Heterodyne Double-pass Interferometer

被引:0
|
作者
Asakawa, Kenichi [1 ]
Ishihara, Yasuhisa [1 ]
Araya, Akito [2 ]
机构
[1] Japan Agcy Marine Earth Sci & Technol, Marine Technol & Engn Ctr, Yokosuka, Kanagawa, Japan
[2] Univ Tokyo, Earthquake Res Inst, Bunkyo Ku, Tokyo, Japan
关键词
salinity; heterodyne double-pass interferometer; Zeeman effect; HeNe laser; ocean environment; REFRACTOMETER;
D O I
暂无
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
We propose a new method to measure the salinity of seawater using a heterodyne double-pass interferometer. Results of preliminary experiments show that the effect of the temperature was reduced by about one order of magnitude when compared with Michelson interferometer. The measured phase difference between pure water and 3.5 parts per thousand salt water of 182.0 degrees was slightly higher than that of the theoretically expected value of 176.0 degrees. The possible cause of this error is discussed in this paper.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Double-pass measurement of human eye aberrations: limitations and practical realization
    Letfullin, R
    Belyakov, A
    Cherezova, T
    Kudryashov, A
    OPTICS IN ATMOSPHERIC PROPAGATION AND ADAPTIVE SYSTEMS VII, 2004, 5572 : 340 - 348
  • [32] Displacement measurement of an indentation tester using heterodyne interferometer
    Hattori, K
    Takagi, S
    Seino, Y
    Nakano, H
    JOINT INTERNATIONAL CONFERENCE IMEKO TC3/TC5/TC20, 2002, 1685 : 477 - 480
  • [33] Magnetometry via a double-pass continuous quantum measurement of atomic spin
    Chase, Bradley A.
    Baragiola, Ben Q.
    Partner, Heather L.
    Black, Brigette D.
    Geremia, J. M.
    PHYSICAL REVIEW A, 2009, 79 (06):
  • [34] Flying height measurement of magnetic disk using double common-path heterodyne interferometer
    Lin, D. J.
    Yue, Z. Y.
    Song, N. H.
    Meng, Y. G.
    Yin, C. Y.
    4TH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY (ISIST' 2006), 2006, 48 : 750 - 754
  • [35] The measurement error induced by intensity scintillation for single-pass and double-pass imaging polarimetry
    Yao, Benxi
    Gu, Naiting
    Rao, Changhui
    OPTIK, 2018, 170 : 95 - 100
  • [36] Average double-pass ocular diattenuation using foveal fixation
    Bueno, Juan M.
    Artal, Pablo
    JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) : 849 - 859
  • [37] Refractive Index and Temperature Sensor Based on Double-Pass M-Z Interferometer With an FBG
    Lu, Yanfang
    Shen, Changyu
    Zhong, Chuan
    Chen, Debao
    Dong, Xinyong
    Cai, Jinhui
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (11) : 1124 - 1127
  • [38] Using a Double-pass solar drier for drying of bamboo shoots
    Banout, Jan
    Ehl, Petr
    JOURNAL OF AGRICULTURE AND RURAL DEVELOPMENT IN THE TROPICS AND SUBTROPICS, 2010, 111 (02) : 119 - 127
  • [39] Multi-wavelength Er-Yb-doped fibre ring laser using a double-pass Mach-Zehnder interferometer with a Sagnac interferometer
    Filoteo-Razo, J. D.
    Hernandez-Garcia, J. C.
    Estudillo-Ayala, J. M.
    Pottiez, O.
    Jauregui-Vazquez, D.
    Sierra-Hernandez, J. M.
    Lauterio-Cruz, J. P.
    Carrillo-Delgado, C. M.
    Rojas-Laguna, R.
    OPTICS AND LASER TECHNOLOGY, 2021, 139
  • [40] Odd Aberration in Double-Pass Human Eye's Aberration Measurement System
    Deng Yangchun
    Zhao Junlei
    Dai Yun
    Zhang Yudong
    ACTA OPTICA SINICA, 2018, 38 (08)