Durability testing of components for the Jarvik 2000 completely implantable axial flow left ventricular assist device

被引:10
|
作者
Marlinski, E [1 ]
Jacobs, G [1 ]
Deirmengian, C [1 ]
Jarvik, R [1 ]
机构
[1] Transicoil Med LLC, Norristown, PA 19403 USA
关键词
D O I
10.1097/00002480-199809000-00090
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cable-lead tester and real time bearing tester have been developed with provisions to test future implantable electronics, transcutaneous energy transfer system (TETS), and related interconnect cabling designs. The cable/lead tester, used in 1997 to test a previously considered implantable bellows-connector-cabling system, can test up to 10 samples at a time. X-Y-Z-theta motions are applied to the proximal end of the test specimen with its distal end fixed. The real time bearing tester is of a mock loop configuration with the bearings under test housed in a fully functional, Good Manufacturing Practices assembled axial pump. A simulated left ventricular pulsatile preload is applied to the inflow of the axial pump, while its outflow is subjected to an 80 mmHg aortic afterload by pumping into a fixed height tube with no outflow restriction. The heated blood bath saline used in this system is UV sterilized and mechanically filtered by use of a commercial salt water conditioning system attached external to the main preload fluid reservoir. The cable-lead tester and real time bearing tester design include provisions to house a complete Jarvik 2000 left ventricular assist device (Transicoil Medical, Norristown, PA) for in vitro system testing.
引用
收藏
页码:M741 / M744
页数:4
相关论文
共 50 条
  • [21] Use of the Jarvik 2000 continuous flow left ventricular assist device for acute myocardial infarction and cardiogenic shock
    Selzman, Craig H.
    Chang, Patricia P.
    Vernon-Platt, Tracy
    Bowen, Amanda
    Kowalczyk, Scott
    Sheridan, Brett C.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (07): : 756 - 758
  • [22] Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass
    Frazier, OH
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (03): : 1028 - 1030
  • [23] The Jarvik 2000 is associated with less infections than the HeartMate left ventricular assist device
    Siegenthaler, MP
    Martin, J
    Pernice, K
    Doenst, T
    Sorg, S
    Trummer, G
    Friesewinkel, O
    Beyersdorf, F
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (05) : 748 - 755
  • [24] Capsule endoscopy in the detection of small-intestinal bleeding in patients supported by a nonpulsatile axial-flow Jarvik 2000 left ventricular assist device
    Seow, CH
    Zimmerman, MJ
    [J]. GASTROINTESTINAL ENDOSCOPY, 2006, 63 (07) : 1087 - 1087
  • [25] Implantation of the permanent Jarvik-2000 left-ventricular-assist-device: surgical technique
    Siegenthaler, MP
    Martin, J
    Frazier, OH
    Beyersdorf, F
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (03) : 546 - 548
  • [26] Repeated Successful Thrombolysis of a Jarvik 2000 Left Ventricular Assist Device in a Patient With Noncompaction Cardiomyopathy
    Ninios, Vlasis
    Visouli, Aikaterini
    Pitsis, Antonis
    [J]. CIRCULATION, 2010, 121 (03) : E13 - E14
  • [27] Direct thrombolytic therapy for intraventricular thrombosis in patients with the Jarvik 2000 left ventricular assist device
    Delgado, R
    Frazier, OH
    Myers, TJ
    Gregoric, ID
    Robertson, K
    Shah, NA
    Kar, B
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : 231 - 233
  • [28] Late de novo aortic regurgitation with the Jarvik 2000 Flowmaker® left ventricular assist device
    Rossi, Michele
    Serraino, Giuseppe Filiberto
    Jiritano, Federica
    Renzulli, Attilio
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2012, 35 (12): : 1080 - 1082
  • [29] Long-term animal survival with an implantable axial flow pump as a left ventricular assist device
    Konishi, H
    Antaki, JF
    Litwak, P
    Kameneva, M
    Yamazaki, K
    Macha, M
    Kerrigan, TP
    Mandarino, WA
    Butler, KC
    Borovetz, TS
    Kormos, RL
    [J]. ARTIFICIAL ORGANS, 1996, 20 (02) : 124 - 127
  • [30] Use of the Jarvik 2000 to facilitate left ventricular assist device placement in challenging apex anatomy
    Bejko, Jonida
    Tarzia, Vincenzo
    Gerosa, Gino
    Bottio, Tomaso
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (08): : 1049 - 1051