Sensor-Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy

被引:11
|
作者
Doering, Michael [1 ]
Sommer, Philipp [1 ]
Rolf, Sascha [1 ]
Lucas, Johannes [1 ]
Breithardt, Ole A. [1 ]
Hindricks, Gerhard [1 ]
Richter, Sergio [1 ]
机构
[1] Univ Leipzig, Ctr Heart, Dept Electrophysiol, D-04289 Leipzig, Germany
关键词
cardiac resynchronization therapy; electromagnetic navigation; heart failure; lead position; radiation exposure; ATRIAL-FIBRILLATION; RADIATION-EXPOSURE; TASK-FORCE; EXPERIENCE; SYSTEM; PATIENT; TECHNOLOGY; PHYSICIAN; ABLATION; IMAGE;
D O I
10.1111/jce.12550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Electromagnetic Navigation for CRT Implantation IntroductionImplantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real-time 3-D location of sensor-embedded delivery tools superimposed on prerecorded X-ray cine-loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and ResultsBetween January 2012 and December 2013, 71 consecutive patients (69 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 +/- 37 minutes and the median total fluoroscopy time (skin-to-skin) was 4.9 (2.5-7.8) minutes with a median dose-area-product of 476 (260-1056) cGy*cm(2). An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm(2), respectively (P = 0.044 ). ConclusionUse of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 50 条
  • [1] Sensor-based electromagnetic navigation to facilitate implantation of left ventricular leads - a revolutionary step into a future with less radiation
    Doering, M.
    Sommer, P.
    Rolf, S.
    Lucas, J.
    Piorkowski, C.
    Hindricks, G.
    Richter, S.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 87 - 87
  • [2] Usefulness of a Pacing Guidewire to Facilitate Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy
    De Cock, Carel C.
    Res, Jan C. J.
    Hendriks, Matthijs L.
    Allaart, Cornelis P.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (04): : 446 - 449
  • [3] Surgical implantation of left ventricular epicardial leads for cardiac resynchronization
    García-Bengochea, JB
    Fernández, AL
    Amaro, A
    Alvarez, J
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) : 184 - 185
  • [4] Robotic Assisted Implantation of Left Ventricular Epicardial Pacing Leads for Cardiac Resynchronization Therapy
    Liao, K.
    Li, X.
    Colvin-Adams, M.
    Boyle, A.
    Missov, E.
    Pritzker, M.
    Lu, F.
    Sakaguchi, S.
    Benditt, D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S97 - S97
  • [5] Surgical implantation of left ventricular epicardial leads for cardiac resynchronization - Reply
    Mair, H
    Daebritz, S
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) : 185 - 185
  • [6] Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy
    Jeong, Dong Seop
    Park, Pyo Won
    Lee, Young Tak
    Park, Seung-Jung
    Kim, June Soo
    On, Young Keun
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (12) : 1595 - 1597
  • [7] Left ventricular lead implantation guided bey sensor-based electromagnetic navigation in a patient with L-transposition of the great arteries
    Richter, Sergio
    Hindricks, Gerhard
    Daehnert, Ingo
    Doering, Michael
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (08) : 500 - 500
  • [8] Stimulus Intensity in Left Ventricular Leads and Response to Cardiac Resynchronization Therapy
    Bavikati, Venkata V.
    Langberg, Jonathan J.
    Williams, B. Robinson, III
    Kella, Danesh
    Lloyd, Michael S.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2012, 1 (05):
  • [9] Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads
    Yang, Mei
    Li, Xuping
    Liang, Jinjun
    Asirvatham, Samuel J.
    Espinosa, Raul
    Li, Yigang
    Friedman, Paul A.
    Cha, Yong-Mei
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (08): : 912 - 919
  • [10] Cardiac Resynchronization Therapy Device Implantation Using a New Sensor-Based Navigation System Results From the First Human Use Study
    Richter, Sergio
    Doering, Michael
    Gaspar, Thomas
    John, Silke
    Rolf, Sascha
    Sommer, Philipp
    Hindricks, Gerhard
    Piorkowski, Christopher
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (05): : 917 - 923