Evaluation of Bone Tunnel Placement for Suture Augmentation of an Injured Anterior Cruciate Ligament: Effects on Joint Stability in a Goat Model

被引:15
|
作者
Fisher, Matthew B. [1 ]
Jung, Ho-Joong [1 ,2 ]
McMahon, Patrick J. [1 ]
Woo, Savio L-Y [1 ]
机构
[1] Univ Pittsburgh, Musculoskeletal Res Ctr, Dept Bioengn, Swanson Sch Engn, Pittsburgh, PA 15219 USA
[2] Chung Ang Univ, Dept Orthopaed Surg, Coll Med, Seoul 156756, South Korea
基金
美国国家科学基金会;
关键词
anterior cruciate ligament (ACL); suture augmentation; biomechanics; robotic testing system; PLATELET-RICH PLASMA; REPLACEMENT GRAFT; PATELLAR TENDON; KNEE STABILITY; PRIMARY REPAIR; FOLLOW-UP; RECONSTRUCTION; ACL; RUPTURES; FLEXION;
D O I
10.1002/jor.21141
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Use of novel tissue engineering approaches to heal an injured anterior cruciate ligament (ACL) requires suture repair and/or augmentation to provide Joint stability We evaluated the effects of the location of suture augmentation at the femur and tibia in terms of.toint stability using a goat model Eight goat stifle joints were tested with augmentation sutures placed in two femoral tunnel locations (1) anterior to, or (2) through the ACL footprint, and two tibial tunnel locations (1) medial to, or (2) medial and lateral to the footprint Using a robotic/universal force-moment sensor testing system, the anterior tibial translation (ATT) and the corresponding in situ force carried by the sutures were obtained at 30 degrees, 60 degrees, and 90 degrees of flexion in response to external loads No significant differences were found between augmentation groups clue to tunnel location in terms of ATT or the in situ forces carried by the sutures at all flexion angles tested. Similar results were found under 5 N m of varus-valgus torque Under a 67 N anterior tibial load, the AN was restored to within :3mm of the intact joint following suture augmentation (p > 0 05) Suture augmentation, when placed close to the ACL insertion, could be helpful in providing initial joint stability to aid ACL healing in the goat model. (C) 2010 Orthopaedic Research Society Published by Wiley Periodicals, Inc J Orthop Res 28 1373-1379, 2010
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 50 条
  • [21] Suture Tape Augmentation of Anterior Cruciate Ligament Reconstruction Increases Biomechanical Stability: A Scoping Review of Biomechanical, Animal, and Clinical Studies
    Mackenzie, Christopher E. A.
    Huntington, Lachlan S.
    Tulloch, Scott
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2022, 38 (06): : 2073 - 2089
  • [22] Evaluation of the single-incision arthroscopic technique for anterior cruciate ligament replacement - A study of tibial tunnel placement, intraoperative graft tension, and stability
    Howell, SM
    Wallace, MP
    Hull, ML
    Deutsch, ML
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (03): : 284 - 293
  • [23] Suture Tape Augmentation Improves the Biomechanical Performance of Bone-Patellar Tendon-Bone Grafts Used for Anterior Cruciate Ligament Reconstruction
    Matava, Matthew J.
    Koscso, Jonathan
    Melara, Lucia
    Bogunovic, Ljiljana
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (11): : 3335 - 3343
  • [24] Knee stability and graft function after anterior cruciate ligament reconstruction - A comparison of a lateral and an anatomical femoral tunnel placement
    Yamamoto, Y
    Hsu, WH
    Woo, SLY
    Van Scyoc, AH
    Takakura, Y
    Debski, RE
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (08): : 1825 - 1832
  • [25] Functionalized biphasic silk scaffold for anterior cruciate ligament regeneration and bone tunnel healing in the porcine model
    Teh, T. K. H.
    Shi, P. J.
    Ren, X. F.
    Hui, J. H. P.
    Toh, S. L.
    Goh, J. C. H.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 401 - 401
  • [26] Influence of Bone Adaptation on Tendon-to-Bone Healing in Bone Tunnel after Anterior Cruciate Ligament Reconstruction in a Rabbit Model
    Wen, Chun-Yi
    Qin, Ling
    Lee, Kwong-Man
    Wong, Margaret Wan-Nar
    Chan, Kai-Ming
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (11) : 1447 - 1456
  • [27] Effects of the tibial tunnel position on knee joint stability and meniscal contact pressure after double-bundle anterior cruciate ligament reconstruction
    Sakamoto, Yukiko
    Tsukada, Harehiko
    Sasaki, Shizuka
    Kimura, Yuka
    Yamamoto, Yuji
    Tsuda, Eiichi
    Ishibashi, Yasuyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2020, 25 (06) : 1040 - 1046
  • [28] Firm anchoring between a calcium phosphate-hybridized tendon and bone for anterior cruciate ligament reconstruction in a goat model
    Mutsuzaki, Hirotaka
    Sakane, Masataka
    Hattori, Shinya
    Kobayashi, Hisatoshi
    Ochiai, Naoyuki
    BIOMEDICAL MATERIALS, 2009, 4 (04)
  • [29] Biomechanical evaluation of posterolateral corner reconstruction with suture augmentation in a posterolateral corner and posterior cruciate ligament deficient knee model
    Malige, Ajith
    Carbone, Andrew
    Huang, Dave T.
    Kanjiya, Shrey
    Rahman, Omar
    Banffy, Michael
    Metzger, Melodie F.
    CLINICAL BIOMECHANICS, 2025, 123
  • [30] Suture Augmentation Does Not Change Biomechanical Properties and Histological Remodeling of Tendon Graft in Anterior Cruciate Ligament Reconstruction: A Study in a Porcine Model
    Iwaasa, Tomoya
    Takahashi, Tsuneari
    Tensho, Keiji
    Koyama, Suguru
    Takeshita, Katsushi
    Takahashi, Jun
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (04): : 1014 - 1024