RETRACTED: Detection of 3D Arterial Centerline Extraction in Spiral CT Coronary Angiography (Retracted Article)

被引:0
|
作者
Cai, Wenjuan [1 ]
Wang, Yanzhe [1 ]
Gu, Liya [1 ]
Ji, Xuefeng [1 ]
Shen, Qiusheng [1 ]
Ren, Xiaogang [1 ,2 ]
机构
[1] Changshu Hosp Chinese Med, Changshu 215516, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Informat & Control Engn, Xuzhou 221116, Jiangsu, Peoples R China
关键词
CARDIAC COMPUTED-TOMOGRAPHY; HEMODYNAMIC SIGNIFICANCE; NONINVASIVE ASSESSMENT; PERFUSION; SEGMENTATION; VALIDATION; DISEASE; FUSION; MODEL;
D O I
10.1155/2021/2670793
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This paper presents an in-depth study and analysis of the 3D arterial centerline in spiral CT coronary angiography, and constructs its detection and extraction technique. The first time, the distance transform is used to complete the boundary search of the original figure; the second time, the distance transform is used to calculate the value of the distance transform of all voxels, and according to the value of the distance transform, unnecessary voxels are deleted, to complete the initial contraction of the vascular region and reduce the computational consumption in the next process; then, the nonwitnessed voxels are used to construct the maximum inner joint sphere model and find the skeletal voxels that can reflect the shape of the original figure. Finally, the skeletal lines were optimized on these initially extracted skeletal voxels using a dichotomous-like principle to obtain the final coronary artery centerline. Through the evaluation of the experimental results, the algorithm can extract the coronary centerline more accurately. In this paper, the segmentation method is evaluated on the test set data by two kinds of indexes: one is the index of segmentation result evaluation, including dice coefficient, accuracy, specificity, and sensitivity; the other is the index of clinical diagnosis result evaluation, which is to refine the segmentation result for vessel diameter detection. The results obtained in this paper were compared with the physicians' labeling results. In terms of network performance, the Dice coefficient obtained in this paper was 0.89, the accuracy was 98.36%, the sensitivity was 93.36%, and the specificity was 98.76%, which reflected certain advantages in comparison with the advanced methods proposed by previous authors. In terms of clinical evaluation indexes, by performing skeleton line extraction and diameter calculation on the results obtained by the segmentation method proposed in this paper, the absolute error obtained after comparing with the diameter of the labeled image was 0.382 and the relative error was 0.112, which indicates that the segmentation method in this paper can recover the vessel contour more accurately. Then, the results of coronary artery centerline extraction with and without fine branch elimination were evaluated, which proved that the coronary artery centerline has higher accuracy after fine branch elimination. The algorithm is also used to extract the centerline of the complete coronary artery tree, and the results prove that the algorithm has better results for the centerline extraction of the complete coronary vascular tree.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] RETRACTED: Learning spatiotemporal features with 3D DenseNet and attention for gesture recognition (Retracted Article)
    Liu, Honegzhe
    Deng, Zhifang
    Xu, Cheng
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2019,
  • [42] RETRACTED: 3D City Online Visualization and Cluster Architecture for Digital City (Retracted Article)
    Fu, Lin
    Ding, Yaqing
    JOURNAL OF SENSORS, 2021, 2021
  • [43] RETRACTED: Characteristics of hydraulic fracture surface based on 3D scanning technology (Retracted Article)
    Zhang, Fan
    Ma, Geng
    Tao, Yunqi
    Liu, Xiao
    Liu, Yixin
    Li, Rui
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (06):
  • [44] RETRACTED: Application of Computer 3D Modeling Technology in Graphic Image Design (Retracted Article)
    Liu, Jin
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2022, 2022
  • [45] Extraction Method of Coronary Artery Blood Vessel Centerline in CT Coronary Angiography
    Sheng, Xiaodong
    Fan, Tao
    Jin, Xiaoqi
    Jin, Jing
    Chen, Zhixian
    Zheng, Guanqun
    Lu, Min
    Zhu, Zongcheng
    IEEE ACCESS, 2019, 7 : 170690 - 170702
  • [46] RETRACTED: Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis (Retracted Article)
    Ma, Hong-Fei
    Chen, Liang
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [47] RETRACTED: Clinical Application of Digital 3D Reconstruction and 3D Printing Technology in Endometrial Cancer (EC) Surgery (Retracted Article)
    Luo, Fang
    Yang, Qin
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [48] RETRACTED: The Value of CT Angiography Based on Intelligent Segmentation Algorithm for Survival of Hemodialysis Patients (Retracted Article)
    Luo, Wei
    Zhang, Ruidong
    He, Da
    Sun, Zhenyi
    Zhou, Yunlong
    Cheng, Li
    Li, Hongbo
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [49] RETRACTED: Combined Application of CT Perfusion Imaging and CT Angiography in Imaging Diagnosis of Acute Cerebrovascular Diseases (Retracted Article)
    Li, Yanjiao
    Liu, Zhipeng
    Wu, Baojin
    Zhang, Jingrui
    Li, Chao
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [50] RETRACTED: Coronary Heart Disease Detection from Variation of Speech and Voice (Retracted Article)
    Mishra, Suman
    Balakrishnan, S.
    Babitha, M.
    PROCEEDINGS OF 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND APPLICATIONS, 2017, 467 : 583 - 594