Validity of ultrasound-guided aspiration needle biopsy in the diagnosis of micrometastases in sentinel lymph nodes in patients with cutaneous melanoma

被引:0
|
作者
Sijan, Goran [1 ,5 ]
Kozarski, Jefta [1 ,5 ]
Stepic, Nenad [1 ,5 ]
Milojevic, Sasa [2 ]
Stefanovic, Dara [2 ,5 ]
Tatomirovic, Zeljka [3 ,5 ]
Jaukovic, Ljiljana [4 ,5 ]
Vesanovic, Svetlana
Rajovic, Milica [1 ]
机构
[1] Mil Med Acad, Clin Plast Surg & Burns, Crnotravska 17, Belgrade 11000, Serbia
[2] Mil Med Acad, Inst Radiol, Belgrade, Serbia
[3] Mil Med Acad, Dept Cytol, Belgrade, Serbia
[4] Mil Med Acad, Inst Nucl Med, Belgrade, Serbia
[5] Univ Def, Mil Med Acad, Fac Med, Belgrade, Serbia
关键词
endoscopic ultrasound-guided fine needle aspiration; neoplasm; micrometastasis; sentinel lymph node biopsy; skin; melanoma; diagnosis; sensitivity and specificity; FOLLOW-UP; II MELANOMA; STAGE-I; METASTASES; LYMPHADENECTOMY; CYTOLOGY; TRIAL;
D O I
10.2298/VSP150227042S
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. Cutaneous melanoma is one of the most aggressive solid cancers, that develops local, regional and distant metastases. The presence of metastases in lymph nodes is in correlation with Breslow tumor thickness. According to various researches, in melanoma with more than 4 mm Breslow thickness, lymph node micrometastases can be found in 60-70% of cases. Sentinel lymph nodes biopsy is a diagnostic procedure for lymph node micrometastasis detection, which is necessary for disease staging. In recent studies, ultrasound-guided fine needle aspiration with cytology (US FNAC) of the sentinel lymph node was used as less invasive procedure, but is not accepted as the standard procedure. The goal of this work was to define sensitivity, specification and precision of the ultrasound-guided fine needle aspiration method in comparison with standard sentinel lymph node biopsy. Methods. After obtaining the Ethics Committee's permission, from 2012 to 2014 a total of 60 patients with cutaneous melanoma were enrolled, and divided into three groups: group I with thin melanoma, group II with intermediate thickness melanoma and group III with thick melanoma. The presence of micrometastases in sentinel regional lymph nodes was analyzed by US FNAC. The results obtained were compared to sentinel lymph nodes biopsy (SLNB) results. The golden standard for calculating the specific, sensitive and precise characteristics of the method of US FNAC of sentinel lymph nodes was histopathologic lymph node examination of sentinel lymph nodes acquired through biopsy. Results. Detection rate of US FNAC was 0% in the group I, 5% in the group II and 30% in the group III. SLNB detection rates were: 10% in the group I, 15% in the group II, and 45% in the group III. In melanoma thicker than 4 mm, 15% of the patients were false negative by US FNAC. The sensitivity of US FNAC for all the patients was 50%: in the group I, 0%; in the group II, 33.3%; and in the group III, 66.6%. The method specificity for all examined patients was 100% and accuracy 88%: group I, 90%; group II, 90%; group III, 85%. The FNAC and SLNB micrometastasis detection rate was significantly higher in melanoma with Breslow thickness > 4 mm (group 3) in comparison to thin and intermediate thickness tumors. Conclusion. The method of ultrasound-guided fine needle aspiration of sentinel lymph nodes, according to its sensitivity, has a place in the diagnostics of micrometastasis in regional lymph nodes only in thick melanoma, but not in thin and intermediary thickness melanoma. The results must be confirmed in a larger number of patients. If this observation could be confirmed, it would rationalize treatment of patients with thick melanoma, decrease the number of operations and shorten the time to make the diagnosis.
引用
收藏
页码:934 / 940
页数:7
相关论文
共 50 条
  • [41] Yield of endoscopic ultrasound-guided fine needle aspiration for subcentimetric lymph nodes: A comparison to larger nodes
    Choudhary, Narendra S.
    Bodh, Vijay
    Kumar, Naveen
    Puri, Rajesh
    Sarin, Haimanti
    Guleria, Mridula
    Piplani, Tarun
    Krishan, Sonal
    Rai, Rahul
    Sud, Randhir
    ENDOSCOPIC ULTRASOUND, 2017, 6 (03) : 168 - 173
  • [42] ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION BIOPSY OF THE LIVER
    LIN, BPC
    CHU, JMG
    ROSE, RA
    PATHOLOGY, 1987, 19 (02) : 173 - 177
  • [43] Ultrasound-guided fine needle aspiration biopsy in the diagnosis of chronic pulmonary infection
    Hsu, WH
    Chiang, CD
    Chen, CY
    Hsu, JY
    Chang, MC
    RESPIRATION, 1997, 64 (05) : 319 - 325
  • [44] ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION BIOPSY IN THE DIAGNOSIS OF HEPATIC HEMANGIOMA
    CATURELLI, E
    RAPACCINI, GL
    SABELLI, C
    DESIMONE, F
    FABIANO, A
    ROMAGNAMANOJA, E
    ANTI, M
    FEDELI, G
    LIVER, 1986, 6 (06): : 326 - 330
  • [45] The Effect of Radiotherapy on Ultrasound-Guided Fine Needle Aspiration Biopsy and the Ultrasound Characteristics of Neck Lymph Nodes in Oral Cancer Patients after Primary Treatment
    Lo, Wu-Chia
    Cheng, Po-Wen
    Wang, Chi-Te
    Shueng, Pei-Wei
    Hsieh, Chen-Hsi
    Chang, Yih-Leong
    Liao, Li-Jen
    PLOS ONE, 2016, 11 (03):
  • [46] Ultrasound-Guided Fine Needle Biopsy of Axillary Lymph Nodes: Efficacy in the Preoperative Diagnosis of Axillary Metastases in Breast Cancer Patients
    Staiger, Melinda
    Shah, Faisal
    Tobola, Maciej
    O'Connor, Kimberly
    Angermiller, Roberta
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (05): : 516 - 516
  • [47] Analysis of bleeding after ultrasound-guided needle biopsy of benign cervical lymph nodes
    Wenzhi Zhang
    Gaoyi Yang
    Jianping Xu
    Tu Ni
    Wei Tang
    Meiling Zhou
    BMC Surgery, 23
  • [48] The safety and efficiency of the ultrasound-guided large needle core biopsy of axilla lymph nodes
    Kim, Ki Hong
    Son, Eun Ju
    Kim, Eun-Kyung
    Ko, Kyung Hee
    Kang, Haeyoun
    Oh, Yj Kenn
    YONSEI MEDICAL JOURNAL, 2008, 49 (02) : 249 - 254
  • [49] Analysis of bleeding after ultrasound-guided needle biopsy of benign cervical lymph nodes
    Zhang, Wenzhi
    Yang, Gaoyi
    Xu, Jianping
    Ni, Tu
    Tang, Wei
    Zhou, Meiling
    BMC SURGERY, 2023, 23 (01)
  • [50] Formulating a Treatment Plan in Suspected Lymphoma: Ultrasound-Guided Core Needle Biopsy Versus Core Needle Biopsy and Fine-Needle Aspiration of Peripheral Lymph Nodes
    Drylewicz, Monica R.
    Watkins, Marcus P.
    Shetty, Anup S.
    Lin, Michael F.
    Salter, Amber
    Bartlett, Nancy L.
    Middleton, William D.
    Yano, Motoyo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (03) : 581 - 586