An Implantable Telemetry Platform System With ASIC for in Vivo Monitoring of Gastrointestinal Physiological Information

被引:7
|
作者
Lu, Li [1 ]
Yan, Guozheng [2 ]
Zhao, Kai [3 ]
Xu, Fei [3 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Med Precise Engn & Intelligent Microsyst, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Precis Instrument Sci & Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai 200240, Peoples R China
关键词
Application-specific integrated circuit (ASIC); wireless capsules; wireless sensors; three-stage clock management; power management; low power; WIRELESS MOTILITY CAPSULE; IC DESIGN; PH; IMPEDANCE;
D O I
10.1109/JSEN.2015.2392105
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a multiple channel, implantable biotelemetry platform, suitable for in vivo monitoring of gastrointestinal (GI) physiological information. This system consists of a wireless capsule, a portable data recorder, and a workstation; it can digitalize and transmit up to four analog signals coming from different sensors. Several design challenges involving system miniaturization, sensor-precision improvement, and power-dissipation reduction were resolved by employing optimized architecture, microsensors, and a low-power application-specific integrated circuit (ASIC) that applied a very large scale integration architecture of three-stage clock management, power management, and an 18-bits full-differential input sigma-delta analog-to-digital converter. pH, temperature, and pressure sensors were manufactured and assembled with the ASIC and the transmission circuit into an elliptical capsule. The capsule measured 25 mm in length and 11 mm in diameter to ensure that it would be easy for patients to swallow yet able to transmit GI physiological information wirelessly. Because of the implementation of the low-power ASIC, the capsule can work normally for 136 h with three 1.5 V 22-mA button batteries. The system performances were assessed through several vivid tests. In addition, results from 22 cases of application in humans are reported in this paper.
引用
收藏
页码:3524 / 3534
页数:11
相关论文
共 50 条
  • [21] TOWARDS AN IMPLANTABLE TELEMETRY SYSTEM FOR PHOTOPLETHYSMOGRAPHY BASED VITAL SIGNS MONITORING IN SMALL ANIMALS
    Wang, Qing
    Brun, Noe
    Huang, Qiuting
    Schonle, Philipp
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E12 - E12
  • [22] An implantable telemetry system for continuous chronic monitoring of kidney oxygenation in freely moving rats
    Russell, David Martin
    Garry, Emer
    Evans, Roger
    Eppel, Gabriela
    Abdelkader, Amany
    Taberner, Andrew
    Budgett, David
    Malpas, Simon
    [J]. FASEB JOURNAL, 2011, 25
  • [23] Live Demonstration: Wireless Telemetry System for Implantable Pressure-Volume Cardiac Monitoring
    Fricke, Kyle
    Sobot, Robert
    [J]. 2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 177 - 177
  • [24] Telemetry system for monitoring anterior cruciate ligament graft forces in vivo
    McKee, EL
    Hull, ML
    Howell, SM
    [J]. SMART MATERIALS TECHNOLOGIES: SMART STRUCTURES AND MATERIALS 1997, 1997, 3040 : 240 - 250
  • [25] Telemetry system for monitoring anterior cruciate ligament graft forces in vivo
    McKee, EL
    Lindsey, DP
    Hull, ML
    Howell, SM
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (03) : 330 - 336
  • [26] Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors
    Beach, RD
    Conlan, RW
    Godwin, MC
    Moussy, F
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) : 61 - 72
  • [27] Telemetry system for monitoring anterior cruciate ligament graft forcesin vivo
    E. L. McKee
    D. P. Lindsey
    M. L. Hull
    S. M. Howell
    [J]. Medical and Biological Engineering and Computing, 1998, 36 : 330 - 336
  • [28] Design of a telemetry system based on wireless power transmission for physiological parameter monitoring
    Jia, Zhiwei
    Yan, Guozheng
    Zhu, Bingquan
    [J]. AIP ADVANCES, 2015, 5 (04):
  • [29] A fully implantable telemetry system for the chronic monitoring of brain tissue oxygen in freely moving rats
    Russell, David M.
    Garry, Emer M.
    Taberner, Andrew J.
    Barrett, Carolyn J.
    Paton, Julian F. R.
    Budgett, David M.
    Malpas, Simon C.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2012, 204 (02) : 242 - 248
  • [30] Highly Integrated MEMS-ASIC Sensing System for Intracorporeal Physiological Condition Monitoring
    Xue, Ning
    Wang, Chao
    Liu, Cunxiu
    Sun, Jianhai
    [J]. SENSORS, 2018, 18 (01):