摘要
Electrical Impedance Tomography (EIT) calculates the internal conductivity distribution within a body using electrical contact measurements. Conventional EIT reconstruction methods solve a linear model by minimizing the least squares error, i.e., the Euclidian or L2-norm, with regularization. Compressed sensing provides unique advantages in Magnetic Resonance Imaging (MRI) [1] when the images are transformed to a sparse basis. EIT images are generally sparser than MRI images due to their lower spatial resolution. This leads us to investigate ability of compressed sensing algorithms currently applied to MRI in EIT without transformation to a new basis. In particular, we examine four new iterative algorithms for L1 and L0 minimization with applications to compressed sensing and compare these with current EIT inverse L1-norm regularization methods. The four compressed sensing methods are as follows: (1) an interior point method for solving L1-regularized least squares problems (L1-LS); (2) total variation using a Lagrangian multiplier method (TVAL3); (3) a two-step iterative shrinkage / thresholding method (TWIST) for solving the L0-regularized least squares problem; (4) The Least Absolute Shrinkage and Selection Operator (LASSO) with tracing the Pareto curve, which estimates the least squares parameters subject to a L1-norm constraint. In our investigation, using 1600 elements, we found all four CS algorithms provided an improvement over the best conventional EIT reconstruction method, Total Variation, in three important areas: robustness to noise, increased computational speed of at least 40x and a visually apparent improvement in spatial resolution. Out of the four CS algorithms we found TWIST was the fastest with at least a 100x speed increase.
引用
收藏
页码:3109 / 3112
页数:4
相关论文
共 50 条
  • [21] Comparison of Algorithms for Compressed Sensing of Magnetic Resonance Images
    Jelena, Badnjar
    2015 4TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING (MECO), 2015, : 303 - 306
  • [22] Precise damage shaping in self-sensing composites using electrical impedance tomography and genetic algorithms
    Hassan, Hashim
    Tallman, Tyler N.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2023, 22 (01): : 372 - 387
  • [23] Influence of Reconstruction Algorithms on Harmonic Analysis in Electrical Impedance Tomography
    Stein, Erik
    Chen, Rongqing
    Battistel, Alberto
    Lovas, Andras
    Benyo, Balazs
    Moeller, Knut
    IFAC PAPERSONLINE, 2023, 56 (02): : 5615 - 5619
  • [24] A Versatile Noise Performance Metric for Electrical Impedance Tomography Algorithms
    Braun, Fabian
    Proenca, Martin
    Sola, Josep
    Thiran, Jean-Philippe
    Adler, Andy
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (10) : 2321 - 2330
  • [25] Comparison of Compressed Sensing Based Algorithms for Sparse Signal Reconstruction
    Celik, Safa
    Basaran, Mehmet
    Erkucuk, Serhat
    Cirpan, Hakan Ali
    2016 24TH SIGNAL PROCESSING AND COMMUNICATION APPLICATION CONFERENCE (SIU), 2016, : 1441 - 1444
  • [26] COMPARISON OF RECONSTRUCTION ALGORITHMS IN COMPRESSED SENSING APPLIED TO BIOLOGICAL IMAGING
    Le Montagner, Yoann
    Angelini, Elsa
    Olivo-Marin, Jean-Christophe
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 105 - 108
  • [27] Electrical Impedance Tomography for Biological Cell Sensing with Microfluidic Device
    Yao J.
    Liu X.
    Xu Z.
    Zhao T.
    Chen B.
    Wu H.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2019, 55 (02): : 1 - 9
  • [28] Electrical impedance tomography for sensing with integrated microelectrodes on a CMOS microchip
    Chai, K. T. C.
    Davies, J. H.
    Cumming, D. R. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) : 97 - 101
  • [29] A comparison study of electrodes for neonate electrical impedance tomography
    Rahal, Mohamad
    Khor, Joo Moy
    Demosthenous, Andreas
    Tizzard, Andrew
    Bayford, Richard
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) : S73 - S84
  • [30] Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography
    Javaherian, Ashkan
    Soleimani, Manuchehr
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 1133 - 1149