Does Knee Flexion Influence the Relationship between the Femoral Tunnel and the Lateral Anatomic Structures During ACL Reconstruction?

被引:5
|
作者
Chung, Kwangho [1 ]
Kim, Sung-Jae [1 ]
Choi, Chong Hyuk [1 ]
Kim, Sung-Hwan [1 ]
Choi, Yunjong [2 ]
Jung, Min [1 ]
机构
[1] Yonsei Univ, Arthroscopy & Joint Res Inst, Dept Orthopaed Surg, Coll Med, CPO Box 8044,134 Shinchon Dong, Seoul 120752, South Korea
[2] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
ANTERIOR CRUCIATE LIGAMENT; SINGLE-BUNDLE; LENGTH; ANGLE; POSITION; LOCATION;
D O I
10.1097/CORR.0000000000000845
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In ACL reconstruction, the relationship of the femoral tunnel outlet to the anatomy of the lateral knee is clinically important, but whether that relationship is influenced by knee flexion using a transportal technique is unclear. Questions/purposes The purposes of this study were to (1) to describe the relationship between the outlet of the femoral tunnel and the lateral anatomic structures of the femur, including the lateral epicondyle, lateral collateral ligament, popliteus tendon, and lateral head of the gastrocnemius, as a function of knee flexion angle when the tunnel was created; and (2) to determine the knee flexion range of angles that best limits the risk of damage to these structures as the femoral tunnel is created during anatomic single-bundle ACL reconstruction using the transportal technique. Methods Between January 2017 and June 2018, 113 patients underwent ACL reconstruction, of which 62 (55%) who had a primary single-bundle ACL reconstruction with transportal technique using autogenous quadruple hamstring graft were included. Patients who were treated with grafts other than autogenous quadruple hamstring tendon, and had concomitant ligamentous injury, revisional ACL reconstruction, previous operative history of the affected knee, osseous deformity and osteoarthritis were excluded. Included patients were divided into three groups according to their knee flexion angles as the femoral tunnel was created. The femoral tunnel was created with rigid straight reamer with the knee flexed as much as possible in figure-of-four position and the flexion angle was measured with a sterile 12-inch goniometer intraoperatively for all patients. Fourteen patients (23%) had the femoral tunnel created with the knee in< 120 degrees offlexion, 23 (3 7%) had the tunnel created in 120 degrees to 129 degrees of flexion, and 25 (40%) had the tunnel created in >= 130 degrees of flexion. The femoral tunnel's outlet and the lateral anatomic structures of the femur, including the femoral origins of the lateral epicondyle, lateral collateral ligament, popliteus tendon, and lateral head of the gastrocnemius, were identified on a three-dimensional model that was reconstructed using CT images taken on postoperative day 1. The shortest distances from the femoral tunnel's outlet to these lateral anatomic structures were measured by two observers and interobserver reliability was high (intraclass correlation coefficient > 0.75). The distances were compared among the groups, and a correlation analysis of the measured distances regarding the knee flexion angle during creation of the femoral tunnel was performed. The safe distance was set as 12 mm between the centers of the femoral tunnel's outlet and the lateral structures considering the footprint of the lateral structures, diameter of the femoral tunnel, and femoral tunnel widening. Any anatomic structures that were closer to the femoral tunnel than the safe distance were noted, and the cutoff point of knee flexion for injury to the lateral anatomic structures was determined with a receiver operating characteristic curve. Results As knee flexion angle increased, the distance from the femoral tunnel to the lateral head of the gastrocnemius increased (r = 0.657, p < 0.001), and the distance to the lateral epicondyle decreased (r = -0.627, p < 0.001), as did the distance of the tunnel to the lateral collateral ligament (r = -0.443, p < 0.001) and the popliteus tendon (r = -0.653, p < 0.001). The cutoff point of the knee flexion angle associated with structural injury was 131 degrees (sensitivity, 70%; specificity, 73%) for the lateral collateral ligament and 121 degrees (sensitivity, 86%; specificity, 67%) for the lateral head of the gastrocnemius. Conclusions As knee flexion increased, the femoral tunnel's outlet tended to move more anteriorly and distally. Consequently, the safe distance to the lateral head of the gastrocnemius increased and the distances to the lateral epicondyle, lateral collateral ligament, and popliteus tendon decreased with increased knee flexion. To avoid possible damage to the lateral anatomic structures and obtain stable fixation in ACL reconstruction using the transportal technique, we recommend creating a femoral tunnel within 121 degrees and 131 degrees of knee flexion.
引用
收藏
页码:2228 / 2239
页数:12
相关论文
共 50 条
  • [41] Relationship Between Time to ACL Reconstruction and Presence of Adverse Changes in the Knee at the Time of Reconstruction
    Sommerfeldt, Mark
    Goodine, Tom
    Raheem, Abdul
    Whittaker, Jackie
    Otto, David
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (12):
  • [42] Does Anterior Laxity of the Uninjured Knee Influence Clinical Outcomes of ACL Reconstruction?
    Kim, Sung-Jae
    Lee, Su-Keon
    Kim, Sung-Hwan
    Kim, Seong-Hun
    Kim, Jong-Soon
    Jung, Min
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (07): : 543 - 548
  • [43] Single-bundle MCL reconstruction with anatomic single-bundle ACL reconstruction does not restore knee kinematics
    Zhu, Weimin
    Zhu, Junjun
    Marshall, Brandon
    Linde, Monica A.
    Smolinski, Patrick
    Fu, Freddie H.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (08) : 2687 - 2696
  • [44] Single-bundle MCL reconstruction with anatomic single-bundle ACL reconstruction does not restore knee kinematics
    Weimin Zhu
    Junjun Zhu
    Brandon Marshall
    Monica A. Linde
    Patrick Smolinski
    Freddie H. Fu
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2687 - 2696
  • [45] No Difference in Ligamentous Strain or Knee Kinematics Between Rectangular or Cylindrical Femoral Tunnels During Anatomic ACL Reconstruction With a Bone-Patellar Tendon-Bone Graft
    Burkhart, Timothy A.
    Hoshino, Takashi
    Batty, Lachlan M.
    Blokker, Alexandra
    Roessler, Philip P.
    Sidhu, Rajeshwar
    Drangova, Maria
    Holdsworth, David W.
    Petrov, Ivailo
    Degen, Ryan
    Getgood, Alan M.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (06)
  • [46] Poor knee function after ACL reconstruction is associated with attenuated landing force and knee flexion moment during running
    Perraton, Luke G.
    Hall, Michelle
    Clark, Ross A.
    Crossley, Kay M.
    Pua, Yong-Hao
    Whitehead, Tim S.
    Morris, Hayden G.
    Culvenor, Adam G.
    Bryant, Adam L.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (02) : 391 - 398
  • [47] Influence of femoral tunnel exit on the 3D graft bending angle in ACL reconstruction
    Hodel, Sandro
    Mania, Sylvano
    Vlachopoulos, Lazaros
    Furnstahl, Philipp
    Fucentese, Sandro F.
    [J]. SWISS MEDICAL WEEKLY, 2021, 151 : 27S - 27S
  • [48] Effect of femoral tunnel positions on graft stress in outside-in ACL reconstruction surgery during continuous knee motion: A simulation study
    Kang, Kyungmin
    Bae, Tae Soo
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (04):
  • [49] Poor knee function after ACL reconstruction is associated with attenuated landing force and knee flexion moment during running
    Luke G. Perraton
    Michelle Hall
    Ross A. Clark
    Kay M. Crossley
    Yong-Hao Pua
    Tim S. Whitehead
    Hayden G. Morris
    Adam G. Culvenor
    Adam L. Bryant
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 391 - 398
  • [50] Double-bundle ACL reconstruction: influence of femoral tunnel orientation in knee laxity analysed with a navigation system - an in-vitro biomechanical study
    Zaffagnini, Stefano
    Bruni, Danilo
    Martelli, Sandra
    Imakiire, Naoaki
    Marcacci, Maurilio
    Russo, Alessandro
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)