Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility

被引:26
|
作者
Fontana, M. [1 ]
Ley, J. -L. [1 ]
Dauvergne, D. [2 ]
Freud, N. [3 ]
Krimmer, J. [1 ]
Letang, J. M. [3 ]
Maxim, V. [3 ]
Richard, M. -H. [1 ]
Rinaldi, I. [1 ]
Testa, E. [1 ]
机构
[1] Univ Claude Bernard Lyon 1, CNRS IN2P3, Inst Phys Nucl Lyon, Univ Lyon, F-69622 Villeurbanne, France
[2] Univ Grenoble Alpes, CNRS, LPSC IN2P3, Grenoble INP, F-38000 Grenoble, France
[3] Univ Claude Bernard Lyon 1, CREATIS UMR 5220 U1206, Univ Lyon, CNRS,Inserm,Ctr Leon Berard,INSA Lyon,UJM St Etie, F-69373 Lyon, France
关键词
Clinical applicability; Compton camera; ion therapy; prompt gamma (PG); IMAGE-RECONSTRUCTION; PROTON THERAPY; SLIT CAMERA; OPTIMIZATION; IRRADIATION; RESOLUTION; EMISSION; DESIGN;
D O I
10.1109/TRPMS.2019.2933985
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As more and more particle therapy centers are being built world-wide, there is increasing need in treatment monitoring methods, ideally in real time. This article investigates the clinical applicability of a Compton camera design by means of Monte Carlo simulations. The Compton camera performance has been studied with the simulation of point-like source and beam irradiation of a polymethyl methacrylate (PMMA) phantom. The system absolute photon detection efficiency, measured via source irradiation, varies in the range [1, 4] x 10(-4) with energy variations in the prompt gamma (PG) energy range and source position shifts with respect to the center of the camera. With proton and carbon beams impinging on a PMMA cylindrical phantom, the number of detected PG coincidences related to various beam time structure has been studied. Finally, the accuracy of the camera in identifying the dose profile fall-off position has been estimated and two different event reconstruction methods have been compared for this purpose; one based on analytical calculation with a line-cone technique, the second relying on an iterative maximum likelihood expectation maximization algorithm. Both methods showed the possibility to reconstruct the beam depth-dose profile and to retrieve the dose fall-off with millimeter precision on a spot basis.
引用
收藏
页码:218 / 232
页数:15
相关论文
共 50 条
  • [41] Experience and new prospects of PET imaging for ion beam therapy monitoring
    Parodi, Katia
    Yamaya, Taiga
    Moskal, Pawel
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (01): : 22 - 34
  • [42] Feasibility Study on the Use of a Superconducting Synchrocyclotron and Electron Beam Ion Source for Heavy-Ion Therapy
    Jongwon Kim
    [J]. Journal of the Korean Physical Society, 2018, 73 : 1088 - 1092
  • [43] Feasibility Study on the Use of a Superconducting Synchrocyclotron and Electron Beam Ion Source for Heavy-Ion Therapy
    Kim, Jongwon
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (08) : 1088 - 1092
  • [44] First clinical application of carbon ion beam therapy at GSI
    Debus, J
    Kraft, G
    Hartmann, G
    Wenz, F
    Wannenmacher, M
    [J]. PROGRESS IN RADIO-ONCOLOGY VI, 1998, : 685 - 691
  • [45] Interaction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study
    Henriquet, P.
    Testa, E.
    Chevallier, M.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Ray, C.
    Richard, M-H
    Sauli, F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4655 - 4669
  • [46] TREATMENT PLANNING FOR SCANNED ION BEAM THERAPY IN CLINICAL ROUTINE
    Ellerbrock, M.
    Ackermann, B.
    Brons, S.
    Heeg, P.
    Henkner, K.
    Ecker, S.
    Nairz, O.
    Winter, M.
    Mairani, A.
    Parodi, K.
    Jaekel, O.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S542 - S543
  • [47] The RBE in ion beam radiotherapy: In vivo studies and clinical application
    Karger, Christian P.
    Glowa, Christin
    Peschke, Peter
    Kraft-Weyrather, Wilma
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 105 - 121
  • [48] Hadron minibeam radiation therapy: feasibility study at the Heidelberg Ion-Beam Therapy Center (HIT)
    Martinez-Rovira, I.
    Brons, S.
    Prezado, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S70 - S71
  • [49] Analytical and simulation studies for diode and triode ion beam extraction systems
    M. M. Abdelrahman
    N. I. Basal
    S. G. Zakhary
    [J]. 中国物理C, 2012, (04) - 349
  • [50] Analytical and simulation studies for diode and triode ion beam extraction systems
    M. M. Abdelrahman
    N. I. Basal
    S. G. Zakhary
    [J]. Chinese Physics C, 2012, 36 (04) : 344 - 349