Computer-aided detection systems for breast masses: Comparison of performances on full-field digital mammograms and digitized screen-film mammograms

被引:21
|
作者
Wei, Jun [1 ]
Hadjiiski, Lubomir M. [1 ]
Sahiner, Berkman [1 ]
Chan, Heang-Ping [1 ]
Ge, Jun [1 ]
Roubidoux, Marilyn A. [1 ]
Helvie, Mark A. [1 ]
Zhou, Chuan [1 ]
Wu, Yi-Ta [1 ]
Paramagul, Chintana [1 ]
Zhang, Yiheng [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computer-aided detection; mass detection; full-field digital mammogram (FFDM); screen-film mammogram (SFM); free-response receiver operating characteristic (FROC);
D O I
10.1016/j.acra.2007.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To compare the performance of computer aided detection (CAD) systems on pairs of full-field digital mammogram (FFDM) and screen-film mammogram (SFM) obtained from the same patients. Materials and Methods. Our CAD systems on both modalities have similar architectures that consist of five steps. For FFDMs, the input raw image is first log-transformed and enhanced by a multiresolution preprocessing scheme. For digitized SFMs, the input image is smoothed and subsampled to a pixel size of 100 mu m x 100 mu m. For both CAD systems, the mammogram after preprocessing undergoes a gradient field analysis followed by clustering-based region growing to identify suspicious breast structures. Each of these structures is refined in a local segmentation process. Morphologic and texture features are then extracted from each detected structure, and trained rule-based and linear discriminant analysis classifiers are used to differentiate masses from normal tissues. Two datasets, one with masses and the other without masses, were collected. The mass dataset contained 131 cases with 131 biopsy proven masses, of which 27 were malignant and 104 benign. The true locations of the masses were identified by an experienced Mammography Quality Standards Act (MQSA) radiologist. The no-mass data set contained 98 cases. The time interval between the FFDM and the corresponding SFM was 0 to 118 days. Results. Our CAD system achieved case-based sensitivities of 70%, 80%, and 90% at 0.9, 1.5, and 2.6 false positive (FP) marks/image, respectively, on FFDMs, and the same sensitivities at 1.0, 1.4, and 2.6 Fl? marks/image, respectively, on SFMs. Conclusions. The difference in the performances of our FFDM and SFM CAD systems did not achieve statistical significance.
引用
收藏
页码:659 / 669
页数:11
相关论文
共 50 条
  • [1] Computer-aided detection system for clustered microcalcifications: comparison of performance on full-field digital mammograms and digitized screen-film mammograms
    Ge, Jun
    Hadjiiski, Lubomir M.
    Sahiner, Berkman
    Wei, Jun
    Helvie, Mark A.
    Zhou, Chuan
    Chan, Heang-Ping
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (04): : 981 - 1000
  • [2] Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training
    Kallenberg, Michiel
    Karssemeijer, Nico
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23): : 6879 - 6891
  • [3] Effect of computer-aided detection on independent double reading of paired screen-film and full-field digital screening mammograms
    Skaane, Per
    Kshirsagar, Ashwini
    Stapleton, Sandra
    Young, Kari
    Castellino, Ronald A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 377 - 384
  • [4] Computer-aided detection of breast masses depicted on full-field digital mammograms: a performance assessment
    Zheng, B.
    Sumkin, J. H.
    Zuley, M. L.
    Lederman, D.
    Wang, X.
    Gur, D.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014): : E153 - E161
  • [5] Comparison of computerized image analyses for digitized screen-film mammograms and full-field digital mammography images
    Li, Hui
    Giger, Maryellen L.
    Yuan, Yading
    Lan, Li
    Suzuki, Kenji
    Jamieson, Andrew
    Yarusso, Laura
    Nishikawa, Robert M.
    Sennett, Charlene
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 569 - 575
  • [6] Computer-aided detection system applied to full-field digital mammograms
    Vega Bolivar, Alfonso
    Sanchez Gomez, Sonia
    Merino, Paula
    Alonso-Bartolome, Pilar
    Ortega Garcia, Estrella
    Munoz Cacho, Pedro
    Hoffmeister, Jeffrey W.
    [J]. ACTA RADIOLOGICA, 2010, 51 (10) : 1086 - 1092
  • [7] Computer-Aided Detection with Full-Field Digital Mammography and Screen-Film Mammography
    Melton, A. R.
    Worrell, S. W.
    Knapp, J.
    Hoffmeister, J. W.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [8] Computer-aided detection (CAD) of breast cancer on full field digital and screening film mammograms
    Sun, XJ
    Qian, W
    Song, XS
    Qian, YY
    Song, DS
    Clark, RA
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 930 - 939
  • [9] Computer aided detection of breast masses from digitized mammograms
    Zhang, H
    Foo, SW
    [J]. CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1393 - 1393
  • [10] Computer aided detection of breast masses from digitized mammograms
    Zhang, H
    Foo, SW
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2006, E89D (06) : 1955 - 1961