High-resolution 3T MR Neurography of Suprascapular Neuropathy

被引:19
|
作者
Chalian, Majid [1 ]
Faridian-Aragh, Neda [1 ]
Soldatos, Theodoros [1 ]
Batra, Kiran [1 ]
Belzberg, Allan J. [2 ]
Williams, Eric H. [3 ]
Carrino, John A. [1 ]
Chhabra, Avneesh [1 ]
机构
[1] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Neurosurg, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ Hosp, Dept Plast Surg, Baltimore, MD 21287 USA
关键词
Suprascapular nerve; neuropathy; magnetic resonance neurography; magnetic resonance imaging; brachial plexus; brachial plexopathy; MAGNETIC-RESONANCE NEUROGRAPHY; NERVE ENTRAPMENT; BRACHIAL-PLEXUS;
D O I
10.1016/j.acra.2011.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to illustrate the imaging findings on high-resolution 3T magnetic resonance neurography (MRN) in patients with suprascapular nerve (SSN) neuropathy. Materials and Methods: From 3T MRN examinations performed for brachial plexus evaluation in 51 patients over a 3-year period, 15 patients with final diagnosis of suprascapular neuropathy were recruited. The diagnosis was confirmed by electrodiagnostic studies (EDS), clinical, and/or surgical follow-up examinations. Studies performed for the evaluation of tumor, neurofibromatosis, or known diffuse polyneuropathy were excluded. Results: Two cases were excluded due to suboptimal imaging related to motion degradation and poor signal-to-noise ratio. MRN depicted asymmetric enlargement and/or abnormal T2 hyperintensity of 05 nerve root (10/13 cases), C6 nerve root (10/13 cases), both C5 and C6 nerve roots (7/13 cases), upper trunk (11/13 cases) and SSN (11/13 cases), and other brachial plexus segments involvement (4/13 cases). MR findings of denervation changes in the ipsilateral supraspinatus and infraspinatus muscles were detected in 12/13 cases. In all seven cases where contrast-enhanced images were available, MRN demonstrated enhancement of the denervated muscles but did not provide any additional information regarding the nerve abnormality. None of the MRN studies revealed a mass lesion along the course of the SSN. Conclusion: 3T MRN is a valuable diagnostic tool in clinically suspected cases of suprascapular neuropathy, because it can directly demonstrate the nerve abnormality, as well as secondary muscle denervation changes. The reader should be aware that brachial plexopathy may coexist in patients with clinical diagnosis of SSN neuropathy.
引用
收藏
页码:1049 / 1059
页数:11
相关论文
共 50 条
  • [31] High-Resolution MR Neurography: Evaluation Before Repeat Tarsal Tunnel Surgery
    Chhabra, Avneesh
    Subhawong, Ty K.
    Williams, Eric H.
    Wang, Kenneth C.
    Hashemi, Shar
    Thawait, Shrey K.
    Carrino, John A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) : 175 - 183
  • [32] Identification of long thoracic nerve on high-resolution 3T MRI
    Lee, Susan C.
    Geannette, Christian S.
    Sneag, Darryl B.
    CLINICAL IMAGING, 2020, 64 : 97 - 102
  • [33] Peripheral nerves and plexus: imaging by MR-neurography and high-resolution ultrasound
    Pham, Mirko
    Baeumer, Tobias
    Bendszus, Martin
    CURRENT OPINION IN NEUROLOGY, 2014, 27 (04) : 370 - 379
  • [34] Do TIAs require investigation by thin-slice high-resolution diffusion MRI with a 3T MR unit?
    Lehmann, P.
    Brasseur, A.
    Saliou, G.
    Canaple, S.
    Deramond, H.
    EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 (07) : E62 - E63
  • [35] High-resolution microscopic diffusion anisotropy imaging in the human hippocampus at 3T
    Yoo, Jiyoon
    Kerkela, Leevi
    Hales, Patrick W.
    Seunarine, Kiran K.
    Clark, Christopher A.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1903 - 1913
  • [36] Spectrum of Suprascapular Nerve Lesions: Normal and Abnormal Neuromuscular Imaging Appearances on 3-T MR Neurography
    Ahlawat, Shivani
    Wadhwa, Vibhor
    Belzberg, Allan J.
    Batra, Kiran
    Chhabra, Avneesh
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 589 - 601
  • [37] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Di Qian
    Paul A Bottomley
    Journal of Cardiovascular Magnetic Resonance, 14
  • [38] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Qian, Di
    Bottomley, Paul A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [39] High-resolution imaging at 3T and 7T with multiring local volume coils
    Fakhereh Mirrashed
    Jonathan C. Sharp
    Iva Cheung
    Boguslaw Tomanek
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 167 - 173
  • [40] High-resolution 3 T MR microscopy imaging of arterial walls
    Sailer, Johannes
    Rand, Thomas
    Berg, Andreas
    Sulzbacher, Irene
    Peloschek, P.
    Hoelzenbein, Thomas
    Lammer, Johannes
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (05) : 771 - 777