Simultaneous measurement of red blood cell aggregation and viscosity: Light transmission slit rheometer

被引:0
|
作者
Shin, S
Park, MS
Ku, Y
Jang, JH
Suh, JS
机构
[1] Kyungpook Natl Univ, Sch Mech Engn, Taegu 702701, South Korea
[2] Kyungpook Natl Univ Hosp, Dept Lab Med, Deagu 700721, South Korea
关键词
aggregation; red blood cell; viscosity; light; transmission; critical shear rate;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Aggregation of red blood cells (RBCs) is a major determinant of blood viscosity. There have not been available techniques for measuring RBC aggregation and viscosity, simultaneously. A laser transmission technique has been combined with a slit rheometry, which shows significant advances in rheometer design, operation and data analysis. A laser beam traverses a blood suspension flowing through a slit and is scattered by RBCs in the volume. The transmitted light is captured by a photodiode, linked to a computer, while the differential pressure variation is measured by a pressure transducer. Both measurements of the laser-transmitted intensity and pressure with respect to time enable to determine the aggregation index and the viscosity. The advantages of this design are in its simplicity, i.e., ease of operation and no moving parts, low cost and a short operating time. In addition, the slit-flow aggregometer can be easily used in a clinical setting owing to the incorporation of a disposable element that holds the blood sample.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 50 条
  • [31] PHYSIOLOGICAL MODIFICATIONS OF BLOOD-VISCOSITY AND RED-BLOOD-CELL AGGREGATION DURING LABOR AND DELIVERY
    BRUN, JF
    BOULOT, P
    MICALLEF, JP
    VIALA, JL
    ORSETTI, A
    CLINICAL HEMORHEOLOGY, 1995, 15 (01): : 13 - 24
  • [32] Increased red blood cell aggregation and blood viscosity in cardiac syndrome X as a cause of microcirculatory dysfunction
    Lee, Byoung Kwon
    Alexy, Tamas
    Wenby, Rosalinda
    Durairaj, Azhil
    Mehra, Anilkumar
    Meiselman, Herbert J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 233A - 233A
  • [33] Effects of nattokinase, a pro-fibrinolytic enzyme, on red blood cell aggregation and whole blood viscosity
    Pais, Eszter
    Alexy, Tamas
    Holsworth, Ralph E., Jr.
    Meiselman, Herbert J.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2006, 35 (1-2) : 139 - 142
  • [34] RED-CELL AGGREGATION IN BLOOD-FLOW .2. EFFECT ON APPARENT VISCOSITY OF BLOOD
    SCHMIDSCHONBEIN, H
    GALLASCH, G
    GOSEN, JV
    VOLGER, E
    KLOSE, HJ
    KLINISCHE WOCHENSCHRIFT, 1976, 54 (04): : 159 - 167
  • [35] INTERNAL VISCOSITY OF RED CELL AND A BLOOD VISCOSITY EQUATION
    DINTENFASS, L
    NATURE, 1968, 219 (5157) : 956 - +
  • [36] Simulation of simultaneous measurement for red blood cell thickness and refractive index
    Jin, Weifeng
    Wang, Yawei
    Ren, Naifei
    Bu, Min
    Shang, Xuefu
    Xu, Yuanyuan
    Chen, Yujiao
    OPTICS AND LASERS IN ENGINEERING, 2012, 50 (02) : 154 - 158
  • [37] MEASUREMENT OF RED CELL AGGREGATION AND DISPERSION
    ENGESET, J
    DHALL, DP
    MATHESON, NA
    BIBLIOTHECA ANATOMICA, 1969, (10): : 80 - &
  • [38] Development of an online rheometer for simultaneous measurement of shear and extensional viscosity during the polymer extrusion process
    Luger, Hans-Juergen
    Miethlinger, Juergen
    POLYMER TESTING, 2019, 77
  • [39] A COUETTE RHEOMETER DESIGN FOR MINIMIZING SEDIMENTATION AND RED-CELL-AGGREGATION ARTIFACTS IN LOW-SHEAR BLOOD RHEOMETRY
    ROSENBLATT, JS
    SOANE, DS
    WILLIAMS, MC
    BIORHEOLOGY, 1987, 24 (06) : 811 - 816
  • [40] Light scattering method to measure red blood cell aggregation during incubation
    Grzegorzewski, B.
    Szolna-Chodor, A.
    Baryla, J.
    Drezek, D.
    THIRTEENTH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2017, 10612