An Adaptive Under Frequency Load Shedding Scheme for a Small Island Power System

被引:0
|
作者
Powell, C. [1 ]
Bahadoorsingh, S. [2 ]
Singh, A. [2 ]
Sharma, C. [2 ]
机构
[1] Trinidad & Tobago Elect Commiss, Protect & SCADA Dept, Port Of Spain, Trinidad Tobago
[2] Univ West Indies, Dept Elect & Comp Engn, St Augustine, Trinidad Tobago
关键词
Under-frequency Load Shedding (UFLS); Adaptive Control; Wide Area Monitoring and Control; System Frequency Response (RFS);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An adaptive under-frequency load shedding scheme for an island power system is presented. This scheme monitors the frequency at the each generation bus in the system and employs a modified swing equation to estimate the power imbalance in the system following a disturbance and shed load accordingly at the feeder level. A reduced order system frequency response model was also developed and used to study the transient performance of the proposed scheme. The results presented illustrate this adaptive scheme is predictable and effective at curtailing the frequency deviation following the loss of the largest infeed on the Trinidad & Tobago power system. In all the cases studied, the power imbalance was found to be within 2% of the actual and the frequency recovered to within 99.5% of nominal in less than 8 seconds.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Monotonic control characteristics of under-frequency load shedding in power system
    Liu Y.
    Chen M.
    Li J.
    Zhang Q.
    Gan D.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (07): : 182 - 189
  • [32] Dynamic Under Frequency Load Shedding in Power Systems
    Ben Kilani, Khadija
    Elleuch, Mohamed
    Hamida, Adnene Haj
    2017 14TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2017, : 377 - 382
  • [33] An approach to design power system under frequency load shedding scheme taking coherent area and global optimization into account
    Xie, Da
    He, Heng-Jing
    Chang, Xi-Qiang
    Yao, Xiu-Ping
    Dianwang Jishu/Power System Technology, 2010, 34 (06): : 106 - 112
  • [34] Towards an enhanced power system sustainability: An MILP under - frequency load shedding scheme considering demand response resources
    Rafinia, Ali
    Moshtagh, Jamal
    Rezaei, Navid
    SUSTAINABLE CITIES AND SOCIETY, 2020, 59 (59)
  • [35] An improved adaptive wide-area load shedding scheme for voltage and frequency stability of power systems
    Mehrabi, Kazem
    Golshannavaz, Sajjad
    Afsharnia, Saeed
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2019, 10 (03): : 821 - 842
  • [36] An improved adaptive wide-area load shedding scheme for voltage and frequency stability of power systems
    Kazem Mehrabi
    Sajjad Golshannavaz
    Saeed Afsharnia
    Energy Systems, 2019, 10 : 821 - 842
  • [37] New centralized adaptive under frequency load shedding algorithms
    Pasand, M. Sanaye
    Seyedi, H.
    2007 LARGE ENGINEERING SYSTEMS CONFERENCE ON POWER ENGINEERING, 2007, : 43 - 47
  • [38] Enhancing power system stability with adaptive under frequency load shedding using synchrophasor measurements and empirical mode decomposition
    Dedovic, Maja Muftic
    Avdakovic, Samir
    Music, Mustafa
    Kuzle, Igor
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 160
  • [39] An Under-frequency Load Shedding Scheme with Continuous Load Control Proportional to Frequency Deviation
    Li, Changgang
    Sun, Yanli
    Yu, Yawei
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [40] Secure Under Frequency Load Shedding Scheme with Consideration of Rate of Change of Frequency
    Elyasichamazkoti, Farhad
    Teimourzadeh, Saeed
    2021 13TH ANNUAL IEEE GREEN TECHNOLOGIES CONFERENCE GREENTECH 2021, 2021, : 552 - 557