Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study

被引:158
|
作者
Cai, Jing [1 ]
Chang, Zheng [1 ]
Wang, Zhiheng [1 ]
Segars, William Paul [2 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
4D-MRI; 4D-CT; tumor motion; respiratory motion; cine-MRI; COMPUTED-TOMOGRAPHY; MOTION; RADIOTHERAPY; XCAT; MOBILITY; PHANTOM;
D O I
10.1118/1.3658737
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Four-dimensional computed tomography (4D-CT) has been widely used in radiation therapy to assess patient-specific breathing motion for determining individual safety margins. However, it has two major drawbacks: low soft-tissue contrast and an excessive imaging dose to the patient. This research aimed to develop a clinically feasible four-dimensional magnetic resonance imaging (4D-MRI) technique to overcome these limitations. Methods: The proposed 4D-MRI technique was achieved by continuously acquiring axial images throughout the breathing cycle using fast 2D cine-MR imaging, and then retrospectively sorting the images by respiratory phase. The key component of the technique was the use of body area (BA) of the axial MR images as an internal respiratory surrogate to extract the breathing signal. The validation of the BA surrogate was performed using 4D-CT images of 12 cancer patients by comparing the respiratory phases determined using the BA method to those determined clinically using the Real-time position management (RPM) system. The feasibility of the 4D-MRI technique was tested on a dynamic motion phantom, the 4D extended Cardiac Torso (XCAT) digital phantom, and two healthy human subjects. Results: Respiratory phases determined from the BA matched closely to those determined from the RPM: mean (+/- SD) difference in phase: -3.9% (+/- 6.4%); mean (+/- SD) absolute difference in phase: 10.40% (+/- 3.3%); mean (+/- SD) correlation coefficient: 0.93 (+/- 0.04). In the motion phantom study, 4D-MRI clearly showed the sinusoidal motion of the phantom; image artifacts observed were minimal to none. Motion trajectories measured from 4D-MRI and 2D cine-MRI (used as a reference) matched excellently: the mean (6SD) absolute difference in motion amplitude: -0.3 (+/- 0.5) mm. In the 4D-XCAT phantom study, the simulated "4D-MRI" images showed good consistency with the original 4D-XCAT phantom images. The motion trajectory of the hypothesized "tumor" matched excellently between the two, with a mean (+/- SD) absolute difference in motion amplitude of 0.5 (+/- 0.4) mm. 4D-MRI was able to reveal the respiratory motion of internal organs in both human subjects; superior-inferior (SI) maximum motion of the left kidney of Subject #1 and the diaphragm of Subject #2 measured from 4D-MRI was 0.88 and 1.32 cm, respectively. Conclusions: Preliminary results of our study demonstrated the feasibility of a novel retrospective 4D-MRI technique that uses body area as a respiratory surrogate. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3658737]
引用
收藏
页码:6384 / 6394
页数:11
相关论文
共 50 条
  • [21] Image-Based Correction of External Respiratory Surrogate Signal for Accurate T2-Weighted 4D MRI
    Uh, J.
    Kadbi, M.
    Hua, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E647 - E647
  • [22] Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
    Rietzel, E
    Chen, GTY
    Choi, NC
    Willet, CG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1535 - 1550
  • [23] Retrospective 4D-MRI with a Novel Image-Based Surrogate: A Sagittal-Coronal-Diaphragm Point of Intersection (SCD-PoI) Motion Tracking Method
    Liu, Y.
    Yin, F.
    Czito, B.
    Bashir, M.
    Palta, M.
    Cai, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3736 - 3736
  • [24] Four-dimensional (4-D) treatment planning integrating respiratory phases and three-dimensional (3-D) movements of lung and liver tumors using high-speed computed tomography (CT) and magnetic resonance imaging (MRI)
    Shirato, H
    Shimizu, S
    Bo, X
    Kagei, K
    Hashimoto, S
    Nishioka, T
    Akita, H
    Miyasaka, K
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 265 - 270
  • [25] Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Sung Eun Park
    Ho Cheol Kim
    Anne Menini
    European Radiology, 2020, 30 : 5130 - 5138
  • [26] A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging
    Clough, Rachel E.
    Waltham, Matthew
    Giese, Daniel
    Taylor, Peter R.
    Schaeffter, Tobias
    JOURNAL OF VASCULAR SURGERY, 2012, 55 (04) : 914 - 923
  • [27] Hemodynamics in a three-dimensional printed aortic model: a comparison of four-dimensional phase-contrast magnetic resonance and image-based computational fluid dynamics
    Jieun Park
    Junghun Kim
    Sinjae Hyun
    Jongmin Lee
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 719 - 732
  • [28] Hemodynamics in a three-dimensional printed aortic model: a comparison of four-dimensional phase-contrast magnetic resonance and image-based computational fluid dynamics
    Park, Jieun
    Kim, Junghun
    Hyun, Sinjae
    Lee, Jongmin
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (05) : 719 - 732
  • [29] Comparison of Four-Dimensional Flow Magnetic Resonance Imaging and Particle Image Velocimetry to Quantify Velocity and Turbulence Parameters
    Kim, Doohyeon
    Kang, Jihun
    Adeeb, Ehsan
    Lee, Gyu-Han
    Yang, Dong Hyun
    Ha, Hojin
    FLUIDS, 2021, 6 (08)
  • [30] Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Park, Sung Eun
    Kim, Ho Cheol
    Menini, Anne
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 5130 - 5138