Determination of 5-Hydroxyindole-3-Acetic Acid in Wastewater by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometric Detection

被引:3
|
作者
Jang, Mongjoo [1 ]
Chernyshov, V. D. [1 ]
Pirogov, A., V [1 ]
Tataurova, O. G. [2 ]
Rozhanets, V. V. [3 ]
Shpigun, O. A. [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Div Analyt Chem, Moscow, Russia
[2] Russian Acad Sci, Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
[3] Minist Hlth Russian Federat, Serbsky Fed Med Res Ctr Psychiat & Narcolgy, Moscow, Russia
关键词
5-hydroxyindole-3-acetic acid; biomarkers; high performance liquid chromatography; mass spectrometry; wastewater; liquid-liquid extraction;
D O I
10.1134/S002016851914005X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Analysis of biomarkers in wastewater is increasingly seen as an important tool for valuation of health, nutrition and use of various substances by humans. Some biomarkers are used for population estimates, since the actual values of population size in cities can differ significantly from official counts, which inevitably leads to errors in assessing the impact of various factors to people calculated per capita. 5-hydroxyindole-3-acetic acid (5-HIAA) is the main metabolite of serotonin, which is excreted by urine and can be used as a biomarker for population estimates. The determination of this metabolite is more preferred than the detection of serotonin itself in terms of correctness of the results. A technique of extraction and subsequent quantitative determination of 5-HIAA in wastewater by high-performance liquid chromatography in combination with tandem mass spectrometric detection was developed. Poroshell Hilic column was used as a stationary phase which has an alternative selectivity compared to traditional C18 columns. Developed procedure is characterized by low detection limits (0.2 mu g/L) and good selectivity. The conditions for liquid-liquid extraction of 5-HIAA from wastewater were selected. This technique provides reliable estimation of the concentration of 5-HIAA in wastewater.
引用
收藏
页码:1352 / 1358
页数:7
相关论文
共 50 条
  • [31] Simultaneous determination of serotonin and 5-hydroxyindole-3-acetic acid in human urine by automated precolumn derivatization and semi-microbore column liquid chromatography with fluorescence detection
    Yoshitake, T
    Iizuka, R
    Fujino, K
    Inoue, O
    Yamagata, K
    Nohta, H
    Yamaguchi, M
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1687 - 1690
  • [32] QUANTITATIVE METHOD FOR DETERMINATION OF SEROTONIN AND 5-HYDROXYINDOLE-3-ACETIC ACID IN CEREBROSPINAL-FLUID
    KEMMERER, V
    KOCH, TR
    LICHTENFELD, KM
    CLINICAL CHEMISTRY, 1977, 23 (06) : 1122 - 1122
  • [33] Simultaneous Determination of Serotonin and 5-Hydroxyindole-3-acetic Acid in Human Urine by Automated Precolumn Derivatization and Semi-microbore Column Liquid Chromatography with Fluorescence Detection
    Takashi Yoshitake
    Ryuji Iizuka
    Kaoru Fujino
    Osamu Inoue
    Kenji Yamagata
    Hitoshi Nohta
    Masatoshi Yamaguchi
    Analytical Sciences, 2004, 20 : 1687 - 1690
  • [34] Determination of nifedipine in dog plasma by high-performance liquid chromatography with tandem mass spectrometric detection
    Pan, Xigui
    Zhou, Shunchang
    Fu, Qinqin
    Hu, Xianming
    Wu, Jianhong
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (07) : 1036 - 1040
  • [35] SULFASALAZINE INTERFERENCE WITH HPLC ASSAY OF 5-HYDROXYINDOLE-3-ACETIC ACID
    COWARD, S
    BOA, FG
    SHERWOOD, RA
    CLINICAL CHEMISTRY, 1995, 41 (05) : 765 - 766
  • [36] High Plasma 5-Hydroxyindole-3-Acetic Acid Concentrations in Subjects With Metabolic Syndrome
    Fukui, Michiaki
    Tanaka, Muhei
    Toda, Hitoshi
    Asano, Mai
    Yamazaki, Masahiro
    Hasegawa, Goji
    Imai, Saeko
    Nakamura, Naoto
    DIABETES CARE, 2012, 35 (01) : 163 - 167
  • [37] ATENOLOL AND PINDOLOL INTERFERE WITH URINARY 5-HYDROXYINDOLE-3-ACETIC ACID
    NEFTEL, KA
    GAUTSCHI, K
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 1986, 24 (02) : 58 - 59
  • [38] Determination of cetirizine in human plasma using high performance liquid chromatography coupled with tandem mass spectrometric detection: application to a bioequivalence study
    Ren, Xiao-Lei
    Tian, Yuan
    Zhang, Zun-Jian
    Chen, Yun
    Wu, Li-Li
    Huang, Jun
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (05): : 287 - 295
  • [39] Quantitative determination of plant phenolics in Urtica dioica extracts by high-performance liquid chromatography coupled with tandem mass spectrometric detection
    Orcic, Dejan
    Franciskovic, Marina
    Bekvalac, Kristina
    Svircev, Emilija
    Beara, Ivana
    Lesjak, Marija
    Mimica-Dukic, Neda
    FOOD CHEMISTRY, 2014, 143 : 48 - 53
  • [40] Determination of dexmedetomidine in human plasma using high performance liquid chromatography coupled with tandem mass spectrometric detection: Application to a pharmacokinetic study
    Li, Wenjing
    Zhang, Zunjian
    Wu, Lili
    Tian, Yuan
    Feng, Shudan
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 897 - 904