Experimental study of dynamic bond behaviour between corroded steel reinforcement and concrete

被引:15
|
作者
Liu, Yu [1 ]
Hao, Hong [2 ]
Hao, Yifei [3 ]
Cui, Jian [4 ]
机构
[1] Guangzhou Univ, Curtin Univ, Joint Res Ctr Struct Monitoring & Protect Multidyn, Sch Civil Engn, Guangzhou, Peoples R China
[2] Curtin Univ, Guangzhou Univ, Joint Res Ctr Struct Monitoring & Prot Multidynam, Sch Civil & Mech Engn, Perth, WA, Australia
[3] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin, Peoples R China
[4] Tianjin Univ, Sch Civil Engn, Key Lab Coast Civil Struct Safety Minist Educ, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete; Reinforcement; Bond strength; Strain rate; Corrosion; CORROSION; STRENGTH; CRACKING; REBAR; BARS; PREDICTION; COVER;
D O I
10.1016/j.conbuildmat.2022.129272
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion damage of steel reinforcement is detrimental to the load-carrying capacity of reinforced concrete structures because it not only reduces the cross sectional area and strength of reinforcement bars, but also weakens the bond between reinforcement and concrete. Many studies have investigated the effects of corrosion on reinforcement loss and static bond strength between reinforcement and concrete, but no study of the influence of corrosion damage on dynamic bond strength has been reported yet. In this study, laboratory tests were conducted to investigate the effect of corrosion on the bond behaviour between steel reinforcement and concrete subjected to high rate dynamic load. Accelerated corrosion damage was induced to steel bars embedded in concrete specimens under laboratory condition. The bond parameters of steel reinforcement and concrete including the ultimate bonding load and bond-slip relationship corresponding to the various strain rates and corrosion degrees were obtained through dynamic pull-out tests. The empirical formulae of dynamic increase factors (DIFs) of the ultimate bonding strength corresponding to different corrosion levels and strain rates were proposed. The experimental results show that the strain rate effect on bonding behaviour is prominent irre-spective of the corrosion level. The increase in the ultimate bonding strength with strain rate for the heavily corroded reinforcement (eta = 5 %-10 %) is more prominent than that for the slightly corroded reinforcement (eta = 0 %-5%). The decrease in the ultimate pull-out force caused by the corrosion damage at high strain rate is more pronounced than that at low strain rate. Corrosion-induced crack and the tensile strength of concrete have significant effect on both the static and dynamic bond behaviours. The results presented in the paper can be used for better modelling and prediction of the responses of corroded reinforced concrete structures subjected to dynamic loads.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental Analysis of Bond between Corroded Steel Bar and Concrete Confined with Textile-Reinforced Concrete
    Yin, Shiping
    Jing, Lei
    Lv, Henglin
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (10)
  • [22] Bond degradation between corroded stainless steel bar and concrete
    Wang H.-L.
    Wu Y.-J.
    Ling J.-Y.
    Sun X.-Y.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2020, 54 (05): : 843 - 850
  • [23] Effect of confinement on bond between corroded steel bars and concrete
    Fang, C.
    ISISS 2005: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOL 1-3, 2005, : 934 - 943
  • [24] Experimental study and analytical model of the bond behavior of corroded reinforcing steel bars in concrete
    Zheng, Yue
    Zheng, Shan-Suo
    Yang, Lu
    Dong, Li-Guo
    Zhang, Yi-Bo
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 327
  • [25] Experimental Study on Bond Behavior of Corroded Steel Bar to Concrete Under Reciprocating Load
    Shang H.
    Chai X.
    Cailiao Daobao/Materials Reports, 2023, 37 (01):
  • [26] Bond of Corroded Reinforcement in Concrete Wrapped with CFRP
    Dai, Xiaodong
    Kou, Xinjian
    Cai, Ningsheng
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1765 - +
  • [27] Bond behaviour between CFRP plates and corroded steel plates
    Li, Anbang
    Xu, Shanhua
    Wang, Hao
    Zhang, Huifeng
    Wang, Yan
    COMPOSITE STRUCTURES, 2019, 220 : 221 - 235
  • [28] Experimental study on bond behavior between concrete and FRP reinforcement
    Pellegrino, Carlo
    Tinazzi, Davide
    Modena, Claudio
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (02) : 180 - 189
  • [29] Experimental study on the bond strength of corroded reinforced concrete
    Chen, Z. H.
    Tan, D. Y.
    Zeng, Y.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 248 - 252
  • [30] Experimental research on the bonding between corroded reinforcement bar and concrete
    Wu, Qing
    Yuan, Ying-Shu
    Jiang, Jian-Hua
    Zhu, Jin
    Jiang, Jing
    Zhongguo Kuangye Daxue Xuebao/Journal of China University of Mining and Technology, 2009, 38 (05): : 685 - 691