Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours

被引:10
|
作者
Jordi Juan-Senabre, Xavier [3 ]
Lopez-Tarjuelo, Juan [3 ]
Conde-Moreno, Antonio [2 ]
Santos-Serra, Agustin [3 ]
Sanchez-Iglesias, Angel L. [2 ]
David Quiros-Higueras, Juan [3 ]
de Marco Blancas, Noelia [3 ]
Calzada-Feliu, Salvador [3 ]
Ferrer-Albiach, Carlos [1 ]
机构
[1] Consorcio Hosp Prov Castello, Inst Oncol, Inst Canc, ES-12002 Castellon De La Plana, Spain
[2] Consorcio Hosp Prov Castello, Inst Oncol, Dept Radiat Oncol, ES-12002 Castellon De La Plana, Spain
[3] Consorcio Hosp Prov Castello, Inst Oncol, Dept Med Phys, ES-12002 Castellon De La Plana, Spain
来源
CLINICAL & TRANSLATIONAL ONCOLOGY | 2011年 / 13卷 / 11期
关键词
Image-guided radiotherapy (IGRT); Systematic and random uncertainties; CTV to PTV margin; Prostate carcinoma; Head and neck carcinoma; SETUP ERROR; COMPUTED-TOMOGRAPHY; ONLINE CORRECTION; RADIOTHERAPY; MOTION; KILOVOLTAGE; INTRAFRACTION; LOCALIZATION; MANAGEMENT; PROTOCOL;
D O I
10.1007/s12094-011-0740-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. An Elekta SynergyA (R) linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis.
引用
收藏
页码:819 / 825
页数:7
相关论文
共 50 条
  • [1] Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours
    Xavier Jordi Juan-Senabre
    Juan López-Tarjuelo
    Antonio Conde-Moreno
    Agustín Santos-Serra
    Ángel L. Sánchez-Iglesias
    Juan David Quirós-Higueras
    Noelia de Marco Blancas
    Salvador Calzada-Feliu
    Carlos Ferrer-Albiach
    Clinical and Translational Oncology, 2011, 13 : 819 - 825
  • [2] QUANTITATIVE ASSESSMENT OF INTERFRACTION UNCERTAINTIES AND CTV TO PTV MARGINS USING CONE BEAM CT TECHNIQUE WITH FIDUCIARY MARKERS. CLINICAL APPLICATION TO PROSTATE AND HEAD & NECK IRRADIATION TUMOURS
    Santos Serra, A.
    Juan-Senabre, X. J.
    Rodriguez-Cordon, M.
    Sanchez Iglesias, A. L.
    Conde-Moreno, A. J.
    Lopez-Tarjuelo, J.
    Quiros-Higueras, J. D.
    Calzada-Feliu, S.
    Ferrer Albiach, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S441 - S441
  • [3] CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans
    Luis A. Pérez-Romasanta
    Eva Lozano-Martín
    Joaquín Velasco-Jiménez
    Fermín Mendicote-León
    Miguel Sanz-Martín
    Javier Torres-Donaire
    Carmen Carrascosa-Fernández
    Juan Carlos Zapata-Jiménez
    Jacinto Arjona-Gutiérrez
    Antonio Gil-Agudo
    Clinical and Translational Oncology, 2009, 11 : 615 - 621
  • [4] CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans
    Perez-Romasanta, Luis A.
    Lozano-Martin, Eva
    Velasco-Jimenez, Joaquin
    Mendicote-Leon, Fermin
    Sanz-Martin, Miguel
    Torres-Donaire, Javier
    Carrascosa-Fernandez, Carmen
    Zapata-Jimenez, Juan Carlos
    Arjona-Gutierrez, Jacinto
    Gil-Agudo, Antonio
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2009, 11 (09): : 615 - 621
  • [5] Evaluation of setup margins using cone-beam CT for prostate and pelvic nodes irradiation
    Van Nunen, A.
    Budiharto, T.
    De Vocht, B.
    Schuring, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S556 - S556
  • [6] Clinical Implementation of Intraoperative Cone-Beam CT in Head and Neck Surgery
    Daly, M. J.
    Chan, H.
    Nithiananthan, S.
    Qiu, J.
    Barker, E.
    Bachar, G.
    Dixon, B. J.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [7] CTV-To-PTV margins for prostate irradiations, a quantitative assessment using novel voxel tracking techniques
    Meijer, G. J.
    de Klerk, J.
    Bzdusek, K.
    Kaus, M. R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2647 - 2648
  • [8] Quantitative Performance Evaluation of Mobile Cone-Beam CT for Head and Neck Imaging
    Thongvigitmanee, Saowapak S.
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Wangkaoom, Kongyot
    Kiang-ia, Atthasak
    Jitsaard, Jaturong
    Chunkiri, Thossapol
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 63 - 67
  • [9] Is application of a quantitative CT technique helpful for quantitative measurement of bone density using dental cone-beam CT?
    Nishikawa, Keiichi
    Kousuge, Yuuji
    Sano, Tsukasa
    ORAL RADIOLOGY, 2016, 32 (01) : 9 - 13
  • [10] Is application of a quantitative CT technique helpful for quantitative measurement of bone density using dental cone-beam CT?
    Keiichi Nishikawa
    Yuuji Kousuge
    Tsukasa Sano
    Oral Radiology, 2016, 32 : 9 - 13