Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours

被引:10
|
作者
Jordi Juan-Senabre, Xavier [3 ]
Lopez-Tarjuelo, Juan [3 ]
Conde-Moreno, Antonio [2 ]
Santos-Serra, Agustin [3 ]
Sanchez-Iglesias, Angel L. [2 ]
David Quiros-Higueras, Juan [3 ]
de Marco Blancas, Noelia [3 ]
Calzada-Feliu, Salvador [3 ]
Ferrer-Albiach, Carlos [1 ]
机构
[1] Consorcio Hosp Prov Castello, Inst Oncol, Inst Canc, ES-12002 Castellon De La Plana, Spain
[2] Consorcio Hosp Prov Castello, Inst Oncol, Dept Radiat Oncol, ES-12002 Castellon De La Plana, Spain
[3] Consorcio Hosp Prov Castello, Inst Oncol, Dept Med Phys, ES-12002 Castellon De La Plana, Spain
来源
CLINICAL & TRANSLATIONAL ONCOLOGY | 2011年 / 13卷 / 11期
关键词
Image-guided radiotherapy (IGRT); Systematic and random uncertainties; CTV to PTV margin; Prostate carcinoma; Head and neck carcinoma; SETUP ERROR; COMPUTED-TOMOGRAPHY; ONLINE CORRECTION; RADIOTHERAPY; MOTION; KILOVOLTAGE; INTRAFRACTION; LOCALIZATION; MANAGEMENT; PROTOCOL;
D O I
10.1007/s12094-011-0740-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. An Elekta SynergyA (R) linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis.
引用
收藏
页码:819 / 825
页数:7
相关论文
共 50 条
  • [31] The feasibility of cone-beam CT for assessment of changes in volume and dose parameters for salivary glands during head and neck IMRT
    Elstroem, U. V.
    Buus, S.
    Muren, L. P.
    Petersen, J. B.
    Grau, C.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S9 - S9
  • [32] CONE-BEAM CT ASSESSMENT OF INTERFRACTION AND INTRAFRACTION SETUP ERROR OF TWO HEAD-AND-NECK CANCER THERMOPLASTIC MASKS
    Velec, Michael
    Waldron, John N.
    O'Sullivan, Brian
    Bayley, Andrew
    Cummings, Bernard
    Kim, John J.
    Ringash, Jolie
    Breen, Stephen L.
    Lockwood, Gina A.
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : 949 - 955
  • [33] Robust Quantitative Assessment of Trabecular Microarchitecture in Extremity Cone-Beam CT Using Optimized Segmentation Algorithms
    Brehler, M.
    Cao, Q.
    Moseley, K. F.
    Osgood, G.
    Morris, C.
    Demehri, S.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [34] Cone-beam CT for image-guided head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    Daly, M.
    Siewerdsen, J.
    Moseley, D.
    Jaffray, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229
  • [35] Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT
    Nardi, Cosimo
    Talamonti, Cinzia
    Pallotta, Stefania
    Saletti, Paola
    Calistri, Linda
    Cordopatri, Cesare
    Colagrande, Stefano
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (07)
  • [36] Dose-guided radiation therapy for head and neck treatments using megavoltage cone-beam CT: A pilot study
    Aubry, J-F.
    Millender, L.
    Morin, O.
    Aubin, M.
    Beaulieu, L.
    Pouliot, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S26 - S26
  • [37] Tracking Changes in Head-and-Neck Rotation and Flexion Using Megavoltage Cone-Beam CT and Deformable Image Registration
    Chen, J.
    Yom, S.
    Ueda, U.
    Quivey, J.
    Aubin, M.
    Pouliot, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [38] Predicting response to radiotherapy of head and neck squamous cell carcinoma using radiomics from cone-beam CT images
    Sellami, S.
    Bourbonne, V
    Hatt, M.
    Tixier, F.
    Bouzid, D.
    Lucia, F.
    Pradier, O.
    Goasduff, G.
    Visvikis, D.
    Schick, U.
    ACTA ONCOLOGICA, 2022, 61 (01) : 73 - 80
  • [39] Evaluation of Dose Calculation Based on Cone-Beam CT Using Different Measuring Correction Methods for Head and Neck Cancer Patients
    Gong, Hanshun
    Liu, Bo
    Zhang, Gaolong
    Dai, Xiangkun
    Qu, Baolin
    Cai, Boning
    Xie, Chuanbin
    Xu, Shouping
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [40] Feasibility of adaptive image-guided IMRT for head and neck cancer using cone-beam CT obtained at the treatment couch
    Elstram, U. V.
    Petersen, JB.
    Poulsen, P. R.
    Grau, C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S219 - S219