Magnetic testing method and apparatus for storage tank floor

被引:0
|
作者
Wu, XJ [1 ]
Sun, GZ [1 ]
Kang, YH [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Peoples R China
关键词
nondestructive testing; magnetic flux leakage testing; magnetic flux testing; tank floor;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the critical areas of integrity testing is that of storage tank floor in the petrochemical industry. Examination of tank floor traditionally depended mainly upon ultrasonic and magnetic particle test methods. The two methods required slow and painstaking application. Therefore, they have been limited to spot testing only. Based on the principle of the magnetic testing, the magnetic testing method and apparatus for storage tank floor are proposed. The whole magnetic testing apparatus includes detector, photoelectric pulse encoder, scanner unit, computer aided signal processing unit, alarm, and so on. The detector contains permanent magnets and Hall sensors. As the detector moves by the scanner, it magnetizes the tank floor Any damages cause distortion in the magnetic field and this distortion can then be detected by the Hall elements. The Hall elements send the information to the computer for analysis. At the same time, the photoelectric pulse encoder recorder the distance from the start point to locate the discontinuity in space domain. Any damages are detected, the alarm unit can send out different light according to the extent of the damage. Two different types of scanner have been developed. One type of scanner is driven by motor and it can pull the larger detector that can inspect 300mm wide in one time. Another is driven by manpower and it can pull the smaller detector that can inspect 150mm wide only. But the smaller scanner can detect the area that the larger scanner difficult to arrive. Sensing system are non-contacted and not affected by scale, oil, mud, paraffin and water It can detect most of test coverage of the tank floor within a reasonable test time. Experimental and field testing have show that as low as 10 percents tank floor wall thickness loss can be located using the magnetic testing system.
引用
收藏
页码:2902 / 2905
页数:4
相关论文
共 50 条
  • [11] The method and apparatus of magnetic nondestructive testing for boller waterwall tube
    Song, XC
    Wu, XJ
    Kang, YH
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 642 - 646
  • [12] A NEW METHOD FOR FAST TANK FLOOR INSPECTION
    YOU, ZQ
    BAUER, D
    MATERIALS PERFORMANCE, 1995, 34 (05) : 55 - 58
  • [14] Application of Zero-phase Digital Filter in Magnetic Flux Leakage Testing for Tank Floor Inspection
    Liu, Fujun
    Ling, Zhangwei
    Kong, Shuai
    Zheng, Mulin
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 1644 - 1648
  • [15] Evaluation of the acoustic emission monitoring method for stress corrosion cracking on aboveground storage tank floor steel
    Bi, Haisheng
    Li, Huiyao
    Zhang, Wei
    Wang, Lin
    Zhang, Qinglei
    Cao, Suzhen
    Toku-Gyamerah, Isaac
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2020, 179
  • [16] Acoustic emission testing of repaired storage tank
    Kwon, JR
    Lyu, GJ
    Lee, TH
    Kim, JY
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2001, 78 (05) : 373 - 378
  • [17] The Construction of Heat Storage Performance Testing Method of Wood Materials used for Floor Heating
    Liu, Cungen
    Luo, Rui
    Zhou, Shiyu
    Du, Guangyue
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3804 - 3810
  • [18] Magnetic flux leakage applied to tank floor inspection - Response
    Amos, DM
    INSIGHT, 1997, 39 (01) : 40 - 41
  • [19] Magnetic Flux Leakage Scanning Velocities for Tank Floor Inspection
    Pullen, Ashley Laurent
    Charlton, Peter C.
    Pearson, Neil R.
    Whitehead, Nicola J.
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (09)
  • [20] CONCRETE OIL STORAGE TANK PLACED ON NORTH-SEA FLOOR
    GERWICK, BC
    HOGNESTA.E
    CIVIL ENGINEERING, 1973, 43 (08): : 81 - 85