Stereotactic localization of the human pedunculopontine nucleus: atlas-based coordinates and validation of a magnetic resonance imaging protocol for direct localization

被引:132
|
作者
Zrinzo, Ludvic [1 ,2 ]
Zrinzo, Laurence V. [3 ]
Tisch, Stephen [1 ]
Limousin, Patricia Dowsey [1 ]
Yousry, Tarek A. [4 ]
Afshar, Farhad [5 ]
Hariz, Marwan I. [1 ,6 ]
机构
[1] UCL, Inst Neurol, Unit Funct Neurosurg, London WC1N 3BG, England
[2] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, London WC1N 3BG, England
[3] Univ Malta, Dept Anat Genet & Cell Biol, Msida 2080, MSD, Malta
[4] Natl Hosp Neurol & Neurosurg, Lysholm Dept Radiol, London WC1N 3BG, England
[5] Royal London Hosp, Barts & London Ctr Neurosci, Dept Neurosurg, London E1 1BB, England
[6] Umea Univ Hosp, Dept Neurosurg, S-90815 Umea, Sweden
关键词
pedunculopontine nucleus; stereotactic localization; deep brain stimulation;
D O I
10.1093/brain/awn075
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The pedunculopontine nucleus (PPN) is a promising new target for deep brain stimulation (DBS) in parkinsonian patients with gait disturbance and postural instability refractory to other treatment modalities. This region of the brain is unfamiliar territory to most functional neurosurgeons. This paper reviews the anatomy of the human PPN and describes novel, clinically relevant methods for the atlas-based and MRI-based localization of the nucleus. These two methods of PPN localization are evaluated and compared on stereotactic MRI data acquired from a diverse group of 12 patients undergoing implantation of deep brain electrodes at sites other than the PPN. Atlas-based coordinates of the rostral and caudal PPN poles in relation to fourth ventricular landmarks were established by amalgamating information sourced from two published human brain atlases. These landmarks were identified on acquired T1 images and atlas-derived coordinates used to plot the predicted PPN location on all 24 sides. Images acquired using a specifically modified, proton-density MRI protocol were available for each patient and were spatially fused to the T1 images. This widely available and rapid protocol provided excellent definition between gray and white matter within the region of interest. Together with an understanding of the regional anatomy, direct localization of the PPN was possible on all 24 sides. The coordinates for each directly localized nucleus were measured in relation to third and fourth ventricular landmarks. The mean (SD) of the directly localized PPN midpoints was 6.4 mm (0.5) lateral, 3.5 mm (1.0) posterior and 11.4 mm (1.2) caudal to the posterior commissure in the anterior commissureposterior commissure plane. For the directly localized nucleus, there was similar concordance for the rostral pole of the PPN in relation to third and fourth ventricular landmarks (P > 0.05). For the caudal PPN pole, fourth ventricular landmarks provided greater concordance with reference to the anteroposterior coordinate (P < 0.001). There was a significant difference between localization of the PPN poles as predicted by atlas-based coordinates and direct MRI localization. This difference affected mainly the rostrocaudal coordinates; the mean lateral and anteroposterior coordinates of the directly localized PPN poles were within 0.5 mm of the atlas-based predicted values. Our findings provide simple, rapid and precise methods that are of clinical relevance to the atlas-based and direct stereotactic localization of the human PPN. Direct MRI localization may allow greater individual accuracy than that afforded by atlas-based coordinates when localizing the human PPN and may be relevant to groups evaluating the clinical role of PPN DBS.
引用
收藏
页码:1588 / 1598
页数:11
相关论文
共 50 条
  • [21] Measurement of Lead Localization Accuracy Based on Magnetic Resonance Imaging
    He, Changgeng
    Zhang, Feng
    Li, Linze
    Jiang, Changqing
    Li, Luming
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [22] A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system
    Yu, C
    Apuzzo, MLJ
    Zee, CS
    Petrovich, Z
    NEUROSURGERY, 2001, 48 (05) : 1092 - 1098
  • [23] An in vitro study to evaluate the accuracy of stereotactic localization using magnetic resonance imaging by means of the Leksell Stereotactic System
    Gliemroth, J
    Gaebel, C
    Kehler, U
    Grande-Nagel, I
    Missler, U
    Arnold, H
    MINIMALLY INVASIVE NEUROSURGERY, 2002, 45 (01) : 1 - 5
  • [24] Magnetic resonance imaging versus computed tomography for target localization in functional stereotactic neurosurgery - Comments
    Kelly, PJ
    Burchiel, KJ
    Bakay, RAE
    Lozano, AM
    NEUROSURGERY, 1999, 45 (02) : 297 - 298
  • [25] Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization - Comment
    Loeffler, JS
    Kooy, HM
    Chapman, P
    NEUROSURGERY, 1999, 45 (06) : 1430 - 1431
  • [27] Stereotactic Imaging for radiosurgery: Localization accuracy of magnetic resonance imaging and positron emission tomography compared with computed tomography
    Mori, Yoshimasa
    Hayashi, Naoki
    Iwase, Mikio
    Yamada, Masami
    Takikawa, Yukinori
    Uchiyama, Yukio
    Oda, Kyota
    Kaii, Osamu
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2006, 84 (04) : 142 - 146
  • [28] Gray matter alteration in heroin-dependent men: An atlas-based magnetic resonance imaging study
    Shi, Hong
    Liang, Zifei
    Chen, Jiajie
    Li, Wei
    Zhu, Jia
    Li, Yongbin
    Ye, Jianjun
    Zhang, Jiangyang
    Xue, Jiuhua
    Liu, Wei
    Wang, Fan
    Wang, Wei
    Li, Qiang
    He, Xiaohai
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 304
  • [29] Accuracy of Frame-Based Stereotactic Magnetic Resonance Imaging vs Frame-Based Stereotactic Head Computed Tomography Fused With Recent Magnetic Resonance Imaging for Postimplantation Deep Brain Stimulator Lead Localization
    Pezeshkian, Patrick
    DeSalles, Antonio A. F.
    Gorgulho, Alessandra
    Behnke, Eric
    McArthur, David
    Bari, Ausaf
    NEUROSURGERY, 2011, 69 (06) : 1299 - 1306
  • [30] Comparison of atlas- and magnetic-resonance-imaging-based stereotactic targeting of the subthalamic nucleus in the surgical treatment of Parkinson's disease
    Patel, Nikunj K.
    Khan, Sadaquate
    Gill, Steven S.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (03) : 153 - 161