Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: A scanning electron microscopy study

被引:4
|
作者
Ozel, Emre [1 ]
Tuna, Elif Bahar [2 ]
Firatli, Sonmez [3 ]
Firatli, Erhan [4 ]
机构
[1] Kocaeli Univ, Dept Restorat Dent, Fac Dent, TR-41190 Basiskele, Kocaeli, Turkey
[2] Istanbul Univ, Dept Pediat Dent, Fac Dent, Istanbul, Turkey
[3] Istanbul Univ, Dept Orthodont, Fac Dent, Istanbul, Turkey
[4] Istanbul Univ, Dept Periodontol, Fac Dent, Istanbul, Turkey
关键词
Class V cavity; different parameters; Er:YAG laser; microleakage; nanohybrid composite; ER-YAG LASER; STEP POLISHING SYSTEMS; ALUMINUM-GARNET LASER; CAVITY PREPARATION; SURFACE-ROUGHNESS; DIAMOND BUR; MICROLEAKAGE; DENTISTRY;
D O I
10.1002/sca.21292
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this study was to compare different parameters of Er:YAG laser irradiations on the marginal microleakage of Class V resin composite restorations. A total of 45 extracted premolars were selected for the study. Class V cavities prepared on both buccal and lingual surfaces of teeth by Er:YAG laser or bur and divided into nine groups. The occlusal margins were in enamel and the cervical margins were in cementum. Group-1: bur preparation; Group-2: laser preparation (lp) (600mJ/5Hz); Group-3: lp (300mJ/10Hz); Group-4: lp (200mJ/15Hz); Group-5: lp (150mJ/20Hz); Group-6: lp (200mJ/20Hz); Group-7: lp (300mJ/14Hz); Group-8: lp (400mJ/10Hz); Group-9: lp (700mJ/5Hz). All teeth were stored in distilled water at 37 degrees C for 24h, then thermocycled 1,000 times (5-55 degrees C). Five teeth from each group were chosen for the microleakage investigation and two teeth for the scanning electron microscope (SEM) evaluation. Teeth, which were prepared for the microleakage test were immersed in 0.5% methylene blue dye for 24h. After immersing, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests (p<0.05). More microleakage was observed in cervical regions compared to occlusal regions in all groups (p<0.05) except for Group 6 (p>0.05). No significant difference was observed among groups in terms of occlusal and cervical surfaces, separately (p>0.05). It may be concluded that the cavities prepared by Er:YAG laser showed higher degree of microleakage than bur prepared at cervical regions. Different parameters of Er:YAG laser irradiations affected microleakage. SCANNING 38:434-441, 2016. (c) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:434 / 441
页数:8
相关论文
共 50 条
  • [31] Microleakage of Class V Cavities with Different Adhesive Systems Prepared by a Diamond Instrument and Different Parameters of Er:YAG Laser Irradiation
    Attar, Nuray
    Korkmaz, Yonca
    Ozel, Emre
    Bicer, Ceren Ozge
    Firatli, Erhan
    PHOTOMEDICINE AND LASER SURGERY, 2008, 26 (06) : 585 - 591
  • [32] Scanning electron microscopy evaluation of the root canal morphology after Er:YAG laser irradiation
    Todea, Darinca Carmen Marilena
    Luca, Ruxandra Elena
    Balabuc, Cosmin Anton
    Miron, Mariana Ioana
    Locovei, Cosmin
    Mocuta, Daliana Emanuela
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2018, 59 (01): : 269 - 275
  • [33] Scanning electron microscopic study of the effects of Er:YAG laser on root cementum
    Fujii, T
    Baehni, PC
    Kawai, O
    Kawakami, T
    Matsuda, K
    Kowashi, Y
    JOURNAL OF PERIODONTOLOGY, 1998, 69 (11) : 1283 - 1290
  • [34] Influence of Erbium:YAG laser energies on the microleakage of Class V resin-based composite restorations
    Roebuck, EM
    Saunders, WP
    Whitters, CJ
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (05): : 280 - 284
  • [35] ER-YAG laser pretreatment effect on in vitro secondary caries formation around composite restorations
    Ceballos, L
    Toledano, M
    Osorio, R
    García-Godoy, F
    Flaitz, C
    Hicks, J
    AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (01): : 46 - 49
  • [36] Marginal Leakage of Class V Composite Restorations Assessed Using Microcomputed Tomography and Scanning Electron Microscope
    Rengo, C.
    Goracci, C.
    Ametrano, G.
    Chieffi, N.
    Spagnuolo, G.
    Rengo, S.
    Ferrari, M.
    OPERATIVE DENTISTRY, 2015, 40 (04) : 440 - 448
  • [37] Scanning Electron Microscope (SEM) Evaluation of Tooth Surface Irradiated by Different Parameters of Erbium: Yttrium Aluminium Garnet (Er: YAG) Laser
    Nokhbatolfoghahaie, Hanieh
    Chiniforush, Nasim
    Shahabi, Sima
    Monzavi, Abbas
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2012, 3 (02) : 51 - 55
  • [38] Surface Treatment by Different Parameters of Erbium: Yttrium-Aluminum-Garnet (Er:YAG) Laser: Scanning Electron Microscope (SEM) Evaluation
    Chiniforush, Nasim
    Nokhbatolfoghahaei, Hanieh
    Monzavi, Abbas
    Pordel, Edris
    Ashnagar, Sajjad
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2016, 7 (01) : 37 - 39
  • [39] Scanning electron microscopy study on enamel etching with Nd: YAG laser and phosphoric acid
    Eduardo, C.P.
    Cecchini, R.C.M.
    Marques, J.L.L.
    Matsumoto, K.
    Journal of Clinical Laser Medicine and Surgery, 1995, 13 (02):
  • [40] Comparison of Microleakage of Three Adhesive Systems in Class V Composite Restorations Prepared with Er,Cr:YSGG Laser
    Kimyai, Soodabeh
    Ajami, Amir Ahmad
    Chaharom, Mohammad Esmaeel Ebrahimi
    Oskoee, Jafar Sadjadi