Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: A scanning electron microscopy study

被引:4
|
作者
Ozel, Emre [1 ]
Tuna, Elif Bahar [2 ]
Firatli, Sonmez [3 ]
Firatli, Erhan [4 ]
机构
[1] Kocaeli Univ, Dept Restorat Dent, Fac Dent, TR-41190 Basiskele, Kocaeli, Turkey
[2] Istanbul Univ, Dept Pediat Dent, Fac Dent, Istanbul, Turkey
[3] Istanbul Univ, Dept Orthodont, Fac Dent, Istanbul, Turkey
[4] Istanbul Univ, Dept Periodontol, Fac Dent, Istanbul, Turkey
关键词
Class V cavity; different parameters; Er:YAG laser; microleakage; nanohybrid composite; ER-YAG LASER; STEP POLISHING SYSTEMS; ALUMINUM-GARNET LASER; CAVITY PREPARATION; SURFACE-ROUGHNESS; DIAMOND BUR; MICROLEAKAGE; DENTISTRY;
D O I
10.1002/sca.21292
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this study was to compare different parameters of Er:YAG laser irradiations on the marginal microleakage of Class V resin composite restorations. A total of 45 extracted premolars were selected for the study. Class V cavities prepared on both buccal and lingual surfaces of teeth by Er:YAG laser or bur and divided into nine groups. The occlusal margins were in enamel and the cervical margins were in cementum. Group-1: bur preparation; Group-2: laser preparation (lp) (600mJ/5Hz); Group-3: lp (300mJ/10Hz); Group-4: lp (200mJ/15Hz); Group-5: lp (150mJ/20Hz); Group-6: lp (200mJ/20Hz); Group-7: lp (300mJ/14Hz); Group-8: lp (400mJ/10Hz); Group-9: lp (700mJ/5Hz). All teeth were stored in distilled water at 37 degrees C for 24h, then thermocycled 1,000 times (5-55 degrees C). Five teeth from each group were chosen for the microleakage investigation and two teeth for the scanning electron microscope (SEM) evaluation. Teeth, which were prepared for the microleakage test were immersed in 0.5% methylene blue dye for 24h. After immersing, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests (p<0.05). More microleakage was observed in cervical regions compared to occlusal regions in all groups (p<0.05) except for Group 6 (p>0.05). No significant difference was observed among groups in terms of occlusal and cervical surfaces, separately (p>0.05). It may be concluded that the cavities prepared by Er:YAG laser showed higher degree of microleakage than bur prepared at cervical regions. Different parameters of Er:YAG laser irradiations affected microleakage. SCANNING 38:434-441, 2016. (c) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:434 / 441
页数:8
相关论文
共 50 条
  • [1] Comparison of total-etch, self-etch, and selective etching techniques on class V composite restorations prepared by Er:YAG laser and bur: a scanning electron microscopy study
    Ozel, Emre
    Tuna, Elif Bahar
    Firatli, Sonmez
    Firatli, Erhan
    MICROSCOPY RESEARCH AND TECHNIQUE, 2016, 79 (10) : 998 - 1004
  • [2] Microleakage of class V resin composite restorations after conventional and Er:YAG laser preparation
    Delme, KIM
    Deman, PJ
    De Moor, RJG
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (09) : 676 - 685
  • [3] Microleakage in Class V composite resin restorations prepared conventionally and prepared with the Er:YAG laser
    Ramos, A
    Eduardo, CP
    Tanji, E
    Zenzell, D
    INTERNATIONAL LASER CONGRESS: LASERS AT THE DAWN OF THE THIRD MILLENNIUM, 1996, : 257 - 261
  • [4] Microleakage in class V restorations prepared with Er:YAG laser.
    Ramos, ACB
    Eduardo, CP
    Tanji, EY
    Zezell, DM
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 990 - 990
  • [5] Effect of the Nd:YAG and the Er:YAG Laser on the Adhesive-Dentin Interface: A Scanning Electron Microscopy Study
    Ghiggi, Paula Cristine
    Cezarotto Dall Agnol, Rhuy Jacob
    Burnett Junior, Luiz Henrique
    Borges, Gilberto Antonio
    Spohr, Ana Maria
    PHOTOMEDICINE AND LASER SURGERY, 2010, 28 (02) : 195 - 200
  • [6] Assessing microleakage of different class V restorations after Er:YAG laser and bur preparation
    Corona, SAM
    Borsatto, MC
    Pecora, JD
    Rocha, RASD
    Ramos, TS
    Palma-Dibb, RG
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (10) : 1008 - 1014
  • [7] Scanning Electron Microscopy study of cavity preparation with ER:YAG laser.
    Tanji, EY
    Haypek, P
    Groth, EB
    Zezell, DM
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 988 - 988
  • [8] Assessing microleakage of class V resin composite restorations after Er:YAG laser and bur preparation
    Aranha, ACC
    Turbino, ML
    Powell, GL
    Eduardo, CD
    LASERS IN SURGERY AND MEDICINE, 2005, 37 (02) : 172 - 177
  • [9] The effects of cavity-filling techniques on microleakage in class II resin restorations prepared with Er:YAG laser and diamond bur: A scanning electron microscopy study
    Ozel, Emre
    Tuna, Elif Bahar
    Firatli, Erhan
    SCANNING, 2016, 38 (05) : 389 - 395
  • [10] Scanning electron microscopy study of cavity preparation in deciduous teeth using the Er:YAG laser with different powers
    Zhang, Sun
    Chen, Tao
    Ge, Li-hong
    LASERS IN MEDICAL SCIENCE, 2012, 27 (01) : 141 - 144