Using technical specifications for water cooled generator stator rewinds

被引:0
|
作者
Serafin, JD [1 ]
机构
[1] Southern Co, Atlanta, GA 30303 USA
关键词
D O I
10.1109/IEMDC.2001.939303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large number of generators with water cooled stator windings were placed in service in the 1970's. After achieving 25 to 30 years of service, many utilities are entering the market for rewinds. The development of meaningful technical specifications is necessary to set standards for potential bidders. In addition, a clearly defined scope of work within the specification can eliminate surprises and disputes once a bidder has been selected and the work has begun. Finally, technical surveillance by a representative of the utility can be very important as the contractors move to meet competitive demands by reducing the duration and cost of rewinds. This paper will review Southern Company's experience in developing and implementing technical specifications for use during recent stator rewinds.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 50 条
  • [21] Problems with modern air-cooled generator stator winding insulation
    Griffith, G
    Tucker, S
    Milsom, J
    Stone, G
    IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (06) : 6 - 10
  • [22] Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis
    Kim, Hee Soo
    Bae, Yong Chae
    Lee, Wook Ryun
    Lee, Doo Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2010, 34 (09) : 867 - 873
  • [23] WATER-COOLED GENERATOR CONNECTIONS
    ABRAM, L
    GOODALL, J
    WENTWORTH, TG
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (07): : 1185 - +
  • [24] A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions
    Kim, Hee Soo
    Bae, Y. C.
    Kim, Hee Jeong
    Na, Myung Hwan
    KOREAN JOURNAL OF APPLIED STATISTICS, 2009, 22 (05) : 961 - 969
  • [25] Stator core ventilation system of a 1000 MW axially cooled turbine generator
    Hu, Sheng
    Jin, Ru-Lin
    Tan, Fu-Wa
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2002, 36 (07): : 1004 - 1007
  • [26] DISCUSSION ON WATER-COOLED GENERATOR CONNECTIONS
    JAMES, LW
    HEWETT, NB
    HASSALL, RE
    ABRAM, L
    GOODALL, J
    WENTWORT.TG
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (09): : 1850 - &
  • [27] WATER-COOLED STATOR WINDINGS COPPER OXIDE ISSUES
    Maughan, Clyde V.
    Svoboda, Matthias
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 145 - 150
  • [28] Generator - Liquid cooled stator skid instrumentation/runback upgrades - (Case-Study)
    Clark, James W.
    Lake, Les C.
    Martindale, Brian
    Proceedings of the ASME Power Conference 2007, 2007, : 343 - 347
  • [29] Influence of a Novel Stator Teeth Internal Ventilation Structure on Air-Cooled Turbo-Generator Parameters and Stator Temperature
    Liu, Wenmao
    Li, Weili
    Luo, Shifan
    Huang, Xuelian
    Li, Dan
    Li, Zhiqiang
    Xu, Guorui
    IEEE ACCESS, 2020, 8 : 122422 - 122433
  • [30] Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator
    Kim, Hee-Dong
    Kong, Tae-Sik
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1472 - 1475