Using technical specifications for water cooled generator stator rewinds

被引:0
|
作者
Serafin, JD [1 ]
机构
[1] Southern Co, Atlanta, GA 30303 USA
关键词
D O I
10.1109/IEMDC.2001.939303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large number of generators with water cooled stator windings were placed in service in the 1970's. After achieving 25 to 30 years of service, many utilities are entering the market for rewinds. The development of meaningful technical specifications is necessary to set standards for potential bidders. In addition, a clearly defined scope of work within the specification can eliminate surprises and disputes once a bidder has been selected and the work has begun. Finally, technical surveillance by a representative of the utility can be very important as the contractors move to meet competitive demands by reducing the duration and cost of rewinds. This paper will review Southern Company's experience in developing and implementing technical specifications for use during recent stator rewinds.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 50 条
  • [1] Specifying hydro generator stator windings or rewinds
    Iris Power Engineering, Inc., Canada
    Int J Hydropower Dams, 2006, 4 (60-64):
  • [2] Prognostics for Stator Windings of Water-Cooled Generator Against Water Absorption
    Jang, Beom Chan
    Youn, Byeng D.
    Kim, Hee Soo
    Bae, Yong Chae
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2015, 39 (06) : 625 - 629
  • [4] A thermal model for the water-cooled stator bars of the synchronous generator
    Li, JQ
    Li, HM
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 756 - 760
  • [5] Evaluation of mechanical integrity for water cooled generator stator windings in power plants
    Bae, YC
    Kim, HS
    Kim, YW
    Lee, H
    Kim, SH
    SYSTEMS INTEGRITY AND MAINTENANCE, PROCEEDINGS, 2000, : 75 - 80
  • [6] Corrosion and Deposits in Water-Cooled Generator Stator Windings: Overview of Water Cooling of Generators
    Svoboda, Robert
    Blecken, Wolf-Dietrich
    POWERPLANT CHEMISTRY, 2018, 20 (05): : 290 - 294
  • [7] Analysis of Leak and Water Absorption Test Results for Water-Cooled Generator Stator Windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    Lee, Wook-Ryun
    Lee, Doo-Young
    Kim, Hee-Dong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (02) : 230 - 235
  • [8] Health Diagnostics of Water-Cooled Power Generator Stator Windings Using a Directional Mahalanobis Distance (DMD)
    Park, Kyung Min
    Youn, Byeng D.
    Yoon, Joung Taek
    Hu, Chao
    Kim, Hee Soo
    Bae, Yong Chae
    2013 IEEE INTERNATIONAL CONFERENCE ON PROGNOSTICS AND HEALTH MANAGEMENT, 2013,
  • [9] An Experimental Study on the Dryness Judgement Criterion for Water-cooled Generator Stator Windings
    Kim, Hee Soo
    Bae, Yong Chae
    Lee, Wook Ryun
    Lee, Doo Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2010, 34 (02) : 137 - 143
  • [10] Experience on the periodic wet bar diagnosis of water-cooled generator stator windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    BALTICA VIII: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 2, 2010, 265 : 253 - 269