Safety of different electrocautery modes for endoscopic sphincterotomy: a Bayesian network meta-analysis

被引:4
|
作者
Hedjoudje, Abdellah [1 ,2 ]
Cheurfa, Cherifa [3 ]
Farha, Jad [2 ]
Jais, Benedicte [1 ]
Aubert, Alain [1 ]
Lorenzo, Diane [1 ]
Maire, Frederique [1 ]
Badurdeen, Dilhana [2 ]
Kumbhari, Vivek [2 ]
Prat, Frederic [1 ]
机构
[1] Hop Beaujon, AP HP, DMU Digest, Serv Endoscopie Digest, 100 Blvd Gen Leclerc, F-92110 Clichy, France
[2] Johns Hopkins Med Inst, Div Gastroenterol, Baltimore, MD 21205 USA
[3] Univ Paris, Sorbonne Paris Cite Res Ctr, Cochrane France, INSERM,CRESS,UMR1153,Epidemiol & Stat, Paris, France
关键词
electrocautery; electrocoagulation; endoscopic sphincterotomy; endoscopic retrograde cholangiopancreatography; pancreatitis; ELECTROSURGICAL CURRENT; ENDOCUT MODE; PURE-CUT; BILIARY SPHINCTEROTOMY; EUROPEAN-SOCIETY; COMPLICATIONS; PANCREATITIS; RISK; INCONSISTENCY;
D O I
10.1177/26317745211062983
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aims: Post-endoscopic retrograde cholangiopancreatography acute pancreatitis (PAP) and post-sphincterotomy hemorrhage are known adverse events of postendoscopic retrograde cholangiopancreatography. Various electrosurgical currents can be used for endoscopic sphincterotomy. The extent to which this influences adverse events remains unclear. We assessed the comparative safety of different electrosurgical currents, through a Bayesian network meta-analysis of published studies merging direct and indirect comparison of trials. Methods: We performed a Bayesian random-effects network meta-analysis of randomized controlled trials that compared the safety of different electrocautery modes for endoscopic sphincterotomy. Results: Nine studies comparing four electrocautery modes (blended cut, pure cut, endocut, and pure cut followed by blended cut) with a combined enrollment of 1615 patients were included. The pooled results of the network meta-analysis did not show a significant difference in preventing post-sphincterotomy pancreatitis when comparing electrocautery modes. However, pure cut was associated with a statistically significant increased risk of bleeding compared with endocut [relative risk = 4.30; 95% confidence interval (1.53-12.87)]. On the other hand, the pooled results of the network meta-analysis showed no significant difference in prevention of bleeding when comparing blended cut versus endocut, pure cut followed by blended cut versus endocut, pure cut followed by blended cut versus blended cut, pure cut versus blended cut, and pure cut versus pure cut followed by blended cut. The results of rank probability found that endocut was most likely to be ranked the best. Conclusion: No electrocautery mode was superior to another with regard to preventing PAP. Endocut was superior with respect to preventing bleeding. Therefore, we suggest performing endoscopic sphincterotomy with endocut.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Efficacy and Safety of Different Bioactive Coils in Intracranial Aneurysm Interventional Treatment, a Systematic Review and Bayesian Network Meta-Analysis
    Zhang, Jie
    Jiang, Guannan
    Song, Zhaoming
    Cheng, Wei
    Wu, Wenxue
    Chen, Zhouqing
    Wang, Zhong
    You, Wanchun
    Chen, Gang
    BRAIN SCIENCES, 2022, 12 (08)
  • [42] Comparison of efficacy and safety of different fixation devices for anterior cruciate ligament reconstruction A Bayesian network meta-analysis protocol
    Jin, Jiaxin
    Yu, Liping
    Wei, Min
    Shang, Yi
    Wang, Xin
    MEDICINE, 2019, 98 (12)
  • [43] Comparative Safety of Ultrasound Enhancing Agents: A Systematic Review and Bayesian Network Meta-Analysis
    Gonzalez, Ricardo De La Fuente
    Cabra, Arturo
    Liu, Daphne
    Gueco, Myra
    Naslazi, Emi
    Fu, Shuai
    Maliszewska, Zuzanna
    Hummel, Noemi
    Dunham, Dustin M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2025, 237 : 6 - 13
  • [44] Comparative Efficacy and Safety of Thrombolytic Agents for Pulmonary Embolism: A Bayesian Network Meta-Analysis
    Li, Hong-Yan
    Wang, Yong-Bo
    Ren, Xiang-Ying
    Wang, Jing
    Wang, Hai-Shan
    Jin, Ying-Hui
    PHARMACOLOGY, 2023, 108 (02) : 111 - 126
  • [45] Endoscopic gastric plication: a network meta-analysis
    Laopeamthong, Issaree
    Kasetsermwiriya, Wisit
    Techapongsatorn, Suphakarn
    Tansawet, Amarit
    INTERNATIONAL JOURNAL OF SURGERY OPEN, 2024, 62 (01) : 57 - 63
  • [46] Comparison of endoscopic surgical approaches for total thyroidectomy: a systematic review and Bayesian network meta-analysis
    Long, Tengjiang
    Li, Junlei
    Yuan, Yuquan
    Yang, Zeyu
    Xu, Peng
    Pan, Bin
    Sun, Yiceng
    Yin, Supeng
    Zhao, Chengzhi
    Zhang, Fan
    GLAND SURGERY, 2025, 14 (01)
  • [47] A meta-analysis comparing the efficacy and safety of different modes of administration of cream in the treatment of otomycosis
    Fan, Lei
    Xu, Xue-Meng
    Liu, Bi-Yao
    Huang, Jing
    Yan, Da-Zhong
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2024,
  • [48] The efficacy of different segments fixation for treatment thoracolumbar fractures: A Bayesian network meta-analysis
    He, Xiaoyuan
    Zhong, Zhenhao
    Zhou, Wenjie
    Guo, Shasha
    Chen, Huanxiong
    Chen, Tao
    MEDICINE, 2023, 102 (38) : E34830
  • [49] Different lumbar fusion techniques for lumbar spinal stenosis: a Bayesian network meta-analysis
    Wei Li
    Haibin Wei
    Ran Zhang
    BMC Surgery, 23
  • [50] Analgesic effects of different acupuncture therapies on postherpetic neuralgia: a Bayesian network meta-analysis
    CUI Yang
    SUN Zhongren
    ZHOU Xinyu
    ZHANG Shuo
    YIN Hongna
    中国药理学与毒理学杂志, 2023, 37(S1) (S1) : 72 - 72