Smoothing Monte Carlo calculated dose distributions by iterative reduction of noise

被引:17
|
作者
Fippel, M [1 ]
Nüsslin, F [1 ]
机构
[1] Univ Klinikum Tubingen, Abt Med Phys, D-72076 Tubingen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 10期
关键词
D O I
10.1088/0031-9155/48/10/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A smoothing algorithm based on an optimization procedure is presented and evaluated for single electron and photon beams and a full intensity modulated radiation therapy (IMRT) delivery. The algorithm iteratively reduces the statistical noise of Monte Carlo (MC) calculated dose distributions. It is called IRON (iterative reduction of noise). By varying the dose in each voxel, the algorithm minimizes the second partial derivatives of dose with respect to X, Y and Z. An additional restoration term ensures that too large dose changes are prevented. IRON requires a MC calculated one-dimensional or three-dimensional dose distribution with or without known statistical uncertainties as input. The algorithm is tested using three different treatment plan examples, a photon beam dose distribution in water, an IMRT plan of a real patient and an electron beam dose distribution in a water phantom with inhomogeneities. It is shown that smoothing can lead to an additional reduction of MC calculation time by factors of 2 to 10. This is especially useful if MC dose calculation is part of an inverse treatment planning system. In addition to this, it is shown that smoothing a noisy dose distribution may introduce some bias into the final dose values by converting the statistical uncertainty of the dose distribution into a systematic deviation of the dose value.
引用
收藏
页码:1289 / 1304
页数:16
相关论文
共 50 条
  • [21] Denoising of Monte Carlo Dose Distributions Using UNet
    Javaid, U.
    Souris, K.
    Dasnoy, D.
    Montero, A. Barragan
    Huang, S.
    Lee, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E120 - E120
  • [22] EGSnrc Monte Carlo calculated dose distribution around brachytherapy sources
    Tuan, Hoang
    Minh Phuoc Dang
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S175 - S176
  • [23] Comparison of treatment planning system and Monte Carlo calculated dose distributions in an extreme water-lung interface phantom
    Gagne, I.
    Zavgorodni, S.
    [J]. MEDICAL PHYSICS, 2006, 33 (07) : 2657 - 2658
  • [24] DISTRIBUTIONS OF ABSORBED DOSE FROM PI-MESON BEAMS CALCULATED FROM A NEW MONTE-CARLO PROGRAM
    BUCHE, G
    PRZYBILLA, G
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (02): : 321 - 341
  • [25] Measured, Calculated and Monte Carlo Simulated Dose Distributions in a Unique Gold Applicator Loaded with I-125 Seeds
    Trauernicht, C.
    Hering, E.
    Du Plessis, F.
    Maree, G.
    Van Eeden, D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E812 - E813
  • [26] Influence of initial electron beam characteristics on Monte Carlo calculated absorbed dose distributions for linear accelerator electron beams
    Björk, P
    Knöös, T
    Nilsson, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4019 - 4041
  • [27] Iterative Determination of Distributions by the Monte Carlo Method in Problems with an External Source
    Makai, Mihaly
    Szatmary, Zoltan
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2014, 177 (01) : 52 - 67
  • [28] Iterative Monte Carlo analysis of spin-dependent parton distributions
    Sato, Nobuo
    Melnitchouk, W.
    Kuhn, S. E.
    Ethier, J. J.
    Accardi, A.
    [J]. PHYSICAL REVIEW D, 2016, 93 (07)
  • [29] Nonlinear noise reduction through Monte Carlo sampling
    Davies, ME
    [J]. CHAOS, 1998, 8 (04) : 775 - 781
  • [30] ELECTRON DOSE DISTRIBUTIONS IN INHOMOGENEOUS PHANTOMS: A MONTE CARLO STUDY
    Mihailescu, D.
    Borcia, C.
    [J]. ROMANIAN REPORTS IN PHYSICS, 2018, 70 (03)