An Automatic Wideband 90 ° Phase Shifter for Optically Pumped Cesium Magnetometers

被引:10
|
作者
Huang, Yuefei [1 ,2 ,3 ]
Ge, Jian [1 ,2 ,3 ]
Dong, Haobin [1 ,2 ,3 ]
Liu, Huan [1 ,2 ,3 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Hubei, Peoples R China
[2] Hubei Key Lab Adv Control & Intelligent Automat C, Wuhan 430074, Hubei, Peoples R China
[3] Sci & Technol Near Surface Detect Lab, Wuxi 214035, Peoples R China
关键词
Optically-pumped cesium magnetometer; 90 degrees phase shifter; resonant frequency; automatic; wideband;
D O I
10.1109/JSEN.2017.2764477
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An automatic wideband 90 degrees phase shifter for optically pumped cesium magnetometer has been investigated experimentally. As an important part of the self- oscillating optically pumped cesium magnetometer detecting circuit, the band and automation of the phase shifter directly affect the continuous measurement of the magnetic field. At the same time, a phase deviation of 1 degrees will cause 1 Hz change of the resonant frequency. In order to meet the continuous measurement of the geomagnetic field, an automatic wideband 90 degrees phase shifter based on the allpass filter has been designed. It can be used to precisely make the phase of the detected signal shifted by 90 degrees in a wide range of frequencies from 50 to 350 kHz. Through the actual test and analysis, the phase shift error of the automatic phase shifter is less than 0.1 degrees, and the relative error less than 0.1%. It has been proved the feasibility of the automatic wideband 90 degrees phase shifter applied to the cesium optically pumped magnetometer.
引用
收藏
页码:7928 / 7934
页数:7
相关论文
共 50 条
  • [21] SPIN RELAXATION OF OPTICALLY PUMPED CESIUM
    FRANZ, FA
    LUSCHER, E
    PHYSICAL REVIEW, 1964, 135 (3A): : A582 - +
  • [22] Optimal Operating Temperature of Miniaturized Optically Pumped Magnetometers
    Zhang, Shaowen
    Lu, Jixi
    Ye, Mao
    Zhou, Ying
    Yin, Kaifeng
    Lu, Fei
    Yan, Yeguang
    Zhai, Yueyang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [23] Optically pumped magnetometers based on pseudo-random-bit-sequence phase modulation
    Ma, Ning
    Duan, Lihong
    Fang, Xiujie
    Xing, Bozheng
    Ma, Danyue
    Lu, Jixi
    Han, Bangcheng
    APPLIED PHYSICS LETTERS, 2023, 123 (07)
  • [24] Multichannel MEG with microfabricated optically-pumped magnetometers
    Sander, T. H.
    Alem, O.
    Kitching, J.
    Trahms, L.
    Knappe, S.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S637 - S637
  • [25] Design of Wideband 90° Phase Shifter for Optical Pumping Magnetic Sensor
    Tan, Chao
    Huang, Yue-hua
    Zhang, Hai-bin
    INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (EEE 2014), 2014, : 12 - 16
  • [26] Microfabricated Optically-Pumped Magnetometers for Biomagnetic Applications
    Knappe, Svenja
    Alem, Orang
    Sheng, Dong
    Kitching, John
    8TH SYMPOSIUM ON FREQUENCY STANDARDS AND METROLOGY 2015, 2016, 723
  • [27] Discrimination of finger movements by magnetomyography with optically pumped magnetometers
    Antonino Greco
    Sangyeob Baek
    Thomas Middelmann
    Carsten Mehring
    Christoph Braun
    Justus Marquetand
    Markus Siegel
    Scientific Reports, 13 (1)
  • [28] OPTICALLY PUMPED ATOMIC MAGNETOMETERS AFTER 3 DECADES
    ALEXANDROV, EB
    BONCHBRUEVICH, VA
    OPTICAL ENGINEERING, 1992, 31 (04) : 711 - 717
  • [29] Design and implementation of the automatic phase compensation in optically pumped magnetometer
    Huang, Yuefei
    Dong, Haobin
    Ge, Jian
    Guo, Peipei
    PROCEEDINGS FIRST INTERNATIONAL CONFERENCE ON ELECTRONICS INSTRUMENTATION & INFORMATION SYSTEMS (EIIS 2017), 2017, : 526 - 531
  • [30] Optically pumped magnetometers enable a new level of biomagnetic measurements
    Sander, Tilmann
    Jodko-Wladzinska, Anna
    Hartwig, Stefan
    Bruehl, Ruediger
    Middelmann, Thomas
    ADVANCED OPTICAL TECHNOLOGIES, 2020, 9 (05) : 247 - 251