Differential in vivo urodynamic measurement in a single thin catheter based on two optical fiber pressure sensors

被引:29
|
作者
Poeggel, Sven [1 ]
Duraibabu, Dineshbabu [1 ]
Tosi, Daniele [1 ,2 ]
Leen, Gabriel [1 ]
Lewis, Elfed [1 ]
McGrath, Deirdre [3 ]
Fusco, Ferdinando [4 ]
Sannino, Simone [4 ]
Lupoli, Laura [4 ]
Ippolito, Juliet [4 ]
Mirone, Vincenzo [4 ]
机构
[1] Univ Limerick, Dept Elect & Comp Engn, Opt Fibre Sensors Res Ctr, Limerick 00000, Ireland
[2] Nazarbayev Univ, Sch Engn Elect & Elect Engn, Astana 010000, Kazakhstan
[3] Univ Limerick, Grad Entry Med Sch, Fac Educ & Hlth Sci, Limerick 00000, Ireland
[4] Univ Naples Federico II, Scuola Med & Chirurgia, Urol Clin, I-80121 Naples, Italy
基金
爱尔兰科学基金会;
关键词
optical fiber pressure sensors; in vivo; urodynamic; pressure; differential; catheter; Fabry-Perot interferometer; fiber Bragg grating;
D O I
10.1117/1.JBO.20.3.037005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Urodynamic analysis is the predominant method for evaluating dysfunctions in the lower urinary tract. The exam measures the pressure during the filling and voiding process of the bladder and is mainly interested in the contraction of the bladder muscles. The data arising out of these pressure measurements enables the urologist to arrive at a precise diagnosis and prescribe an adequate treatment. A technique based on two optical fiber pressure and temperature sensors with a resolution of better than 0.1 cm H2O (similar to 10 Pa), a stability better than 1 cm H2O/hour, and a diameter of 0.2 mm in a miniature catheter with a diameter of only 5 Fr (1.67 mm), was used. This technique was tested in vivo on four patients with a real-time urodynamic measurement system. The optical system presented showed a very good correlation to two commercially available medical reference sensors. Furthermore, the optical urodynamic system demonstrated a higher dynamic and better sensitivity to detect small obstructions than both pre-existing medical systems currently in use in the urodynamic field. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Single optical channel based Raman distributed optical fiber temperature measurement system
    Feng, Yuxiang
    Liu, Zhikai
    Huang, Minnan
    Wang, Yishan
    Lyu, Lidong
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (17): : 2645 - 2653
  • [42] Flexible Ultra-Thin Nanocomposite Based Piezoresistive Pressure Sensors for Foot Pressure Distribution Measurement
    Rajendran, Dhivakar
    Ramalingame, Rajarajan
    Palaniyappan, Saravanan
    Wagner, Guntram
    Kanoun, Olfa
    SENSORS, 2021, 21 (18)
  • [43] A Disturbance-Blanking Optical Measurement System Based on Fiber Bragg Grating Sensors
    Roessner, Max R.
    Hesske, Andre
    Kin, Vitali
    Koch, Alexander W.
    TM-TECHNISCHES MESSEN, 2013, 80 (04) : 135 - 139
  • [44] Heterogeneous measurement system based on optical fiber and ultrasonic sensors to determine ethanol concentration
    Collere Possetti, Gustavo Rafael
    Terada, Galileu Godoy
    Daciuk, Rafael Jose
    Ofuchi, Cesar Yutaka
    Neves Junior, Flavio
    Ramos de Arruda, Lucia Valeria
    Muller, Marcia
    Fabris, Jose Luis
    2011 IEEE SENSORS, 2011, : 1169 - 1172
  • [45] Design of optical fiber Bragg grating-based sensors for flow measurement in pipes
    Dieguez, Pedro
    Rodriguez, Armando
    Urroz, Jose Carlos
    Lopez, Javier
    Lopez-Amo, Manuel
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2023, 17 (01)
  • [46] MEASUREMENT OF THE DEFORMATION FIELD FOR MACHINE TOOL BASED ON OPTICAL FIBER BRAGG GRATING SENSORS
    Liu, Yi
    Liu, Mingyao
    Yi, Chongxiang
    Chen, Ming
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON INNOVATIVE DESIGN AND MANUFACTURING (ICIDM), 2014, : 222 - 226
  • [47] Initial experience with a thin single segment pressure and conductance catheter for measurement of left ventricular. volume
    Carlsson, C
    Söderqvist, E
    Brodin, LÅ
    Källner, G
    Hultman, J
    Elmqvist, H
    Saha, S
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 103 - 106
  • [48] Optical fiber based pressure sensors developed for monitoring vehicle loads of asphalt pavements
    Wang, Hua-ping
    Guo, Yan-xin
    Li, Qi-ming
    Feng, Si-Yuan
    Gong, Xiang-Shu
    Jing, Xin
    OPTICS FRONTIERS ONLINE 2020: DISTRIBUTED OPTICAL FIBER SENSING TECHNOLOGY AND APPLICATIONS, 2021, 11607
  • [49] An optical fiber sensor for the simultaneous measurement of pressure and position based on a pair of fiber Bragg gratings
    Wang, Bo-yuan
    Cai, Lu
    Zhao, Yong
    OPTICAL FIBER TECHNOLOGY, 2021, 67
  • [50] COMPARISON OF WATER LEVEL MEASUREMENT PERFORMANCE FOR TWO DIFFERENT TYPES OF DIAPHRAGM USING FIBER BRAGG GRATING BASED OPTICAL SENSORS
    Ameen, Odai Falah
    Younus, Marwan Hafeedh
    Ibrahim, R. K. Raja
    Rahman, Rosly Abdul
    JURNAL TEKNOLOGI, 2016, 78 (6-11): : 97 - 101