Measurement and Monte Carlo modeling of the spatial response of scintillation screens

被引:3
|
作者
Pistrui-Maximean, S. A. [1 ]
Letang, J. M.
Freud, N.
Koch, A.
Walenta, A. H.
Montarou, G.
Babot, D.
机构
[1] Inst Natl Sci Appl, CNDRI, NDT Lab, F-69621 Villeurbanne, France
[2] Thales Electron Devices, F-38430 Moirans, France
[3] Univ Siegen, FB Phys, Detectors & Elect Dept, D-57068 Siegen, Germany
[4] Univ Blaise Pascal, Corpuscular Phys Lab, F-63177 Aubiere, France
关键词
phosphor screen; X-ray imaging; modulation transfer function (MTF); slit method; Monte Carlo simulation; geant4;
D O I
10.1016/j.nima.2007.07.153
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this article, we propose a detailed protocol to carry out measurements of the spatial response of scintillation screens and to assess the agreement with simulated results. The experimental measurements have been carried out using a practical implementation of the slit method. A Monte Carlo simulation model of scintillator screens, implemented with the toolkit Geant4, has been used to study the influence of the acquisition setup parameters and to compare with the experimental results. An algorithm of global stochastic optimization based on a localized random search method has been implemented to adjust the optical parameters (optical scattering and absorption coefficients). The algorithm has been tested for different X-ray tube voltages (40, 70 and 100 kV). A satisfactory convergence between the results simulated with the optimized model and the experimental measurements is obtained. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:719 / 727
页数:9
相关论文
共 50 条
  • [1] Monte Carlo study of spatial resolution of the scintillation camera
    ZHU Jie OUYANG XiaoPing CHEN Da Northwest Institute of Nuclear TechnologyXian China College of Material Science and TechnologyNanjing University of Aeronautics and AstronauticsNanjing China
    Science China(Technological Sciences), 2011, 54 (09) : 2373 - 2376
  • [2] Monte Carlo study of spatial resolution of the scintillation camera
    ZHU Jie 1
    2 College of Material Science and Technology
    Science China(Technological Sciences), 2011, (09) : 2373 - 2376
  • [3] Monte Carlo study of spatial resolution of the scintillation camera
    Zhu Jie
    Ouyang XiaoPing
    Chen Da
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (09) : 2373 - 2376
  • [4] Monte Carlo study of spatial resolution of the scintillation camera
    Jie Zhu
    XiaoPing Ouyang
    Da Chen
    Science China Technological Sciences, 2011, 54 : 2373 - 2376
  • [5] Modeling granular phosphor screens by Monte Carlo methods
    Liaparinos, Panagiotis F.
    Kandarakis, Ioannis S.
    Cavouras, Dionisis A.
    Delis, Harry B.
    Panayiotakis, George S.
    MEDICAL PHYSICS, 2006, 33 (12) : 4502 - 4514
  • [6] Monte Carlo modeling of scintillation detectors for continuous underground radon monitoring
    Haquin, Gustavo
    Zafrir, Hovav
    Ilzycer, Danielle
    Weisbrod, Noam
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2021, 237
  • [7] Towards Monte Carlo Modeling of the Optical Properties of Plastic Scintillation Detectors
    Simiele, E.
    DeWerd, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E867 - E867
  • [8] Monte Carlo modeling of heterogeneous scintillation flow-cell detectors
    Tan, H
    DeVol, TA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03): : 624 - 633
  • [9] Monte Carlo calculation of the spatial response (Modulated Transfer Function) of a scintillation flat panel and comparison with experimental results
    Juste, Belen
    Miro, Rafael
    Monasor, Paula
    Verdu, Gumersindo
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 181 - 185
  • [10] MONTE-CARLO CALCULATION OF THE RESPONSE OF NAI(TL) SCINTILLATION SPECTROMETERS
    BERGER, MJ
    DOGGETT, JA
    PHYSICAL REVIEW, 1955, 99 (02): : 663 - 663