Fracture Mechanism and Fracture Toughness at the Interface Between Cortical and Cancellous Bone

被引:7
|
作者
Shitole, Pankaj [1 ]
Gupta, Arpan [1 ]
Ghosh, Rajesh [1 ]
机构
[1] Indian Inst Technol Mandi, Sch Engn, Mandi 175005, Himachal Prades, India
关键词
fracture toughness; cortical and cancellous interface; corticellous bone; stress intensity factor; elastic-plastic fracture mechanics; J integral; COLLAGEN CROSS-LINKS; NONENZYMATIC GLYCATION; ORIENTATION; DEPENDENCE; STRENGTH;
D O I
10.1115/1.4044093
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The microstructure at the interface of cortical and cancellous bone is quite complicated. The fracture mechanisms at this location are necessary for understanding the comprehensive fracture of the whole bone. The goal of this study is to identify fracture toughness in terms of J integral and fracture mechanism at the interface between cortical and cancellous bone. For this purpose, single edge notch bend (SENB) specimens were prepared from bovine proximal femur according to ASTM-E399 standard. Bone samples were prepared such that half of the sample width consists of cortical bone and other half of the width was cancellous bone; this interfacial bone is referred as a corticellous bone. Elastic-plastic fracture mechanics was used to measure fracture toughness. The J integral (both elastic and plastic) was used to quantify the fracture toughness. The plastic part of J integral value (J(pl)) of corticellous specimen was 9310 J m(-2), and shown to be 27 times of the J integral of the elastic part (J(el)), 341 J m(-2). The total J integral of the corticellous bone was found to be 9651 J m(-2), which is close to two times of the cortical bone, 4731 J m(-2). This study observed that J integral of corticellous bone is higher than the cortical bone since more energy is required for plastic deformation of corticellous bone due to crack branches and slowdown at the interface between cortical and cancellous bone.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] FRACTURE TOUGHNESS OF COMPACT BONE
    BONFIELD, W
    DATTA, PK
    JOURNAL OF BIOMECHANICS, 1976, 9 (03) : 131 - &
  • [32] Fracture toughness of a corrugate interface between two dissimilar materials
    Pan, L.
    Cao, J. M.
    Yapici, U.
    Duan, L. X.
    Tao, J.
    Cai, L.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : 65 - 68
  • [33] Repair of a comminuted femoral fracture in a cat using cortical and cancellous bone grafting techniques
    Harasen, G
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 1997, 38 (09): : 574 - 575
  • [34] Combined deterioration of cancellous and cortical bone structure and the risk of vertebral fragility fracture.
    Qiu, S
    Palnitkar, S
    Rao, D
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (09) : S380 - S380
  • [35] In men with vertebral fracture cancellous bone is more affected than cortical bone but is not associated with increased bone breakdown
    Davie, MWJ
    Sharp, CA
    Davies, HL
    Evans, SF
    BONE, 2005, 36 : S376 - S376
  • [36] Diffuse damage accumulation in the fracture process zone of human cortical bone specimens and its influence on fracture toughness
    Parsamian, GP
    Norman, TL
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (09) : 779 - 783
  • [37] Diffuse damage accumulation in the fracture process zone of human cortical bone specimens and its influence on fracture toughness
    Gagik P. Parsamian
    Timothy L. Norman
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 779 - 783
  • [38] A novel Raman parameter correlates with the fracture toughness of human cortical bone.
    Unal, Mustafa
    Timur, Selin
    Uppuganti, Sasidhar
    Akkus, Ozan
    Nyman, Jeffry S.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2017, 32 : S304 - S304
  • [39] POLY METHYLMETHACRYLATE AS A FRACTURE ADHESIVE IN CANCELLOUS BONE
    WEBER, SC
    CHAPMAN, MW
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1982, 22 (07): : 644 - 644
  • [40] ORIENTATION AND AGE-RELATED DEPENDENCE OF THE FRACTURE-TOUGHNESS OF CORTICAL BONE
    BONFIELD, W
    BEHIRI, JC
    CULLEN, B
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 521 - 522