Flow Test to Predict Early Hypotony and Hypertensive Phase After Ahmed Glaucoma Valve (AGV) Surgical Implantation

被引:10
|
作者
Cheng, Jason [1 ]
Beltran-Agullo, Laura [2 ]
Buys, Yvonne M. [3 ]
Moss, Edward B. [3 ]
Gonzalez, Johanna [3 ]
Trope, Graham E. [3 ]
机构
[1] Khoo Tech Puat Hosp, Singapore, Singapore
[2] Inst Catala Retina, Barcelona, Spain
[3] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto Western Hosp, Toronto, ON, Canada
关键词
Ahmed glaucoma valve; glaucoma; surgery; hypotony; hypertensive phase; CLINICAL-EXPERIENCE; DRAINAGE DEVICES; CLOSING PRESSURE; MOLTENO IMPLANT; SINGLE-PLATE; IN-VITRO; BAERVELDT; POLYPROPYLENE; OUTCOMES;
D O I
10.1097/IJG.0000000000000318
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the validity of a preimplantation flow test to predict early hypotony [intraocular pressure (IOP) <= 5mm Hg on 2 consecutive visits and hypertensive phase (HP) (IOP > 21 mm Hg) after Ahmed Glaucoma Valve (AGV) implantation. Patients and Methods: Prospective interventional study on patients receiving an AGV. A preimplantation flow test using a gravity-driven reservoir and an open manometer was performed on all AGVs. Opening pressure (OP) and closing pressure (CP) were defined as the pressure at which fluid was seen to flow or stop flowing through the AGV, respectively. OP and CP were measured twice per AGV. Patients were followed for 12 weeks. Results: In total, 20 eyes from 19 patients were enrolled. At 12 weeks the mean IOP decreased from 29.2 +/- 9.1 to 16.8 +/- 5.2 mm Hg (P < 0.01). The mean AGV OP was 17.5 +/- 5.4 mm Hg and the mean CP was 6.7 +/- 2.3 mm Hg. Early (within 2 wk postoperative) HP occurred in 37% and hypotony in 16% of cases. An 18 mm Hg cutoff for the OP gave a sensitivity of 0.71, specificity of 0.83, positive predictive value of 0.71, and negative predictive value of 0.83 for predicting an early HP. A 7 mm Hg cutoff for the CP yielded a sensitivity of 1.0, specificity of 0.38, positive predictive value of 0.23, and negative predictive value of 1.0 for predicting hypotony. Conclusions: Preoperative OP and CP may predict early hypotony or HP and may be used as a guide as to which AGV valves to discard before implantation surgery.
引用
收藏
页码:493 / 496
页数:4
相关论文
共 50 条
  • [21] Surgical Outcomes of Additional Ahmed Glaucoma Valve Implantation in Refractory Glaucoma
    Ko, Sung Ju
    Hwang, Young Hoon
    Ahn, Sang Il
    Kim, Hwang Ki
    JOURNAL OF GLAUCOMA, 2016, 25 (06) : E620 - E624
  • [22] Ahmed glaucoma valve in vitrectomized eyes: An implantation technique to minimize early postoperative fluid-loss hypotony
    Arpa, Paolo
    Arpa, Cristina
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2759 - 2764
  • [23] Comparison of choroidal detachment with and without hypotony after Ahmed valve implantation
    Jin, Sang Wook
    Heo, Jung Woo
    Ahn, Hee Bae
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2025, 69 (01) : 110 - 115
  • [24] Retinal hemorrhages after Ahmed glaucoma valve implantation
    Hermann, C.
    Pillunat, K.
    Pillunat, L. E.
    OPHTHALMOLOGE, 2013, 110 (10): : 978 - 981
  • [25] Surgical outcomes of Ahmed gluacoma valve implantation in pseudoexfoliative glaucoma
    Kim, G. A.
    Ko, J.
    Bae, H.
    Hong, S.
    Kim, C. Y.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [26] Non-intraocular pressure-related revision surgeries after Ahmed glaucoma valve (AGV) implantation in refractory glaucoma
    Asli Kirmaci Kabakci
    Banu Solmaz
    Berna Basarir
    Burcu Kemer Atik
    Tekin Yasar
    International Ophthalmology, 2021, 41 : 3533 - 3538
  • [27] A scleral tunnel graft-free technique in Ahmed glaucoma valve (AGV) implantation
    Lim, Rongxuan
    Karydis, Andreas
    Taylor, Simon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [28] Non-intraocular pressure-related revision surgeries after Ahmed glaucoma valve (AGV) implantation in refractory glaucoma
    Kabakci, Asli Kirmaci
    Solmaz, Banu
    Basarir, Berna
    Atik, Burcu Kemer
    Yasar, Tekin
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (10) : 3533 - 3538
  • [29] Evaluation of early ocular discomfort after glaucoma surgery: trabeculectomy versus Ahmed glaucoma valve implantation
    Abe, Ricardo Y.
    Yamamoto, Douglas R.
    Souto, Fernanda Maria Silveira
    Vasconcellos, Jose Paulo Cabral
    Costa, Vital Paulino
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (03) : e20230033
  • [30] Two Cases of Malignant Glaucoma after Ahmed Valve Implantation
    Kim, Jae Hyun
    Chey, Ji Hyoung
    Lee, Chang Kyu
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (06): : 566 - 570