Defect Analysis on Optical Waveguide Arrays by Synchrotron Radiation Microtomography

被引:6
|
作者
Manescu, A. [1 ]
Di Gregorio, G. M. [2 ]
Girardin, E. [3 ]
Calbucci, V. [3 ]
Angeloni, G. [2 ]
Carta, P. [2 ]
Giuliani, A. [1 ]
Albertini, G. [3 ]
机构
[1] Univ Politecn Marche, Dipartimento DISCO, I-60131 Ancona, Italy
[2] SOMACIS SpA, R&D Dept, I-60022 Castelfidardo, Italy
[3] Univ Politecn Marche, Dipartimento FIMET, I-60131 Ancona, Italy
关键词
Computed microtomography (micro-CT); defect analysis; optical waveguides (OWGs); printed circuit boards (PCBs); synchrotron radiation;
D O I
10.1109/TDMR.2011.2168562
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, great attention has been devoted to the study and realization of polymeric optical waveguides embedded in printed circuit boards due to the increasing need of transferring large amounts of data at high speed within computer and telecommunication devices. Nonuniform microstructural defects that can be induced during the manufacturing process can dramatically influence the waveguide performance. The synchrotron radiation computed microtomography technique was used to obtain 3-D microstructural information, specifically to observe small defects, such as porosities, in a nondestructive way. Porosity level and pore size range were evaluated.
引用
收藏
页码:548 / 550
页数:3
相关论文
共 50 条
  • [1] Advances in synchrotron radiation microtomography
    Baruchel, Jos
    Buffiere, Jean-Yves
    Cloetens, Peter
    Di Michiel, Marco
    Ferrie, Emilie
    Ludwig, Wolfgang
    Maire, Eric
    Salvo, Luc
    SCRIPTA MATERIALIA, 2006, 55 (01) : 41 - 46
  • [2] A synchrotron radiation microtomography system for the analysis of trabecular bone samples
    Salomé, M
    Peyrin, F
    Cloetens, P
    Odet, C
    Laval-Jeantet, AM
    Baruchel, J
    Spanne, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2194 - 2204
  • [3] Tunneling escape in optical waveguide arrays with a boundary defect
    Longhi, Stefano
    PHYSICAL REVIEW E, 2006, 74 (02):
  • [4] Synchrotron radiation microtomography of the lung specimens
    Shimizu, F
    Ikezoe, J
    Ikura, H
    Ebara, H
    Nagareda, T
    Yagi, N
    Umetani, K
    Uesugi, K
    Okada, K
    Sugita, A
    Tanaka, M
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 196 - 204
  • [5] Synchrotron radiation microtomography applied to investigation of paper
    du Roscoat, SR
    Bloch, JF
    Thibault, X
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (10A) : A78 - A84
  • [6] Microtomography at a third generation synchrotron radiation facility
    Baruchel, J
    Boller, E
    Cloetens, P
    Ludwig, W
    Peyrin, F
    X-RAY TOMOGRAPHY IN MATERIAL SCIENCE, 2000, : 45 - 59
  • [7] Optical imaging of oral pathological tissue using optical coherence tomography and synchrotron radiation computed microtomography
    Canjau, Silvana
    Todea, Carmen
    Sinescu, Cosmin
    Negrutiu, Meda L.
    Duma, Virgil
    Manescu, Adrian
    Topala, Florin I.
    Podoleanu, Adrian Gh.
    HEAD AND NECK OPTICAL DIAGNOSTICS, 2013, 8805
  • [8] Observation of Defect-Free Surface Modes in Optical Waveguide Arrays
    Szameit, Alexander
    Garanovich, Ivan L.
    Heinrich, Matthias
    Sukhorukov, Andrey A.
    Dreisow, Felix
    Pertsch, Thomas
    Nolte, Stefan
    Tuennermann, Andreas
    Kivshar, Yuri S.
    PHYSICAL REVIEW LETTERS, 2008, 101 (20)
  • [9] High-energy microtomography using synchrotron radiation
    Beckmann, F
    Lippmann, T
    Bonse, U
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 225 - 230
  • [10] COMPUTERIZED MICROTOMOGRAPHY USING SYNCHROTRON RADIATION FROM THE NSLS
    SPANNE, P
    RIVERS, ML
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 : 1063 - 1067