Quantification of airway thickness changes in smoke-inhalation injury using in-vivo 3-D endoscopic frequency-domain optical coherence tomography

被引:23
|
作者
Lee, Sang-Won [1 ]
Heidari, Andrew E. [2 ]
Yoon, David [1 ]
Mukai, David [1 ]
Ramalingam, Tirunelveli [2 ]
Mahon, Sari [1 ]
Yin, Jiechen [3 ]
Jing, Joseph [3 ]
Liu, Gangjun [1 ]
Chen, Zhongping [1 ,3 ]
Brenner, Matthew [1 ,4 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[2] OCT Med Imaging Inc, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[4] UC Irvine Med Ctr, Pumonary & Crit Care Div, Orange, CA 92868 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 02期
基金
新加坡国家研究基金会;
关键词
NITRIC-OXIDE; BURN; BRONCHOSCOPY; INFLAMMATION; DIAGNOSIS; SHEEP;
D O I
10.1364/BOE.2.000243
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Smoke inhalation injury is frequently accompanied by cyanide poisoning that may result in substantial morbidity and mortality, and methods are needed to quantitatively determine extent of airway injury. We utilized a 3-D endoscopic frequency-domain optical coherence tomography (FD-OCT) constructed with a swept-source laser to investigate morphological airway changes following smoke and cyanide exposure in rabbits. The thickness of the mucosal area between the epithelium and cartilage in the airway was measured and quantified. 3-D endoscopic FD-OCT was able to detect significant increases in the thickness of the tracheal walls of the rabbit beginning almost immediately after smoke inhalation injuries which were similar to those with combined smoke and cyanide poisoning. (C) 2011 Optical Society of America
引用
下载
收藏
页码:243 / 254
页数:12
相关论文
共 33 条
  • [1] In Vivo Tracheal Compliance Changes In An Animal Model Of Smoke Inhalation Using Optical Coherence Tomography
    Robertson, C.
    Ikemura, K.
    Chun, E.
    Jing, J.
    Mukai, D.
    Mahon, S.
    Chen, Z.
    Brenner, M.
    George, S. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [2] In vivo optical coherence tomography detection of differences in regional large airway smoke inhalation induced injury in a rabbit model
    Brenner, Matthew
    Kreuter, Kelly
    Ju, Johnny
    Mahon, Sari
    Seng, Lillian
    Mukai, David
    Burney, Tanya
    Guo, Shuguang
    Su, Jianping
    Tran, Andrew
    Batchinsky, Andriy
    Cancio, Leopoldo C.
    Narula, Navneet
    Chen, Zhongping
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (03)
  • [3] Point-of-care endoscopic optical coherence tomography detects changes in mucosal thickness in ARDS due to smoke inhalation and burns
    Choi, Jae Hyek
    Chou, Li-Dek
    Roberts, Teryn R.
    Beely, Brendan M.
    Wendorff, Daniel S.
    Espinoza, Mark D.
    Sieck, Kyle
    Dixon, Alexander T.
    Burmeister, David
    Jordan, Bryan S.
    Brenner, Matthew
    Chen, Zhongping
    Necsoiu, Corina
    Cancio, Leopoldo C.
    Batchinsky, Andriy, I
    BURNS, 2019, 45 (03) : 589 - 597
  • [4] In vivo early detection of smoke-induced airway injury using 3-dimensional swept source optical coherence tomography
    Yin, Jiechen
    Liu, Gangjun
    Zhang, Jun
    Yu, Linfeng
    Mahon, Sari
    Mukai, David
    Brenner, Matthew
    Chen, Zhongping
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [5] Measurement of Local Retinal Ganglion Cell Layer Thickness in Patients With Glaucoma Using Frequency-Domain Optical Coherence Tomography
    Wang, Min
    Hood, Donald C.
    Cho, Jung-Suk
    Ghadiali, Quraish
    De Moraes, Gustavo V.
    Zhang, Xian
    Ritch, Robert
    Liebmann, Jeffrey M.
    ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (07) : 875 - 881
  • [6] Evaluation of morphological changes in degenerative cartilage using 3-D Optical Coherence Tomography
    Youn, Jong-In
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2008, 12 (02) : 98 - 102
  • [7] In vivo Retinal Thickness Quantification in brn3b-/- Mice Using Optical Coherence Tomography Segmentation
    Camp, A. S.
    Ruggeri, M.
    Munguba, G. C.
    Bhattacharya, S. K.
    Lee, R. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] 3D imaging of tomato seeds using frequency domain optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY IV, 2012, 8369
  • [9] Jailed side branches: fate of unapposed struts studied with 3D frequency-domain optical coherence tomography
    Foin, Nicolas
    Viceconte, Nicola
    Chan, Pak H.
    Lindsay, Alistair C.
    Krams, Rob
    Di Mario, Carlo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2011, 12 (08) : 581 - 582
  • [10] Measurement of Thickness and Refractive Index of Optical Samples Simultaneously Using Full-Range One-Shot Frequency-Domain Optical Coherence Tomography
    Cheng, Hsu-Chih
    Huang, Chia-Tsai
    FIBER AND INTEGRATED OPTICS, 2015, 34 (03) : 171 - 182