Noninvasive Blood Pressure Analysis using Empirical Mode Decomposition (EMD) - Based Oscillometric Method

被引:3
|
作者
Hsiao, Fu-Jung [1 ]
Hung, Chen-Chuan [1 ]
机构
[1] Ind Technol Res Inst, Ctr Measurement Stand, Hsinchu, Taiwan
来源
2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7 | 2010年
关键词
noninvasive blood pressure measurement; empirical mode decomposition; oscillometric method;
D O I
10.1109/BMEI.2010.5639803
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study proposes a new method to extract oscillometric pulses for noninvasive blood pressure measurement using empirical mode decomposition, based on the oscillometric method. The mean and standard deviation of the present method in systolic and diastolic pressure are 1.6 and 5.2, and 0.7 and 5.2, respectively, which not only passes the AAMI (Association for the Advancement of Medical Instrumentation) and EN (European Norm) blood pressure measurement criteria, but also performs more accurate measurements than commercial noninvasive blood pressure measurement devices.
引用
收藏
页码:973 / 977
页数:5
相关论文
共 50 条
  • [21] Dynamic Body Postures Recognition with WiFi Based on Empirical Mode Decomposition (EMD)
    Ye, Min
    Jiang, Ting
    2017 17TH INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES (ISCIT), 2017,
  • [22] An Adaptive ECG Noise Removal Process Based on Empirical Mode Decomposition (EMD)
    Hussein, Ahmed F.
    Mohammed, Warda R.
    Jaber, Mustafa Musa
    Khalaf, Osamah Ibrahim
    CONTRAST MEDIA & MOLECULAR IMAGING, 2022, 2022
  • [23] Autoregressive Modeling Based Empirical Mode Decomposition (EMD) for Epileptic Seizures Detection Using EEG Signals
    Rafik, Djemili
    Larbi, Boubchir
    TRAITEMENT DU SIGNAL, 2019, 36 (03) : 273 - 279
  • [24] A Diffusion-Based Two-Dimensional Empirical Mode Decomposition (EMD) Algorithm for Image Analysis
    Wang, Heming
    Mann, Richard
    Vrscay, Edward R.
    IMAGE ANALYSIS AND RECOGNITION (ICIAR 2018), 2018, 10882 : 295 - 305
  • [25] Underwater Ambient Noise Analysis Using Empirical Mode Decomposition Method
    Isabekov, Altynbek
    Baykut, Sueleyman
    Akgul, Tayfun
    2009 IEEE 17TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, VOLS 1 AND 2, 2009, : 862 - 865
  • [26] A New Algorithm of Blood Pressure Measurement Based on Oscillometric Method
    Luo, Cong
    Li, Tingyu
    Quan, Xiaoli
    Gu, Liangling
    Zhao, Mingfu
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1710 - +
  • [27] A new Arterial Blood Pressure Holter based on the oscillometric method
    Vallascas, Rinaldo
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 224 - 228
  • [28] A correlation based bullet identification method using empirical mode decomposition
    Bigdeli, Saeed
    Danandeh, Hamed
    Moghaddam, Mohsen Ebrahimi
    FORENSIC SCIENCE INTERNATIONAL, 2017, 278 : 351 - 360
  • [29] A Method of Analysis Breaking Waves Shape Based on Empirical Mode Decomposition
    Chen Zezong
    Yi Sheng
    Zhao Chen
    OCEANS 2016 - SHANGHAI, 2016,
  • [30] Image Analysis Based on An Improved Bidimensional Empirical Mode Decomposition Method
    Zhang, Dan
    Pan, Jianjia
    Tang, Yuan Yan
    PROCEEDINGS OF THE 2010 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, 2010, : 144 - 149