Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs

被引:70
|
作者
Bodey, AR [1 ]
Michell, AR [1 ]
Bovee, KC [1 ]
Buranakurl, C [1 ]
Garg, T [1 ]
机构
[1] UNIV PENN,SCH VET MED,PHILADELPHIA,PA 19104
关键词
D O I
10.1016/S0034-5288(96)90104-6
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Oscillometric measurements of arterial blood pressure were compared with direct measurements made on seven dogs fitted with catheters. Tail and limb cuff sites were used while the dogs were gently restrained either standing or in lateral recumbency. The accuracy of the readings for the various cuff sites was compared with the direct (gold standard) readings. The accuracy of the indirect readings was improved by using mean values from a series of readings rather than individual values and when the dogs were in lateral recumbency rather than standing. The differences between the direct and indirect values were greatest with high pressures,;and with systolic rather than diastolic values. In standing dogs, the proximal forelimb readings (when obtainable) correlated most closely with the direct readings. The tail cuff readings correlated significantly with the direct readings, though less closely. The tail cuff readings were the most easily recorded in the standing dogs. In the laterally recumbent dogs, the readings from all the cuff sites correlated closely with the direct values except for diastolic readings from the distal hindlimb.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [41] Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure
    Kiers, H. D.
    Hofstra, J. M.
    Wetzels, J. F. M.
    [J]. NETHERLANDS JOURNAL OF MEDICINE, 2008, 66 (11): : 474 - 479
  • [42] Comparison of indirect and direct blood pressure measurements in baboons during ketamine anaesthesia
    Yeung, Kristen R.
    Lind, Joanne M.
    Heffernan, Scott J.
    Sunderland, Neroli
    Hennessy, Annemarie
    Makris, Angela
    [J]. JOURNAL OF MEDICAL PRIMATOLOGY, 2014, 43 (04) : 217 - 224
  • [43] Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting
    Hsiang, Tsai-Yuan
    Lien, Yu-Hsin
    Huang, Hui-Pi
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 2008, 70 (05): : 449 - 453
  • [44] Blood Pressure Measurements in Dogs and Horses Using the Oscillometric Technique: Personal Observations
    F. Porciello
    F. Birettoni
    M.B. Conti
    C. Marinetti
    M.T. Antognoni
    G. Fruganti
    [J]. Veterinary Research Communications, 2004, 28 : 367 - 369
  • [45] Blood pressure measurements in dogs and horses using the oscillometric technique: Personal observations
    Porciello, F
    Birettoni, F
    Conti, MB
    Marinetti, C
    Antognoni, MT
    Fruganti, G
    [J]. VETERINARY RESEARCH COMMUNICATIONS, 2004, 28 (01) : 367 - 369
  • [46] DIRECT ARTERIAL BLOOD-PRESSURE MEASUREMENTS
    GOYETTE, RE
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1981, 246 (16): : 1771 - 1771
  • [47] COMPARISON OF DIRECT AND INDIRECT METHODS OF MEASURING ARTERIAL BLOOD-PRESSURE .2.
    BRUNER, JMR
    KRENIS, LJ
    KUNSMAN, JM
    SHERMAN, AP
    [J]. MEDICAL INSTRUMENTATION, 1981, 15 (02): : 97 - 101
  • [48] COMPARISON OF DIRECT AND INDIRECT METHODS OF MEASURING ARTERIAL BLOOD-PRESSURE .3.
    BRUNER, JMR
    KRENIS, LJ
    KUNSMAN, JM
    SHERMAN, AP
    [J]. MEDICAL INSTRUMENTATION, 1981, 15 (03): : 182 - 188
  • [49] Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs
    Jimenez-Ballen, Valentina
    Vargas-Pinto, Pedro
    [J]. REVISTA DE INVESTIGACIONES VETERINARIAS DEL PERU, 2018, 29 (04): : 1156 - 1160
  • [50] COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS)
    Cassia, Emma V. Sant
    Boswood, Adrian
    Tordiffe, Adrian S. W.
    [J]. JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2015, 46 (03) : 506 - 516