Reproducibility and reliability of hypoglycaemic episodes recorded with Continuous Glucose Monitoring System (CGMS) in daily life

被引:32
|
作者
Hoi-Hansen, T [1 ]
Pedersen-Bjergaard, U [1 ]
Thorsteinsson, B [1 ]
机构
[1] Hillerod Hosp, Dept Internal Med F, DK-3400 Hillerod, Denmark
关键词
continuous glucose monitoring system; hypoglycaemia; self-monitored blood glucose; Type; 1; diabetes;
D O I
10.1111/j.1464-5491.2005.01552.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Continuous glucose monitoring may reveal episodes of unrecognized hypoglycaemia. We evaluated reproducibility and reliability of hypoglycaemic episodes recorded in daily life by the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS). Methods Twenty-nine adult patients with Type 1 diabetes underwent 6 days of continuous subcutaneous glucose monitoring, applying one CGMS on each side of the abdomen. Blood glucose was measured by HemoCue B-Glucose Analyzers six times daily and two different 4-point calibration sets were generated (set A and B). Using these calibration sets, CGMS raw data were recalibrated generating four different CGMS data sets [left-A (left side of abdomen, calibration set A), left-B, right-A and right-B]. Agreement between CGMS data sets was evaluated during hypoglycaemic events, comparing CGMS readings = 2.2 mmol/l with nadir values from corresponding CGMS data sets. CGMS readings were also compared with independent self-monitored blood glucose (SMBG) values. Results With hypoglycaemia (CGMS readings = 2.2 mmol/l) in calibration set left-A, values below 3.5 mmol/l were present in 99% (95% CI: 95-100%) of samples in left-B, 91% (95% CI: 84-96%) of samples in right-A, and 90% (95% CI: 83-95%) of samples in right B. In 84% of these episodes (95% CI: 59-96%) independent SMBG values were below 3.5 mmol/l. Difference in duration was observed with a median difference of 20 min; (left-A vs. right-B). Conclusion Hypoglycaemic episodes recorded by CGMS are reproducible and agreement with independent SMBG values is acceptable for retrospective recording of hypoglycaemic events with CGMS.
引用
收藏
页码:858 / 862
页数:5
相关论文
共 50 条
  • [21] The Utility and Safety of a Continuous Glucose Monitoring System (CGMS) in Asphyxiated Neonates during Therapeutic Hypothermia
    Giordano, Lucia
    Perri, Alessandro
    Tiberi, Eloisa
    Sbordone, Annamaria
    Patti, Maria Letizia
    D'Andrea, Vito
    Vento, Giovanni
    DIAGNOSTICS, 2023, 13 (18)
  • [22] Functionality of the MiniMed continuous glucose monitoring system (CGMS) in young children with type 1 diabetes
    Gandrud, LM
    Block, JM
    Kunselman, BL
    Wilson, DM
    Buckingham, BA
    DIABETES, 2004, 53 : A462 - A462
  • [23] SATISFACTION WITH CLINICAL USE OF CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS) IN JAPANESE PEOPLE WITH DIABETES AND WITH NORMAL GLUCOSE TOLERANCE
    Imai, S.
    Matsuda, M.
    Kajiyama, S.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 1216 - 1216
  • [24] Evaluation of metabolic control in gestational diabetic women (GDM) by the continuous glucose monitoring system (CGMS)
    Cypryk, K
    Szymczak, W
    Szosland, K
    Sobczak, M
    Zawodniak-Szalapska, M
    Lewinski, A
    DIABETOLOGIA, 2004, 47 : A346 - A347
  • [25] Pioglitazone and insulin: Effects on tight glycaemic control assessed by the continuous glucose monitoring system (CGMS)
    Jung, WG
    Jung, SR
    DIABETES, 2004, 53 : A156 - A156
  • [26] Nocturnal hypoglycaemia in diabetic children: the role of continuous glucose monitoring (cgms)
    Bachmann, S.
    Ritschard, V.
    Hess, M.
    Jockers, K.
    Zumsteg, U.
    SWISS MEDICAL WEEKLY, 2014, 144 : 16S - 16S
  • [27] EVALUATION OF THE HYPOGLYCAEMIA SYMPTOM RATING QUESTIONNAIRE (HYPOSRQ) AND ITS RELATIONSHIP WITH HYPOGLYCAEMIC EPISODES MEASURED USING CONTINUOUS GLUCOSE MONITORING
    Taylor, M. D.
    Han, T. S.
    Ward, H.
    McBride, J.
    Yap, I.
    Bradley, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A23 - A24
  • [28] The Somogyi phenomenon revisited using continuous glucose monitoring in daily life
    T. Høi-Hansen
    U. Pedersen-Bjergaard
    B. Thorsteinsson
    Diabetologia, 2005, 48 : 2437 - 2438
  • [29] The Somogyi phenomenon revisited using continuous glucose monitoring in daily life
    Hoi-Hansen, T
    Pedersen-Bjergaard, U
    Thorsteinsson, B
    DIABETOLOGIA, 2005, 48 (11) : 2437 - 2438
  • [30] Performance of the continuous glucose monitoring system CGMS® during development of ketosis in patients on insulin pump therapy
    Pfützner, J
    Forst, T
    Butzer, R
    Forst, S
    Weber, M
    Pfützner, A
    Pfützner, A
    DIABETES, 2005, 54 : A98 - A98