Reproducibility and reliability of hypoglycaemic episodes recorded with Continuous Glucose Monitoring System (CGMS) in daily life

被引:32
|
作者
Hoi-Hansen, T [1 ]
Pedersen-Bjergaard, U [1 ]
Thorsteinsson, B [1 ]
机构
[1] Hillerod Hosp, Dept Internal Med F, DK-3400 Hillerod, Denmark
关键词
continuous glucose monitoring system; hypoglycaemia; self-monitored blood glucose; Type; 1; diabetes;
D O I
10.1111/j.1464-5491.2005.01552.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Continuous glucose monitoring may reveal episodes of unrecognized hypoglycaemia. We evaluated reproducibility and reliability of hypoglycaemic episodes recorded in daily life by the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS). Methods Twenty-nine adult patients with Type 1 diabetes underwent 6 days of continuous subcutaneous glucose monitoring, applying one CGMS on each side of the abdomen. Blood glucose was measured by HemoCue B-Glucose Analyzers six times daily and two different 4-point calibration sets were generated (set A and B). Using these calibration sets, CGMS raw data were recalibrated generating four different CGMS data sets [left-A (left side of abdomen, calibration set A), left-B, right-A and right-B]. Agreement between CGMS data sets was evaluated during hypoglycaemic events, comparing CGMS readings = 2.2 mmol/l with nadir values from corresponding CGMS data sets. CGMS readings were also compared with independent self-monitored blood glucose (SMBG) values. Results With hypoglycaemia (CGMS readings = 2.2 mmol/l) in calibration set left-A, values below 3.5 mmol/l were present in 99% (95% CI: 95-100%) of samples in left-B, 91% (95% CI: 84-96%) of samples in right-A, and 90% (95% CI: 83-95%) of samples in right B. In 84% of these episodes (95% CI: 59-96%) independent SMBG values were below 3.5 mmol/l. Difference in duration was observed with a median difference of 20 min; (left-A vs. right-B). Conclusion Hypoglycaemic episodes recorded by CGMS are reproducible and agreement with independent SMBG values is acceptable for retrospective recording of hypoglycaemic events with CGMS.
引用
收藏
页码:858 / 862
页数:5
相关论文
共 50 条
  • [1] Continuous glucose monitoring system (CGMS) in hypoglycemia
    Harwood, K
    Aponte, L
    Rincon, M
    DiMartino-Nardi, J
    Muzumdar, R
    Saenger, P
    PEDIATRIC RESEARCH, 2004, 55 (04) : 149A - 149A
  • [2] The MiniMed Continuous Glucose Monitoring System (CGMS)
    Mastrototaro, J
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 1999, 12 : 751 - 758
  • [3] ACCURACY AND RELIABILITY OF A SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS) IN CRITICALLY ILL PATIENTS
    Brunner, R.
    Kitzberger, R.
    Miehsler, W.
    Herkner, H.
    Madl, C.
    Holzinger, U.
    INTENSIVE CARE MEDICINE, 2010, 36 : S171 - S171
  • [4] CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS) IN KIDNEY TRANSPLANTED CHILDREN
    Pasti, Krisztina
    Szabo, Attila J.
    Prokai, Agnes
    Peko, Nora
    Sallay, Peter
    Reusz, Gyoergy
    Rusai, Krisztina
    PEDIATRIC TRANSPLANTATION, 2013, 17 : 94 - 94
  • [5] Nocturnal hypoglycemia (NH) detected with the continuous glucose monitoring system (CGMS)
    Kaufman, FR
    Halvorson, M
    Carpenter, S
    Neinstein, A
    Fisher, LK
    Devoe, DJ
    Pitukcheewanont, P
    Chang, N
    DIABETES, 2001, 50 : A448 - A449
  • [6] Experience with the Continuous Glucose Monitoring System (CGMS®) in critically ill patients
    Goldberg, P
    Inzucchi, S
    Siegel, M
    Halickman, J
    Cooper, D
    Sherwin, R
    DIABETES, 2003, 52 : A94 - A94
  • [7] Continuous glucose monitoring system (CGMS) in kidney-transplanted children
    Pasti, Krisztina
    Szabo, Attila J.
    Prokai, Agnes
    Meszaros, Krisztina
    Peko, Nora
    Solyom, Reka
    Sallay, Peter
    Reusz, Gyoergy
    Rusai, Krisztina
    PEDIATRIC TRANSPLANTATION, 2013, 17 (05) : 454 - 460
  • [8] Accuracy of a Continuous Glucose Monitoring System (CGMS): Still Room for Improvement
    Heckermann, Sascha
    Nosek, Leszek
    Zijlstra, Eric
    Heise, Tim
    DIABETES, 2010, 59 : A131 - A132
  • [9] Accuracy of a continuous glucose monitoring system (CGMS): still room for improvement
    Heckermann, S.
    Nosek, L.
    Zijlstra, E.
    Heise, T.
    DIABETOLOGIA, 2010, 53 : S26 - S27
  • [10] Characteristics of glucose metabolism indexes and continuous glucose monitoring system (CGMS) in patients with insulinoma
    Gu, Weijun
    Liu, Yixin
    Liu, Hongyan
    Yang, Guoqing
    Guo, Qinghua
    Du, Jin
    Jin, Nan
    Zang, Li
    Lv, Zhaohui
    Ba, Jianming
    Mu, Yiming
    Dou, Jingtao
    DIABETOLOGY & METABOLIC SYNDROME, 2017, 9