Determination of multiple chelator complexes in aqueous matrices using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry

被引:7
|
作者
Miah, Sohag [1 ]
Rahman, Ismail M. M. [2 ]
Takemura, Masashi [1 ]
Fukiage, Shohei [1 ]
Mashio, Asami S. [3 ]
Maki, Teruya [3 ]
Hasegawa, Hiroshi [3 ]
机构
[1] Kanazawa Univ, Grad Sch Nat Sci & Technol, Kanazawa, Ishikawa 9201192, Japan
[2] Fukushima Univ, Inst Environm Radioact, 1 Kanayagawa, Fukushima, Fukushima 9601296, Japan
[3] Kanazawa Univ, Inst Sci & Engn, Kanazawa, Ishikawa 9201192, Japan
基金
日本学术振兴会;
关键词
Metal-chelator complex; Simultaneous determination; Biodegradable chelator; Natural aqueous matrices; HILIC; UPLC-Q-TOF-MS; HYDROPHILIC INTERACTION CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TOF-MS METHOD; ETHYLENEDIAMINETETRAACETIC ACID; ION CHROMATOGRAPHY; CHARGED IONS; HEAVY-METALS; PEAK SHAPE; SPECIATION; WATER;
D O I
10.1016/j.talanta.2018.10.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of aminopolycarboxylate chelators in environmental samples has remained an analytical challenge due to the structural similarities of these species and their minute concentrations in such matrices. Herein, we report a fast and sensitive technique for the determination of multiple chelator complexes in an aqueous matrix using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry (UPLC-Q-TOF-MS). Eight chelators, including non-biodegradable (EDTA, EDTAOH, GEDTA, DPTAOH and DTPA) and biodegradable (EDDS, GLDA, and MGDA) variants were examined after complexation with Cu-II. The detection of these species using reverse-phase chromatography was compared with that achieved with hydrophilic interaction chromatography based on the corresponding peak resolution and retention time. The effect of varying the composition and pH of the mobile phase on the corresponding peak profiles and intensities for the chelator complexes was also evaluated. The Cu-II-derivatives of the chelators were individually detected under the optimized operating conditions. Relative to high-performance liquid chromatography equipped with a photodiode array detector, the developed UPLC-Q-TOF-MS technique provides rapid determination of chelator complexes in aqueous matrices with high sensitivity and superior peak resolution. The limit of detection ranged from 1.7-36 nmol L-1 and the limit of quantification ranged from 5.7-120 nmol L-1 for the eight chelator complexes in solution. The coefficients of determination (R-2) were 0.962-0.999 for the chelators with an average relative uncertainty of 2.2%. The method was validated using a simulated mixed matrix and river water by standard addition (recovery: 83-100%).
引用
收藏
页码:980 / 990
页数:11
相关论文
共 50 条
  • [1] A technique for the speciation analysis of metal-chelator complexes in aqueous matrices using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry
    Miah, Sohag
    Fukiage, Shohei
    Begum, Zinnat A.
    Murakami, Takaya
    Mashio, Asami S.
    Rahman, Ismail M. M.
    Hasegawa, Hiroshi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2020, 1630
  • [2] In vivo metabolite identification of acotiamide in rats using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry
    Patel, Prinesh N.
    Kalariya, Pradipbhai D.
    Thummar, Mohit
    Gananadhamu, S.
    Srinivas, R.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (07)
  • [3] Sensitive determination of picrotoxin by liquid chromatography-quadrupole time-of-flight mass spectrometry
    Ogawa, Tadashi
    Tada, Miho
    Hattori, Hideki
    Shiraishi, Yosuke
    Suzuki, Takayoshi
    Iwai, Masae
    Kusano, Maiko
    Zaitsu, Kei
    Ishii, Akira
    Seno, Hiroshi
    [J]. LEGAL MEDICINE, 2016, 20 : 8 - 11
  • [4] In vitro and in vivo metabolism of ochratoxin A: a comparative study using ultra-performance liquid chromatography-quadrupole/time-of-flight hybrid mass spectrometry
    Yang, Shupeng
    Zhang, Huiyan
    De Saeger, Sarah
    De Boevre, Marthe
    Sun, Feifei
    Zhang, Suxia
    Cao, Xingyuan
    Wang, Zhanhui
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (13) : 3579 - 3589
  • [5] A novel method to analyze hepatotoxic components in Polygonum multiflorum using ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry
    Lin, Longfei
    Lin, Hongmei
    Zhang, Miao
    Ni, Boran
    Yin, Xingbin
    Qu, Changhai
    Ni, Jian
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2015, 299 : 249 - 259
  • [6] In vitro and in vivo metabolism of ochratoxin A: a comparative study using ultra-performance liquid chromatography-quadrupole/time-of-flight hybrid mass spectrometry
    Shupeng Yang
    Huiyan Zhang
    Sarah De Saeger
    Marthe De Boevre
    Feifei Sun
    Suxia Zhang
    Xingyuan Cao
    Zhanhui Wang
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 3579 - 3589
  • [7] Determination of heterocyclic amines by liquid chromatography-quadrupole time-of-flight mass spectrometry
    Barceló-Barrachina, E
    Moyano, E
    Galceran, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) : 409 - 418
  • [8] Ultra-performance liquid chromatography coupled to quadrupole-orthogonal time-of-flight mass spectrometry
    Plumb, R
    Castro-Perez, J
    Granger, J
    Beattie, I
    Joncour, K
    Wright, A
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) : 2331 - 2337
  • [9] Determination of furosine in liquid milk by high performance liquid chromatography-quadrupole time-of-flight mass spectrometry
    Yao Guihong
    Ling Yun
    Zhang Yujia
    Xing Shige
    Yao Meiyi
    Guo Wei
    Zhang Feng
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (11) : 1038 - 1043
  • [10] Ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry analysis of the impact of processing on toxic components of Kansui Radix
    Xin Shu
    Xi-Wen Jiang
    Brian Chi-Yan Cheng
    Shuang-Cheng Ma
    Guang-Ying Chen
    Zhi-Ling Yu
    [J]. BMC Complementary and Alternative Medicine, 16