Noninvasive detection of coronary allograft vasculopathy by myocardial contrast echocardiography

被引:15
|
作者
Rodrigues, ACT [1 ]
Bacal, F [1 ]
Medeiros, CC [1 ]
Bocchi, E [1 ]
Sbano, J [1 ]
Morhy, SS [1 ]
Mathias, W [1 ]
Andrade, JL [1 ]
机构
[1] Univ Sao Paulo, Hosp Clin, Fac Med, Inst Heart,InCor, Sao Paulo, Brazil
关键词
D O I
10.1016/j.echo.2004.09.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Noninvasive detection of coronary allograft vasculopathy is still challenging. To determine the accuracy of myocardial contrast echocardiography (MCE) in detecting coronary allograft vasculopathy after heart transplantation, we studied 35 asymptomatic patients (30 men, aged 46 +/- 12.7 years) with normal left ventricular function. Methods: Patients underwent MCE with continuous contrast (perfluorocarbon-exposed sonicated dextrose albumin) administration. Images were obtained at baseline and during peak dobutamine (up to 40 mg/kg/min) with intermittent harmonic imaging. Areas failing to increase contrast enhancement during peak stress were regarded as abnormal. Coronary artery obstructions greater than 50% at angiography were considered significant. Results. Seven out of 10 patients with coronary artery disease had a positive MCE and one patient with a positive MCE had no angiographically detected disease (sensitivity = 70%, specificity = 96%, accuracy = 88.6%). Agreement between the vascular territory and perfusion defects was good for the left anterior descending coronary artery (kappa = 0.56), but not for other arteries. Although 5 patients had multivessel disease, multiple perfusion defects were detected in only one patient. Conclusion: MCE showed good accuracy in detecting the presence of coronary allograft vasculopathy after heart transplantation; however, it failed to identify the extent of the disease.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 50 条
  • [31] Reliable noninvasive diagnosis of coronary allograft vasculopathy: is it still wishful thinking? - Reply
    Caus, Thierry
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (05) : 863 - 864
  • [32] Noninvasive assessment of myocardial perfusion in mice: A contrast echocardiography study
    Scherrer-Crosbie, M
    Steudel, W
    Hunziker, PR
    Liel-Cohen, N
    Zapol, WM
    Picard, MH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 438A - 439A
  • [33] Noninvasive assessment of coronary flow reserve by intravenous myocardial contrast echocardiography: comparison with magnetic resonance imaging
    Jung, PH
    Borgmann, T
    Strotmann, J
    Wacker, C
    Dueren, C
    Fidler, F
    Bauer, W
    Angermann, CE
    EUROPEAN HEART JOURNAL, 2002, 23 : 544 - 544
  • [34] Quantitative myocardial blush grade for the detection of cardiac allograft vasculopathy
    Korosoglou, Grigorios
    Riedle, Nina
    Erbacher, Markus
    Dengler, Thomas J.
    Zugck, Christian
    Rottbauer, Wolfgang
    Hardt, Stefan
    Bekeredjian, Raffi
    Kristen, Arnt
    Giannitsis, Evangelos
    Osman, Neal F.
    Dickhaus, Hartmut
    Katus, Hugo A.
    AMERICAN HEART JOURNAL, 2010, 159 (04) : 643 - U176
  • [35] Dobutamine stress echocardiography for noninvasive diagnosis of cardiac allograft vasculopathy: A comparison with angiography and intravascular ultrasound
    Spees, CH
    Mudra, H
    Schnaack, SD
    Klauss, V
    Reichle, FM
    Uberfuhr, P
    Theisen, K
    Angermann, CE
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (02): : 168 - 174
  • [36] Accuracy of quantitative myocardial stress perfusion imaging in the detection of coronary allograft vasculopathy after heart transplant
    Alessi, A
    Sara, R
    Cavenaghi, G
    Devoto, E
    Turazza, F
    Frigerio, M
    Parodi, O
    EUROPEAN HEART JOURNAL, 2002, 23 : 432 - 432
  • [37] NONINVASIVE SCREENING FOR CARDIAC ALLOGRAFT VASCULOPATHY BY SERIAL DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN COMPARISON WITH INTRAVASCULAR ULTRASOUND
    SPES, CH
    MUDRA, H
    SCHNAACK, SD
    KLAUSS, V
    REICHLE, FM
    UBERFUHR, P
    ANGERMANN, CE
    THEISEN, K
    CIRCULATION, 1995, 92 (08) : 420 - 420
  • [38] Diagnostic and prognostic value of serial dobutamine stress echocardiography for noninvasive assessment of cardiac allograft vasculopathy -: A comparison with coronary angiography and intravascular ultrasound
    Spes, CH
    Klauss, V
    Mudra, H
    Schnaack, SD
    Tammen, AR
    Rieber, J
    Siebert, U
    Henneke, KH
    Überfuhr, P
    Reichart, B
    Theisen, K
    Angermann, CE
    CIRCULATION, 1999, 100 (05) : 509 - 515
  • [39] CONTRAST ECHOCARDIOGRAPHY FOR THE DETECTION OF MYOCARDIAL PERFUSION ABNORMALITIES
    ARMSTRONG, WF
    KINNEY, EL
    MUELLER, TM
    RASOR, J
    TICKNER, EG
    DILLON, JC
    FEIGENBAUM, H
    CIRCULATION, 1981, 64 (04) : 204 - 204
  • [40] Early detection of coronary microvascular endothelial dysfunction using intravenous myocardial contrast echocardiography
    Huang, XB
    Liu, YL
    Wu, PS
    Zha, DG
    Luo, Y
    Chen, XL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 385A - 385A