Microbiological and Toxicological Hazards in Sewage Treatment Plant Bioaerosol and Dust

被引:18
|
作者
Szulc, Justyna [1 ]
Okrasa, Malgorzata [2 ]
Majchrzycka, Katarzyna [2 ]
Sulyok, Michael
Nowak, Adriana [1 ]
Ruman, Tomasz [3 ]
Niziol, Joanna [3 ]
Szponar, Bogumila [4 ]
Gutarowska, Beata [1 ]
机构
[1] Lodz Univ Technol, Dept Environm Biotechnol, PL-90530 Lodz, Poland
[2] Natl Res Inst, Cent Inst Labour Protect, Dept Personal Protect Equipment, PL-90133 Lodz, Poland
[3] Rzeszow Univ Technol, Fac Chem, PL-35959 Rzeszow, Poland
[4] Polish Acad Sci, Inst Immunol & Expt Therapy, PL-53113 Wroclaw, Poland
关键词
bioaerosol; harmful biological agents; metagenome analysis; mycotoxins; cytotoxicity; sewage treatment plant; WATER TREATMENT-PLANT; WASTE-WATER; DISINFECTANT RESISTANCE; EXPOSURE; ENDOTOXIN; INDOOR; AIR; NAPHTHALENE; APOPTOSIS; MUNICIPAL;
D O I
10.3390/toxins13100691
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Despite the awareness that work in the sewage treatment plant is associated with biological hazards, they have not been fully recognised so far. The research aims to comprehensively evaluate microbiological and toxicological hazards in the air and settled dust in workstations in a sewage treatment plant. The number of microorganisms in the air and settled dust was determined using the culture method and the diversity was evaluated using high-throughput sequencing. Endotoxin concentration was assessed with GC-MS (gas chromatography-mass spectrometry) while secondary metabolites with LC-MS/MS (liquid chromatography coupled to tandem mass spectrometry). Moreover, cytotoxicity of settled dust against a human lung epithelial lung cell line was determined with the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay and UHPLC-Q-ToF-UHRMS (ultra-high-performance liquid chromatography-quadrupole time-of-flight ultrahigh-resolution mass spectrometry) analysis was performed to determine the source of cytotoxicity. The total dust concentration in the sewage treatment plant was low and ranged from 0.030 mg m(-3) to 0.044 mg m(-3). The highest microbiological contamination was observed in sludge thickening building and screenings storage. Three secondary metabolites were detected in the air and sixteen in the settled dust. They were dominated by compounds typical of lichen and plants and Aspergillus, Penicillium and Fusarium genera mould. The settled dust from the sludge thickening building revealed high cytotoxicity to human lung epithelial cells A-549 (IC50 = 6.98 after 72 h). This effect can be attributed to a biocidal compound-didecyldimethylammonium chloride (DDAC-C10) and seven toxic compounds: 4-hydroxynonenal, carbofuran, cerulenin, diethylphosphate, fenpropimorph, naphthalene and onchidal. The presence of DDAC-C10 and other biocidal substances in the sewage treatment plant environment may bring negative results for biological sewage treatment and the natural environment in the future and contribute to microorganisms' increasing antibiotics resistance. Therefore, the concentration of antibiotics, pesticides and disinfectants in sewage treatment plant workstations should be monitored.</p>
引用
收藏
页数:20
相关论文
共 50 条
  • [31] PHYSICOCHEMICAL AND MICROBIOLOGICAL PROPERTIES OF PLANT WASTES TREATED WITH SEWAGE-SLUDGE
    RAJASEKARAN, P
    SAMPATHKUMAR, M
    [J]. AGRICULTURAL WASTES, 1981, 3 (04): : 267 - 275
  • [32] Microbiological and toxicological hazard assessment in a waste sorting plant and proper respiratory protection
    Szulc, Justyna
    Okrasa, Malgorzata
    Majchrzycka, Katarzyna
    Sulyok, Michael
    Nowak, Adriana
    Szponar, Bogumila
    Gorczynska, Anna
    Ryngajllo, Malgorzata
    Gutarowska, Beata
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 303
  • [33] Control of technological devices work in the sewage part of treatment plant on the example of JAMNO sewage treatment plant
    Kozak, Mariusz
    [J]. VIII National Polish Scientific Conference on Complex and Detailed Problems of Environmental Engineering, 2007, (23): : 577 - 597
  • [34] SEWAGE TREATMENT DEGRADATION THERMAL ENERGY MANAGEMENT SYSTEM OF SEWAGE TREATMENT PLANT
    Li, Na
    [J]. THERMAL SCIENCE, 2020, 24 (05): : 3149 - 3156
  • [35] IMPORTANCE OF SEWAGE TREATMENT PLANT RECORDS
    BRILEY, RW
    [J]. SEWAGE AND INDUSTRIAL WASTES, 1958, 30 (03): : 314 - 315
  • [36] Modelling of the BASF Sewage Treatment Plant
    Liebelt, U
    Schmitz, P
    Kern, G
    [J]. CHEMIE INGENIEUR TECHNIK, 2000, 72 (05) : 525 - 528
  • [37] TRAINING FOR SEWAGE TREATMENT PLANT OPERATORS
    HARDENBERGH, WA
    [J]. SEWAGE AND INDUSTRIAL WASTES, 1958, 30 (11): : 1427 - 1431
  • [38] CERTIFICATION OF SEWAGE TREATMENT PLANT OPERATORS
    SHEPHARD, WF
    [J]. SEWAGE WORKS JOURNAL, 1946, 18 (02): : 231 - 237
  • [39] PUTTING A SEWAGE TREATMENT PLANT INTO OPERATION
    BENAS, B
    [J]. TRANSACTIONS OF THE AMERICAN SOCIETY OF CIVIL ENGINEERS, 1954, 119 : 785 - 796
  • [40] Sewage Treatment Plant in Grevenmacher, Luxembourg
    不详
    [J]. Beton- und Stahlbetonbau, 2015, 110 (10) : 671 - 671